Diagnostic Value of Carotid Plaque Assessment with AIS Based on Quantitative Parameters of Dual-Layer Detector Spectral CT

被引:0
|
作者
Meng, Xiaoying [1 ]
Li, Fei [1 ]
Wu, Wenpei [2 ]
Wu, Juncang [1 ,3 ]
机构
[1] Anhui Med Univ, Hefei Hosp, Hefei Peoples Hosp 2, Dept Neurol, Hefei 230011, Anhui, Peoples R China
[2] Anhui Med Univ, Clin Sch Med 5, Hefei 230032, Anhui, Peoples R China
[3] Bengbu Med Coll, Hefei Peoples Hosp 2, Dept Neurol, Hefei 230011, Anhui, Peoples R China
关键词
ischemic stroke; carotid plaque; spectral CT; effective atomic number; iodine density values; anhydrous iodine values; electron density; ISCHEMIC-STROKE; RISK-FACTORS; ENERGY CT; MATRIX-METALLOPROTEINASE-9; LESIONS; BURDEN; ARTERY;
D O I
10.2147/IJGM.S448852
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To investigate the quantitative assessment of carotid plaque by each parameter of dual-layer detector spectral CT and its diagnostic value in patients with acute cerebral infarction. Patients and Methods: Eighty-three patients with carotid atherosclerotic plaques who underwent spectral CT scanning were retrospectively included. Forty-two patients with acute ischaemic stroke (AIS) were included in the study group, and 41 patients without AIS were included in the control group. We compared the detection of carotid plaques in the two groups and the differences in the spectral quantitative parameters of the plaques in the two groups, and their diagnostic efficacy was obtained. Results: The detection rate of carotid plaques in the AIS group was higher than that in the non-AIS group (p<0.05); the carotid plaques in the AIS group mainly consisted of non-calcified plaques, while those in the non-AIS group mainly consisted of calcified plaques. The effective atomic number (Zeff), slope of the energy spectrum curve (lambda H), electron density (ED), and iodine-no-water value of the carotid plaques in the AIS group were lower than those in the non-AIS (p<0.05). For the differentiation of the carotid plaques in the AIS group from those in the non-AIS group, the area under the curve (AUC) of Zeff amounted to 0.637 (cut-off value: 11.865; sensitivity: 72.5%; specificity: 56.2%), the AUC of lambda H amounted to 0.628 (cut-off value: 19.56; sensitivity: 76.3%; specificity: 51.6%), and that for ED amounted to 0.624 (cut-off value: 110.45; sensitivity: 60.0%; specificity: 64.1%), AUC of iodine-no-water value amounted to 0.645 (cut-off value: 9.125; sensitivity: 61.3%; specificity: 65.6%). Conclusion: In summary, the quantitative parameters of dual-layer detector spectral CT can be used to assess plaque stability and have certain value in the diagnosis of AIS. The quantitative parameters can effectively differentiate carotid plaques in AIS and non-AIS patients.
引用
收藏
页码:1263 / 1272
页数:10
相关论文
共 50 条
  • [21] Detector-based spectral CT with a novel dual-layer technology: principles and applications
    Negin Rassouli
    Maryam Etesami
    Amar Dhanantwari
    Prabhakar Rajiah
    Insights into Imaging, 2017, 8 : 589 - 598
  • [22] Objective image characterization of a spectral CT scanner with dual-layer detector
    Ozguner, Orhan
    Dhanantwari, Amar
    Halliburton, Sandra
    Wen, Gezheng
    Utrup, Steven
    Jordan, David
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02):
  • [23] The Application of Dual-layer Spectral Detector CT in Abdominal Vascular Imaging
    Lai, Lu-Yao
    Jiang, Ying
    Shu, Jian
    CURRENT MEDICAL IMAGING, 2023, 19 (14) : 1609 - 1615
  • [24] Value of dual-layer spectral detector CT in diagnosing regional lymph node metastasis of colorectal cancer
    陈琰
    ChinaMedicalAbstracts(InternalMedicine), 2022, 39 (01) : 2 - 2
  • [25] SNR performance comparison of dual-layer detector and dual-kVp spectral CT
    Heismann, B. J.
    Wirth, S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3820 - 3822
  • [26] Quantitative Assessment of Radiologically Indeterminate Local Colonic Wall Thickening on Iodine Density Images Using Dual-Layer Spectral Detector CT
    Wang, Guorong
    Fang, Yue
    Wang, Zhiwei
    Jin, Zhengyu
    ACADEMIC RADIOLOGY, 2021, 28 (10) : 1368 - 1374
  • [27] The diagnostic performance of dual-layer spectral detector CT for distinguishing breast cancer biomarker expression and molecular subtypes
    Lanjing Chen
    Zhengyuan Xiao
    Jianmei Fu
    Jingrong Huang
    Yongshu Lan
    Scientific Reports, 14
  • [28] The diagnostic performance of dual-layer spectral detector CT for distinguishing breast cancer biomarker expression and molecular subtypes
    Chen, Lanjing
    Xiao, Zhengyuan
    Fu, Jianmei
    Huang, Jingrong
    Lan, Yongshu
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [29] Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading
    Mu, Ronghua
    Meng, Zhuoni
    Guo, Zixuan
    Qin, Xiaoyan
    Huang, Guangyi
    Yang, Xuri
    Jin, Hui
    Yang, Peng
    Zhang, Xiaodi
    Zhu, Xiqi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, : 4601 - 4611
  • [30] The diagnostic value of dual-layer CT in the assessment of lymph nodes in lymphoma patients with PET/CT as a reference standard
    Tan, Zhengwu
    Mei, Heng
    Qin, Chunxia
    Zhang, Xiao
    Yang, Ming
    Zhang, Lan
    Wang, Jing
    SCIENTIFIC REPORTS, 2023, 13 (01)