A ceramic-GEM neutron detector with a wide neutron-flux measurement range for the beam monitoring at China spallation neutron source

被引:3
|
作者
Zhu, Lin [1 ,2 ,3 ]
Zhou, Jian-rong [1 ,2 ,3 ]
Zeng, Li-xin [1 ,2 ]
Xiao, Liang
Zhou, Xiao-juan [1 ,2 ]
Tan, Jin-hao [2 ,4 ]
Xia, Yuan-guang [1 ,2 ]
Xu, Hong
Jiang, Xing-fen [1 ,2 ]
Yang, Wen-qin [3 ]
Wang, Yan-feng
Yang, Gui-an [1 ,2 ]
Xie, Yu-guang
Teng, Hai-yun [1 ,2 ]
Li, Jia-jie [1 ,2 ]
Qiu, Yong-xiang
Shen, Pei-xun [1 ,2 ]
Wang, Song-lin
Zhuang, Jian [1 ,2 ,3 ]
Zhao, Yu-bin [1 ,2 ,3 ]
Zhang, Jun-rong [1 ,2 ,3 ]
Sun, Zhi-jia [1 ,2 ,3 ]
Chen, Yuan-bo [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, State Key Lab Particle Detect & Elect, Beijing 100049, Peoples R China
[2] Spallat Neutron Source Sci Ctr, Dongguan 523803, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Harbin Engn Univ, Coll Nucl Sci & Technol, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Electron multipliers (gas); Neutron detectors (cold; thermal; fast neutrons); CASCADE;
D O I
10.1088/1748-0221/18/01/P01033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The increase of neutron flux in pulsed spallation neutron facilities imposes demands on the neutron detector for beam monitoring, including excellent neutron/gamma discrimination, wide dynamic neutron-flux measurement range, wavelength resolution, and long-term stability. In this paper, we developed a ceramic GEM-based (gas electron multiplier) neutron detector with an active area of 100 mm x 100 mm. It adopted a thinner conversion material and the stopping layer to lower the detection efficiency so as to extend the dynamic measurement range of the detector. The detection efficiency of this detector was investigated by the Monte Carlo (MC) tool FLUKA, showing that the low efficiency around 0.01% for 1 Aneutrons was reached by using a 0.1 mu m natB4C converter appended with an aluminum film of 2 mu m thickness. Its validation of the wavelength spectra measurement was verified by comparisons with that made with an LND monitor, and it could work at the condition of 7.1 x 109 n/s for 2.5 Aneutrons. In addition, it was demonstrated that this detector was able to measure the beam profile with a position resolution of better than 2.1 +/- 0.1 mm. The results of simulations and experiments show that this ceramic-GEM neutron detector can meet the requirements of the direct measurement of high-flux beam, and it will be a new neutron detector for the beam monitoring at the China spallation neutron source (CSNS).
引用
收藏
页数:15
相关论文
共 50 条
  • [31] The development of a 6Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source
    Chong, Su-Ann
    Riedel, Richard
    Funk, Loren
    Visscher, Theodore
    Donahue, Cornelius
    Hannan, Bruce
    Montcalm, Christopher
    Beal, Justin
    Hayward, Jason
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1039
  • [32] High efficiency neutron detector for low neutron flux measurement
    Waheed A.
    Aqil-Ur-Rahman
    Zakaullah M.
    Murtaza G.
    Journal of Fusion Energy, 2000, 19 (1) : 91 - 92
  • [33] Beam dump optics for the spallation neutron source
    Raparia, D
    Lee, YY
    Wei, J
    Henderson, S
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 3416 - 3418
  • [34] Neutron Beam Monitors for the European Spallation Source
    Khaplanov, A.
    Anastasopoulos, M.
    Bentley, P. M.
    Hall-Wilton, R.
    Kanaki, K.
    Kirstein, O.
    Nilsson, E.
    Piscitelli, F.
    Stefanescu, I.
    Sutton, I.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [35] Beam transfer lines for the spallation neutron source
    Raparia, D
    Lee, YY
    Weng, WT
    Wei, J
    HIGH INTENSITY AND HIGH BRIGHTNESS HADRON BEAMS, 2002, 642 : 130 - 132
  • [36] GAMBE: Thermal Neutron Detector for Directional Measurement of Neutron Flux
    Ahmed, A.
    Burdin, S.
    Casse, G.
    van Zalinge, H.
    Powel, S.
    Rees, J.
    Smith, A.
    Tsurin, I.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [37] High efficiency neutron detector for low neutron flux measurement
    Waheed, A
    Aqil-ur-Rahman
    Zakaullah, M
    Murtaza, G
    JOURNAL OF FUSION ENERGY, 2000, 19 (01) : 91 - 92
  • [38] Beam dynamics in the spallation neutron source linac
    Jeon, D
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 107 - 111
  • [39] Study on Injection Beam Loss for China Spallation Neutron Source Accelerator
    Huang M.
    Xu S.
    Lu X.
    Wang S.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (09): : 1708 - 1714
  • [40] Terrestrial neutron induced failure rate measurement of SiC MOSFETs using China spallation neutron source
    Peng, Chao
    Lei, Zhifeng
    Zhang, Zhangang
    He, Yujuan
    Ma, Teng
    Huang, Yun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2023, 540 : 129 - 135