A Comprehensive Analysis on the Influence of the Adopted Cumulative Peak Current Distribution in the Assessment of Overhead Lines Lightning Performance

被引:1
|
作者
Conceicao, Daiane [1 ,2 ]
Alipio, Rafael [2 ,3 ]
Lopes, Ivan J. S. [1 ]
Chisholm, William [4 ]
机构
[1] Univ Fed Minas Gerais, Grad Program Elect Engn, Ave Antonio Carlos 6627, BR-31270901 Belo Horizonte, MG, Brazil
[2] CEFET MG Fed Ctr Technol Educ Minas Gerais, Dept Elect Engn, Ave Amazonas,7675 Nova Gameleira, BR-30510000 Belo Horizonte, MG, Brazil
[3] Swiss Fed Inst Technol Lausanne EPFL, Electromagnet Compatibil Lab, CH-1015 Lausanne, Switzerland
[4] Associate METSCO EDM Kinectr, Toronto, ON, Canada
关键词
lightning; backflashover; outage rate; tower footing resistance; cumulative peak-current; attractive distance; LEADER PROGRESSION MODEL; ANALYTICAL REPRESENTATION; ELECTROGEOMETRIC MODEL; TRANSMISSION-LINES; STROKE SIMULATION; SURGE ARRESTERS; EXPOSURE; IMPEDANCE; NETWORKS;
D O I
10.3390/en16155836
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Backflashover rate (BFR) is strongly dependent on the cumulative peak current distribution (CCD) adopted in the calculations. An original aspect of the present work is that such dependence is simultaneously assessed in estimating the probability of the critical current being exceeded as well as in the annual number of flashes to the line. An IEEE brochure recommends that the distribution values that characterize the atmospheric characteristic of the region under study as accurately as possible be used. The objective of this article is to evaluate the impact of the use of different CCDs, related to several measurements carried out around the world, in the estimation of the lightning performance of transmission lines (TLs). Structures of 138, 230 and 500 kV were analyzed. In the simulations, representative curves of lightning associated with measurements taken at Monte San Salvatore (MSS), Morro do Cachimbo (MCS) and TLs in Japan (TLJ) were considered. The distributions recommended by the IEEE and by the CIGRE and the distributions of Berger obtained from MSS, MCS and TLJ were considered. The presented results indicate differences of up to 100% between the considered work distributions and the IEEE one for certain values of tower footing impedance.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Research on comprehensive protections of 10 kV overhead insulated distribution lines from lightning
    Henan Luohe Electric Power Company, Luohe 462001, China
    不详
    Gaodianya Jishu, 2008, 11 (2395-2399):
  • [32] Research on Lightning Overvoltage and Comprehensive lightning proof measures of 10kV Overhead Insulated Distribution Lines
    Han Xuemin
    Mao Minghua
    Wu Jianbin
    Zhou Wenjun
    Yu Jianhui
    Tu jun
    Wang Xiaofeng
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 4035 - +
  • [33] An accurate approach for the evaluation of the performance of overhead distribution lines due to indirect lightning
    Andreotti, Amedeo
    Araneo, Rodolfo
    Mahmood, Farhan
    Pierno, Antonio
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 186
  • [34] Overhead Distribution Lightning Performance on Joint Use Concrete Poles with Transmission Lines
    Nassereddine, M.
    Rizk, J.
    Hellany, A.
    Nagrial, M.
    Nassereddine, G.
    2014 17TH IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE (MELECON), 2014, : 510 - 514
  • [35] Assessment of the Effects of the Electromagnetic Pulse on the Response of Overhead Distribution Lines to Direct Lightning Strikes
    Borghetti, Alberto
    Ishimoto, Kazuyuki
    Napolitano, Fabio
    Nucci, Carlo Alberto
    Tossani, Fabio
    IEEE OPEN ACCESS JOURNAL OF POWER AND ENERGY, 2021, 8 : 522 - 531
  • [36] An expeditious calculation approach to consider the influence of power frequency voltage on the calculation of the lightning performance of transmission lines: Validation for different peak current-front time correlation expressions and cumulative peak current distributions
    Almeida, Frederico S.
    Silveira, Fernando H.
    Visacro, Silverio
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 237
  • [37] Lightning performance on overhead distribution lines: Field observation at West Java']Java - Indonesia
    Zoro, Reynaldo
    Mefiardhi, Ryan
    IPEC: 2005 International Power Engineering Conference, Vols 1 and 2, 2005, : 200 - 205
  • [38] A Survey on Cigre And IEEE Procedures for the Estimation of The Lightning Performance of Overhead Transmission and Distribution Lines
    Nucci, Carlo Alberto
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1124 - 1133
  • [39] Assessment of Lightning Shielding Performance of Double-Circuit UHV Overhead Transmission Lines
    He, Hengxin
    He, Junjia
    Xie, ShiJun
    Yao, Shuai
    Zhang, Dandan
    Dong, Manling
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [40] Performance Against Direct Lightning on 10-kV Overhead Distribution Lines With Counterpoise Wires
    Cao, Jinxin
    Du, Yaping
    Ding, Yuxuan
    Li, Zhe
    Chen, Mingli
    Qi, Ruihan
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2023, 65 (04) : 1108 - 1116