A ceramic-GEM neutron detector with a wide neutron-flux measurement range for the beam monitoring at China spallation neutron source

被引:3
|
作者
Zhu, Lin [1 ,2 ,3 ]
Zhou, Jian-rong [1 ,2 ,3 ]
Zeng, Li-xin [1 ,2 ]
Xiao, Liang
Zhou, Xiao-juan [1 ,2 ]
Tan, Jin-hao [2 ,4 ]
Xia, Yuan-guang [1 ,2 ]
Xu, Hong
Jiang, Xing-fen [1 ,2 ]
Yang, Wen-qin [3 ]
Wang, Yan-feng
Yang, Gui-an [1 ,2 ]
Xie, Yu-guang
Teng, Hai-yun [1 ,2 ]
Li, Jia-jie [1 ,2 ]
Qiu, Yong-xiang
Shen, Pei-xun [1 ,2 ]
Wang, Song-lin
Zhuang, Jian [1 ,2 ,3 ]
Zhao, Yu-bin [1 ,2 ,3 ]
Zhang, Jun-rong [1 ,2 ,3 ]
Sun, Zhi-jia [1 ,2 ,3 ]
Chen, Yuan-bo [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, State Key Lab Particle Detect & Elect, Beijing 100049, Peoples R China
[2] Spallat Neutron Source Sci Ctr, Dongguan 523803, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Harbin Engn Univ, Coll Nucl Sci & Technol, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Electron multipliers (gas); Neutron detectors (cold; thermal; fast neutrons); CASCADE;
D O I
10.1088/1748-0221/18/01/P01033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The increase of neutron flux in pulsed spallation neutron facilities imposes demands on the neutron detector for beam monitoring, including excellent neutron/gamma discrimination, wide dynamic neutron-flux measurement range, wavelength resolution, and long-term stability. In this paper, we developed a ceramic GEM-based (gas electron multiplier) neutron detector with an active area of 100 mm x 100 mm. It adopted a thinner conversion material and the stopping layer to lower the detection efficiency so as to extend the dynamic measurement range of the detector. The detection efficiency of this detector was investigated by the Monte Carlo (MC) tool FLUKA, showing that the low efficiency around 0.01% for 1 Aneutrons was reached by using a 0.1 mu m natB4C converter appended with an aluminum film of 2 mu m thickness. Its validation of the wavelength spectra measurement was verified by comparisons with that made with an LND monitor, and it could work at the condition of 7.1 x 109 n/s for 2.5 Aneutrons. In addition, it was demonstrated that this detector was able to measure the beam profile with a position resolution of better than 2.1 +/- 0.1 mm. The results of simulations and experiments show that this ceramic-GEM neutron detector can meet the requirements of the direct measurement of high-flux beam, and it will be a new neutron detector for the beam monitoring at the China spallation neutron source (CSNS).
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Measurement of the neutron fluence on the spallation source at Dubna
    Adam, J
    Barashenkov, VS
    Ganesan, S
    Golovatiouk, S
    Gupta, SK
    Kailas, S
    Krivopustov, MI
    Kumar, V
    Kumawat, H
    Palsania, HS
    Pronskikh, V
    Sharma, M
    Tsoupko-Sitnikov, VM
    Vladimirova, N
    Westmeier, H
    Westmeier, W
    KERNTECHNIK, 2005, 70 (03) : 127 - 132
  • [42] A sealed ceramic GEM-based neutron detector
    Zhou, Jianjin
    Zhou, Jianrong
    Zhou, Xiaojuan
    Zhu, Lin
    Wei, Yangdong
    Xu, Hong
    Guan, Beiju
    Wu, Huiyin
    Wei, Kang
    Yang, Jianqing
    Wu, Xiaoguang
    Yang, Guian
    Xie, Yuguang
    Zhang, Yi
    Wang, Xiaohu
    Ding, Baowei
    Hu, Bitao
    Sun, Zhijia
    Duan, Limin
    Chen, Yuanbo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 995
  • [43] Detector requirements for the European spallation neutron source ESS
    Gebauer, B
    ADVANCES IN NEUTRON SCATTERING INSTRUMENTATION, 2002, 4785 : 182 - 196
  • [44] The vacuum system of the China spallation neutron source
    Dong, Haiyi
    Song, Hong
    Li, Qi
    Huang, Tao
    Wang, Pengcheng
    Guan, Yuhui
    Liu, Jiaming
    Liu, Shunming
    Tan, Biao
    Ma, Yongsheng
    Sun, Xiaoyang
    Liu, Shenghua
    VACUUM, 2018, 154 : 75 - 81
  • [45] Sample environment at the China spallation neutron source
    Zhang, Shaoying
    Hu, Haitao
    Yuan, Bao
    Bai, Bo
    Luo, Wanju
    Yang, Hua
    Liao, Lijiang
    Shen, Zhongyi
    Huang, Zhiqiang
    Tong, Xin
    JOURNAL OF NEUTRON RESEARCH, 2019, 21 (1-2) : 7 - 15
  • [46] A STUDY OF NEUTRON-FLUX AND SOURCE APPROXIMATIONS IN SLAB GEOMETRY
    WASASTJERNA, F
    NUCLEAR SCIENCE AND ENGINEERING, 1981, 78 (03) : 297 - 304
  • [47] THE DETERMINATION OF SELF-POWERED NEUTRON DETECTOR SENSITIVITY ON THERMAL AND EPITHERMAL NEUTRON-FLUX DENSITIES
    ERBEN, O
    JADERNA ENERGIE, 1980, 26 (02): : 47 - 52
  • [48] Physical design of target station and neutron instruments for China Spallation Neutron Source
    WANG FangWei
    LIANG TianJiao
    YIN Wen
    YU QuanZhi
    HE LunHua
    TAO JuZhou
    ZHU Tao
    JIA XueJun
    ZHANG ShaoYing
    Science China(Physics,Mechanics & Astronomy), 2013, (12) : 2410 - 2424
  • [49] MEASUREMENT OF SPECTRAL NEUTRON-FLUX DENSITY AT BOILING CONDITIONS
    HAGEMANN, U
    MEHNER, HC
    NAGEL, S
    RINDELHARDT, U
    SCHONE, M
    STEPHAN, I
    KRAUSE, F
    ZIEMKE, K
    KERNENERGIE, 1986, 29 (04): : 153 - 156
  • [50] Physical design of target station and neutron instruments for China Spallation Neutron Source
    FangWei Wang
    TianJiao Liang
    Wen Yin
    QuanZhi Yu
    LunHua He
    JuZhou Tao
    Tao Zhu
    XueJun Jia
    ShaoYing Zhang
    Science China Physics, Mechanics and Astronomy, 2013, 56 : 2410 - 2424