Multilevel Venous Obstruction in Patients with Cardiac Implantable Electronic Devices

被引:1
|
作者
Czajkowski, Marek [1 ]
Polewczyk, Anna [2 ,3 ]
Jachec, Wojciech [4 ]
Kosior, Jaroslaw [5 ]
Nowosielecka, Dorota [6 ]
Tulecki, Lukasz [7 ]
Stefanczyk, Pawel [6 ]
Kutarski, Andrzej [8 ]
机构
[1] Med Univ Lublin, Dept Cardiac Surg, PL-20059 Lublin, Poland
[2] Jan Kochanowski Univ, Inst Med Sci, PL-25317 Kielce, Poland
[3] Swietokrzyskie Ctr Cardiol, Dept Cardiac Surg, PL-25736 Kielce, Poland
[4] Med Univ Silesia, Fac Med Sci Zabrze, Dept Cardiol 2, PL-41800 Zabrze, Poland
[5] Masovian Specialist Hosp Radom, Dept Cardiol, PL-26617 Radom, Poland
[6] Pope John Paul II Prov Hosp Zamosc, Dept Cardiol, PL-22400 Zamosc, Poland
[7] Pope John Paul II Prov Hosp Zamosc, Dept Cardiac Surg, PL-22400 Zamosc, Poland
[8] Med Univ Lublin, Dept Cardiol, Lublin, Poland
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 02期
关键词
multilevel lead-related venous obstruction; risk factors; transvenous lead extraction; complications; long-term survival; EXPERT CONSENSUS STATEMENT; RISK-FACTORS; LEAD EXTRACTION; CARDIOVERTER-DEFIBRILLATOR; TERM THROMBOSIS; SUBCLAVIAN VEIN; PACEMAKER; OCCLUSION; PREVALENCE; REVISION;
D O I
10.3390/medicina60020336
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: The nature of multilevel lead-related venous stenosis/occlusion (MLVSO) and its influence on transvenous lead extraction (TLE) as well as long-term survival remains poorly understood. Materials and Methods: A total of 3002 venograms obtained before a TLE were analyzed to identify the risk factors for MLVSO, as well as the procedure effectiveness and long-term survival. Results: An older patient age at the first system implantation (OR = 1.015; p < 0.001), the number of leads in the heart (OR = 1.556; p < 0.001), the placement of the coronary sinus (CS) lead (OR = 1.270; p = 0.027), leads on both sides of the chest (OR = 7.203; p < 0.001), and a previous device upgrade or downgrade with lead abandonment (OR = 2.298; p < 0.001) were the strongest predictors of MLVSO. Conclusions: The presence of MLVSO predisposes patients with cardiac implantable electronic devices (CIED) to the development of infectious complications. Patients with multiple narrowed veins are likely to undergo longer and more complex procedures with complications, and the rates of clinical and procedural success are lower in this group. Long-term survival after a TLE is similar in patients with MLVSO and those without venous obstruction. MLVSO probably better depicts the severity of global venous obstruction than the degree of vein narrowing at only one point.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Treatment with cardiac electronic implantable devices
    Kuschyk, Juergen
    Sattler, Katherine
    Fastenrath, Fabian
    Rudic, Boris
    Akin, Ibrahim
    HERZ, 2024, 49 (03) : 233 - 246
  • [42] Lead complications after cardiac surgery in patients with cardiac implantable electronic devices
    Frausing, Maria Hee Jung Park
    Nielsen, Jens Cosedis
    Johansen, Jens Brock
    Jorgensen, Ole Dan
    Kristensen, Jens
    Olsen, Thomas
    Gerdes, Christian
    Kronborg, Mads Brix
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 62 (02)
  • [43] Cardiac Magnetic Resonance in Patients With Cardiac Implantable Electronic Devices Challenges and Solutions
    Rajiah, Prabhakar
    Kay, Fernando
    Bolen, Michael
    Patel, Amit R.
    Landeras, Luis
    JOURNAL OF THORACIC IMAGING, 2020, 35 (01) : W1 - W17
  • [44] Cardiac implantable electronic devices in end-stage renal disease patients: preservation of central venous circulation
    Lopera, Gustavo
    Beathard, Gerald A.
    Exaire, Jose
    Carrillo, Roger
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (01) : 101 - 104
  • [45] Cardiac implantable electronic devices in end-stage renal disease patients: preservation of central venous circulation
    Gustavo Lopera
    Gerald A. Beathard
    Jose Exaire
    Roger Carrillo
    Journal of Interventional Cardiac Electrophysiology, 2012, 34 : 101 - 104
  • [46] Letter: "Assessment of Association Between Venous Occlusion and Infection of Cardiac Implantable Electronic Devices"
    Cheema, Muhammad Rafay Shahzad
    ANGIOLOGY, 2023, 74 (10) : 1001 - 1001
  • [47] Advances in implantable cardiac electronic devices and cardiac electrophysiology
    Denniss, Alan Robert
    Davis, Lloyd M.
    Sanders, Prashanthan
    HEART LUNG AND CIRCULATION, 2012, 21 (6-7): : 309 - 310
  • [48] Radiotherapy in patients with cardiac implantable electronic devices: clinical and dosimetric aspects
    Riva, G.
    Alessandro, O.
    Spoto, R.
    Ferrari, A.
    Garibaldi, C.
    Cattani, F.
    Colombo, N.
    Giovenzana, F. L. F.
    Cipolla, C.
    Winnick, M.
    Persiani, M.
    Castelluccia, F.
    Fiore, M. Sarra
    Orecchia, R.
    Jereczek-Fossa, B. A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S445 - S446
  • [49] Radiotherapy in patients with cardiac implantable electronic devices: clinical and dosimetric aspects
    Giulia Riva
    Ombretta Alessandro
    Ruggero Spoto
    Annamaria Ferrari
    Cristina Garibaldi
    Federica Cattani
    Rosa Luraschi
    Elena Rondi
    Nicola Colombo
    Fulvio Lorenzo Francesco Giovenzana
    Carlo Maria Cipolla
    Mikolaj Winnicki
    Martina Persiani
    Fabiana Castelluccia
    Massimo Sarra Fiore
    Roberto Orecchia
    Barbara Alicja Jereczek-Fossa
    Medical Oncology, 2018, 35
  • [50] The use of remote monitoring of patients with cardiac implantable electronic devices in Poland
    Tajstra, Mateusz
    Dyrbus, Maciej
    Grabowski, Marcin
    Rokicki, Jakub K.
    Nowak, Marcin
    Gasior, Mariusz
    KARDIOLOGIA POLSKA, 2022, 80 (04) : 479 - 481