Diagnostic Value of Carotid Plaque Assessment with AIS Based on Quantitative Parameters of Dual-Layer Detector Spectral CT

被引:0
|
作者
Meng, Xiaoying [1 ]
Li, Fei [1 ]
Wu, Wenpei [2 ]
Wu, Juncang [1 ,3 ]
机构
[1] Anhui Med Univ, Hefei Hosp, Hefei Peoples Hosp 2, Dept Neurol, Hefei 230011, Anhui, Peoples R China
[2] Anhui Med Univ, Clin Sch Med 5, Hefei 230032, Anhui, Peoples R China
[3] Bengbu Med Coll, Hefei Peoples Hosp 2, Dept Neurol, Hefei 230011, Anhui, Peoples R China
关键词
ischemic stroke; carotid plaque; spectral CT; effective atomic number; iodine density values; anhydrous iodine values; electron density; ISCHEMIC-STROKE; RISK-FACTORS; ENERGY CT; MATRIX-METALLOPROTEINASE-9; LESIONS; BURDEN; ARTERY;
D O I
10.2147/IJGM.S448852
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To investigate the quantitative assessment of carotid plaque by each parameter of dual-layer detector spectral CT and its diagnostic value in patients with acute cerebral infarction. Patients and Methods: Eighty-three patients with carotid atherosclerotic plaques who underwent spectral CT scanning were retrospectively included. Forty-two patients with acute ischaemic stroke (AIS) were included in the study group, and 41 patients without AIS were included in the control group. We compared the detection of carotid plaques in the two groups and the differences in the spectral quantitative parameters of the plaques in the two groups, and their diagnostic efficacy was obtained. Results: The detection rate of carotid plaques in the AIS group was higher than that in the non-AIS group (p<0.05); the carotid plaques in the AIS group mainly consisted of non-calcified plaques, while those in the non-AIS group mainly consisted of calcified plaques. The effective atomic number (Zeff), slope of the energy spectrum curve (lambda H), electron density (ED), and iodine-no-water value of the carotid plaques in the AIS group were lower than those in the non-AIS (p<0.05). For the differentiation of the carotid plaques in the AIS group from those in the non-AIS group, the area under the curve (AUC) of Zeff amounted to 0.637 (cut-off value: 11.865; sensitivity: 72.5%; specificity: 56.2%), the AUC of lambda H amounted to 0.628 (cut-off value: 19.56; sensitivity: 76.3%; specificity: 51.6%), and that for ED amounted to 0.624 (cut-off value: 110.45; sensitivity: 60.0%; specificity: 64.1%), AUC of iodine-no-water value amounted to 0.645 (cut-off value: 9.125; sensitivity: 61.3%; specificity: 65.6%). Conclusion: In summary, the quantitative parameters of dual-layer detector spectral CT can be used to assess plaque stability and have certain value in the diagnosis of AIS. The quantitative parameters can effectively differentiate carotid plaques in AIS and non-AIS patients.
引用
收藏
页码:1263 / 1272
页数:10
相关论文
共 50 条
  • [1] The diagnostic value of quantitative parameters on dual-layer detector-based spectral CT in identifying ischaemic stroke
    Huang, Jian
    Chen, Jinghua
    Wang, Ximing
    Hao, Ling
    Zhang, Jinfeng
    Zhang, Xiaohui
    Sheng, Zhihong
    Liu, Kefu
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [2] Quantitative calcium-based assessment of osteoporosis in dual-layer spectral CT
    Do, T. D.
    Rahn, S.
    Melzig, C.
    Heussel, C. P.
    Stiller, W.
    Kauczor, H. U.
    Weber, T. F.
    Skornitzke, S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 178
  • [4] Noninvasive assessment of liver fibrosis by dual-layer spectral detector CT
    Morita, Koichiro
    Nishie, Akihiro
    Ushijima, Yasuhiro
    Takayama, Yukihisa
    Fujita, Nobuhiro
    Kubo, Yuichiro
    Ishimatsu, Keisuke
    Yoshizumi, Tomoharu
    Maehara, Junki
    Ishigami, Kousei
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [5] Iodine Imaging at Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Dhanantwari, A.
    Halliburton, S.
    Wen, G.
    Utrup, S.
    Jordan, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3657 - 3657
  • [6] Diagnostic value of dual-layer spectral detector CT parameters for differentiating high- from low-grade bladder cancer
    Chen, Li
    Xu, Lili
    Zhang, Xiaoxiao
    Zhang, Jiahui
    Bai, Xin
    Peng, Qianyu
    Guo, Erjia
    Lu, Xiaomei
    Yu, Shenghui
    Jin, Zhengyu
    Zhang, Gumuyang
    Xie, Yi
    Xue, Huadan
    Sun, Hao
    INSIGHTS INTO IMAGING, 2025, 16 (01):
  • [7] Diagnostic value of dual-layer spectral detector CT in differentiating lung adenocarcinoma from squamous cell carcinoma
    Mu, Ronghua
    Meng, Zhuoni
    Guo, Zixuan
    Qin, Xiaoyan
    Huang, Guangyi
    Yang, Xuri
    Jin, Hui
    Yang, Peng
    Deng, Meimei
    Zhang, Xiaodi
    Zhu, Xiqi
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [8] The diagnostic value of second-generation dual-layer spectral detector CT for Stanford type A aortic dissection
    Tan, Cong
    Gui, Shen
    Zhong, Zhilin
    Chen, Xianfeng
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (11) : e261 - e261
  • [9] Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT
    S. C. Brandelik
    S. Skornitzke
    T. Mokry
    S. Sauer
    W. Stiller
    J. Nattenmüller
    H. U. Kauczor
    T. F. Weber
    T. D. Do
    European Radiology, 2021, 31 : 7664 - 7673
  • [10] Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT
    Brandelik, S. C.
    Skornitzke, S.
    Mokry, T.
    Sauer, S.
    Stiller, W.
    Nattenmuller, J.
    Kauczor, H. U.
    Weber, T. F.
    Do, T. D.
    EUROPEAN RADIOLOGY, 2021, 31 (10) : 7664 - 7673