A ceramic-GEM neutron detector with a wide neutron-flux measurement range for the beam monitoring at China spallation neutron source

被引:3
|
作者
Zhu, Lin [1 ,2 ,3 ]
Zhou, Jian-rong [1 ,2 ,3 ]
Zeng, Li-xin [1 ,2 ]
Xiao, Liang
Zhou, Xiao-juan [1 ,2 ]
Tan, Jin-hao [2 ,4 ]
Xia, Yuan-guang [1 ,2 ]
Xu, Hong
Jiang, Xing-fen [1 ,2 ]
Yang, Wen-qin [3 ]
Wang, Yan-feng
Yang, Gui-an [1 ,2 ]
Xie, Yu-guang
Teng, Hai-yun [1 ,2 ]
Li, Jia-jie [1 ,2 ]
Qiu, Yong-xiang
Shen, Pei-xun [1 ,2 ]
Wang, Song-lin
Zhuang, Jian [1 ,2 ,3 ]
Zhao, Yu-bin [1 ,2 ,3 ]
Zhang, Jun-rong [1 ,2 ,3 ]
Sun, Zhi-jia [1 ,2 ,3 ]
Chen, Yuan-bo [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, State Key Lab Particle Detect & Elect, Beijing 100049, Peoples R China
[2] Spallat Neutron Source Sci Ctr, Dongguan 523803, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Harbin Engn Univ, Coll Nucl Sci & Technol, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Electron multipliers (gas); Neutron detectors (cold; thermal; fast neutrons); CASCADE;
D O I
10.1088/1748-0221/18/01/P01033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The increase of neutron flux in pulsed spallation neutron facilities imposes demands on the neutron detector for beam monitoring, including excellent neutron/gamma discrimination, wide dynamic neutron-flux measurement range, wavelength resolution, and long-term stability. In this paper, we developed a ceramic GEM-based (gas electron multiplier) neutron detector with an active area of 100 mm x 100 mm. It adopted a thinner conversion material and the stopping layer to lower the detection efficiency so as to extend the dynamic measurement range of the detector. The detection efficiency of this detector was investigated by the Monte Carlo (MC) tool FLUKA, showing that the low efficiency around 0.01% for 1 Aneutrons was reached by using a 0.1 mu m natB4C converter appended with an aluminum film of 2 mu m thickness. Its validation of the wavelength spectra measurement was verified by comparisons with that made with an LND monitor, and it could work at the condition of 7.1 x 109 n/s for 2.5 Aneutrons. In addition, it was demonstrated that this detector was able to measure the beam profile with a position resolution of better than 2.1 +/- 0.1 mm. The results of simulations and experiments show that this ceramic-GEM neutron detector can meet the requirements of the direct measurement of high-flux beam, and it will be a new neutron detector for the beam monitoring at the China spallation neutron source (CSNS).
引用
收藏
页数:15
相关论文
共 50 条
  • [21] NEUTRON-FLUX DISTRIBUTION AND AVERAGE NEUTRON-FLUX DENSITY COMPUTED IN CAVITY SPACE OF A AM-241-BE NEUTRON SOURCE OF ANNULAR SHAPE
    VANSKA, RA
    BLOMSTER, KA
    RIEPPO, RM
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1975, 26 (6-7): : 399 - 401
  • [22] A WIDE-RANGE NEUTRON DETECTOR AND MONITORING INSTRUMENT
    PORGES, KGA
    KLIPPERT, TE
    NUCLEAR SCIENCE AND ENGINEERING, 1960, 7 (02) : 147 - 155
  • [23] Shielding for neutron beam extraction pipes of Chinese Spallation Neutron Source
    Zhang, Bin
    Chen, Yi-Xue
    Yang, Shou-Hai
    Yin, Wen
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (02): : 210 - 214
  • [24] Online monitoring of air activation at the China spallation neutron source
    Zhuang, Sixuan
    Wu, Qingbiao
    Wang, Yufei
    Ma, Yinglin
    Li, Lun
    Zhang, Gang
    Chen, Yu
    Zhang, Yuliang
    Liu, Huachang
    Qi, Xin
    Zhao, Luyang
    Ma, Hongbo
    Journal of Environmental Radioactivity, 2021, 234
  • [25] Online monitoring of air activation at the China spallation neutron source
    Zhuang, Sixuan
    Wu, Qingbiao
    Wang, Yufei
    Ma, Yinglin
    Li, Lun
    Zhang, Gang
    Chen, Yu
    Zhang, Yuliang
    Liu, Huachang
    Qi, Xin
    Zhao, Luyang
    Ma, Hongbo
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2021, 234
  • [26] A hemispherical fission chamber for the neutron-flux monitoring
    Parzhitskii, SS
    Kobzev, AP
    Popov, YP
    Gundorin, NA
    Oprya, IA
    Voinov, AV
    Buklanov, GV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2004, 47 (01) : 36 - 38
  • [27] Precision neutron flux measurement with a neutron beam monitor
    Ino, T.
    Otono, H.
    Mishima, K.
    Yamada, T.
    INTERNATIONAL WORKSHOP ON NEUTRON OPTICS AND DETECTORS (NOP&D 2013), 2014, 528
  • [28] DIRECT MEASUREMENT OF MECHANICAL MOMENTUM OF A NEUTRON-FLUX
    VOINOV, AM
    KOSHELEV, AS
    ODINTSOV, YM
    PAVLOVSKII, AI
    POPOV, VA
    RODIGIN, VN
    SOVIET ATOMIC ENERGY, 1989, 66 (01): : 62 - 64
  • [29] A Hemispherical Fission Chamber for the Neutron-Flux Monitoring
    S. S. Parzhitskii
    A. P. Kobzev
    Yu. P. Popov
    N. A. Gundorin
    I. A. Oprya
    A. V. Voinov
    G. V. Buklanov
    Instruments and Experimental Techniques, 2004, 47 : 36 - 38
  • [30] Cross section measurement of neutron capture reaction based on back-streaming white neutron source at China spallation neutron source
    Zhang Qi-Wei
    Luan Guang-Yuan
    Ren Jie
    Ruan Xi-Chao
    He Guo-Zhu
    Bao Jie
    Sun Qi
    Huang Han-Xiong
    Wang Zhao-Hui
    Gu Min-Hao
    Yu Tao
    Xie Li-Kun
    Chen Yong-Hao
    An Qi
    Bai Huai-Yong
    Bao Yu
    Cao Ping
    Chen Hao-Lei
    Chen Qi-Ping
    Chen Yu-Kai
    Chen Zhen
    Cui Zeng-Qi
    Fan Rui-Rui
    Feng Chang-Qing
    Gao Ke-Qing
    Han Chang-Cai
    Han Zi-Jie
    He Yong-Cheng
    Hong Yang
    Huang Wei-Ling
    Huang Xi-Ru
    Ji Xiao-Lu
    Ji Xu-Yang
    Jiang Wei
    Jiang Hao-Yu
    Jiang Zhi-Jie
    Jing Han-Tao
    Kang Ling
    Kang Ming-Tao
    Li Bo
    Li Chao
    Li Jia-Wen
    Li Lun
    Li Qiang
    Li Xiao
    Li Yang
    Liu Rong
    Liu Shu-Bin
    Liu Xing-Yan
    Mu Qi-Li
    ACTA PHYSICA SINICA, 2021, 70 (22)