Multilevel Venous Obstruction in Patients with Cardiac Implantable Electronic Devices

被引:1
|
作者
Czajkowski, Marek [1 ]
Polewczyk, Anna [2 ,3 ]
Jachec, Wojciech [4 ]
Kosior, Jaroslaw [5 ]
Nowosielecka, Dorota [6 ]
Tulecki, Lukasz [7 ]
Stefanczyk, Pawel [6 ]
Kutarski, Andrzej [8 ]
机构
[1] Med Univ Lublin, Dept Cardiac Surg, PL-20059 Lublin, Poland
[2] Jan Kochanowski Univ, Inst Med Sci, PL-25317 Kielce, Poland
[3] Swietokrzyskie Ctr Cardiol, Dept Cardiac Surg, PL-25736 Kielce, Poland
[4] Med Univ Silesia, Fac Med Sci Zabrze, Dept Cardiol 2, PL-41800 Zabrze, Poland
[5] Masovian Specialist Hosp Radom, Dept Cardiol, PL-26617 Radom, Poland
[6] Pope John Paul II Prov Hosp Zamosc, Dept Cardiol, PL-22400 Zamosc, Poland
[7] Pope John Paul II Prov Hosp Zamosc, Dept Cardiac Surg, PL-22400 Zamosc, Poland
[8] Med Univ Lublin, Dept Cardiol, Lublin, Poland
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 02期
关键词
multilevel lead-related venous obstruction; risk factors; transvenous lead extraction; complications; long-term survival; EXPERT CONSENSUS STATEMENT; RISK-FACTORS; LEAD EXTRACTION; CARDIOVERTER-DEFIBRILLATOR; TERM THROMBOSIS; SUBCLAVIAN VEIN; PACEMAKER; OCCLUSION; PREVALENCE; REVISION;
D O I
10.3390/medicina60020336
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: The nature of multilevel lead-related venous stenosis/occlusion (MLVSO) and its influence on transvenous lead extraction (TLE) as well as long-term survival remains poorly understood. Materials and Methods: A total of 3002 venograms obtained before a TLE were analyzed to identify the risk factors for MLVSO, as well as the procedure effectiveness and long-term survival. Results: An older patient age at the first system implantation (OR = 1.015; p < 0.001), the number of leads in the heart (OR = 1.556; p < 0.001), the placement of the coronary sinus (CS) lead (OR = 1.270; p = 0.027), leads on both sides of the chest (OR = 7.203; p < 0.001), and a previous device upgrade or downgrade with lead abandonment (OR = 2.298; p < 0.001) were the strongest predictors of MLVSO. Conclusions: The presence of MLVSO predisposes patients with cardiac implantable electronic devices (CIED) to the development of infectious complications. Patients with multiple narrowed veins are likely to undergo longer and more complex procedures with complications, and the rates of clinical and procedural success are lower in this group. Long-term survival after a TLE is similar in patients with MLVSO and those without venous obstruction. MLVSO probably better depicts the severity of global venous obstruction than the degree of vein narrowing at only one point.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Innovations in Cardiac Implantable Electronic Devices
    Khan, Khurrum
    Kim, Jitae A.
    Gurgu, Andra
    Khawaja, Muzamil
    Cozma, Dragos
    Chelu, Mihail G.
    CARDIOVASCULAR DRUGS AND THERAPY, 2022, 36 (04) : 763 - 775
  • [22] Cybersecurity and cardiac implantable electronic devices
    Bryce Alexander
    Adrian Baranchuk
    Nature Reviews Cardiology, 2020, 17 : 315 - 317
  • [23] Magnetic resonance imaging in patients with cardiac implantable electronic devices
    Maass, A. H.
    Hemels, M. E. W.
    Allaart, C. P.
    NETHERLANDS HEART JOURNAL, 2018, 26 (12) : 584 - 590
  • [24] Considerations in Patients With Cardiac Implantable Electronic Devices at End of Life
    Gura, Melanie T.
    AACN ADVANCED CRITICAL CARE, 2015, 26 (04) : 356 - 363
  • [25] THE SAFETY OF MRI IN PATIENTS WITH HYBRID CARDIAC IMPLANTABLE ELECTRONIC DEVICES
    Liu, Michael
    Pannunzio, Sofia
    Minaskeian, Nareg
    Klooster, Lindsay
    Sorajja, Dan
    Scott, Luis
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 245 - 245
  • [26] Recommendations for Imaging Patients With Cardiac Implantable Electronic Devices (CIEDs)
    Vigen, Karl K.
    Reeder, Scott B.
    Hood, Maureen N.
    Steckner, Michael
    Leiner, Tim
    Dombroski, David A.
    Gulani, Vikas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (05) : 1311 - 1317
  • [27] Magnetic resonance imaging in patients with cardiac implantable electronic devices
    A. H. Maass
    M. E. W. Hemels
    C. P. Allaart
    Netherlands Heart Journal, 2018, 26 : 584 - 590
  • [28] Cardiac implantable electronic devices and cybersecurity
    Patel, Bhakti
    Makaryus, Amgad N.
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (18) : 69 - 77
  • [29] Innovations in Cardiac Implantable Electronic Devices
    Khurrum Khan
    Jitae A. Kim
    Andra Gurgu
    Muzamil Khawaja
    Dragos Cozma
    Mihail G. Chelu
    Cardiovascular Drugs and Therapy, 2022, 36 : 763 - 775
  • [30] Is air travel safe for patients with cardiac implantable electronic devices?
    Erkan, Aycan Fahri
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2021, 25 : S26 - S28