Biomechanical Analysis of Cortical Bone Trajectory Screw Versus Bone Cement Screw for Fixation in Porcine Spinal Low Bone Mass Model

被引:2
|
作者
Li, Yifan [1 ]
Wang, Silian [2 ]
Zhu, Zhenbiao [4 ]
Chen, Liwei [2 ]
Shi, Zhangpeng [3 ]
Ye, Xiaojian [1 ]
Xu, Wei [1 ]
Li, Zhikun [1 ,5 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Orthoped, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Tongren Hosp, Sch Med, Dept Imaging, Shanghai, Peoples R China
[3] Anhui Med Univ, Shanghai Clin Coll, Shanghai, Peoples R China
[4] Cent South Univ, Dept Orthopaed, Xiangya Sch Med, Affiliated Haikou Hosp, Haikou, Hainan, Peoples R China
[5] Shanghai Tongren Hosp, Shanghai, Peoples R China
来源
CLINICAL SPINE SURGERY | 2023年 / 36卷 / 04期
关键词
cortical bone trajectory screw; bone cement screw; biomechanical analysis; porcine spinal model; PEDICLE; AUGMENTATION; PLACEMENT; ADJACENT;
D O I
10.1097/BSD.0000000000001395
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: A prospective study of in vitro animal. Objection: To compare the biomechanics of cortical bone trajectory screw (CBT) and bone cement screw (BC) in an isolated porcine spinal low bone mass model. Summary of Background Data: The choice of spinal fixation in patients with osteoporosis remains controversial. Is CBT better than BC? Research on this issue is lacking. Methods:Ten porcine spines with 3 segments were treated with EDTA decalcification. After 8 weeks, all the models met the criteria of low bone mass. Ten specimens were randomly divided into groups, group was implanted with CBT screw (CBT group) and the other group was implanted with bone cement screw (BC group). The biomechanical material testing machine was used to compare the porcine spine activities of the two groups in flexion, extension, bending, and axial rotation, and then insertional torque, pull-out force, and anti-compression force of the 2 groups were compared. Independent sample t test was used for comparison between groups. Results: Ten 3 segments of porcine spine models with low bone mass were established, and the bone mineral density of all models was lower than 0.75 g/cm(2). There is no difference between the CBT and BC groups in flexion, extension, bending, and axial rotation angle, P>0.05. However, there were significant differences between the 2 groups and the control group, with P<0.01. The 2 groups significantly differed between the insertional torque (P=0.03) and the screw pull-out force (P=0.021). The anti-compression forces between the 2 groups have no significant difference between the two groups (P=0.946). Conclusions: The insertional torque and pull-out force of the CBT were higher than those of the BC in the isolated low bone porcine spine model. The range of motion and anti-compression ability of the model was similar between the 2 fixation methods.
引用
收藏
页码:E145 / E152
页数:8
相关论文
共 50 条
  • [41] Minimally invasive lumbar pedicle screw fixation using cortical bone trajectory - Screw accuracy, complications, and learning curve in 100 screw placements
    Dayani, Fara
    Chen, Yi-Ren
    Johnson, Eli
    Deb, Sayantan
    Wu, Yunfen
    Lan Pham
    Singh, Harminder
    JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 61 : 106 - 111
  • [42] Cortical Bone Trajectory Pedicle Screw Fixation in Surgical Treatment of Monosegmental Pyogenic Lumbar Spondylodiskitis
    Shin, Jae-Hyuk
    Kim, Sang-Il
    Jung, Jiyoung
    Rhyu, Kee-Won
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2023, 84 (01) : 37 - 43
  • [43] Minimally Invasive Lumbar Pedicle Screw Fixation Using Cortical Bone Trajectory: Functional Outcomes
    Chen, Yiren
    Deb, Sayantan
    Jabarkheel, Rashad
    Pham, Lan
    Patel, Mahesh
    Singh, Harminder
    CUREUS, 2018, 10 (10):
  • [44] Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Kato, Takashi
    Imabayashi, Hideaki
    Asazuma, Takashi
    Nemoto, Koichi
    JOURNAL OF NEUROSURGERY-SPINE, 2014, 21 (02) : 203 - 209
  • [45] A Novel Calcium Phosphate-Based Nanocomposite for Augmentation of Cortical Bone Trajectory Screw Fixation
    Wang, Yuetian
    Liu, Chun
    Liu, Huiling
    Fu, Haoyong
    Li, Chunde
    Yang, Lei
    Sun, Haolin
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2022, 17 : 3059 - 3071
  • [46] Biomechanical Evaluation of Cross Trajectory Technique for Pedicle Screw Insertion: Combined Use of Traditional Trajectory and Cortical Bone Trajectory
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Imabayashi, Hideaki
    Hosogane, Naobumi
    Asazuma, Takashi
    Nemoto, Koichi
    ORTHOPAEDIC SURGERY, 2015, 7 (04) : 317 - 323
  • [47] Biomechanical study of space frame structure based on bone cement screw
    Xiu, Jintao
    Bu, Tao
    Yan, Yabo
    Wu, Zixiang
    Yin, Zhanhai
    Lei, Wei
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 19 (06) : 3650 - 3656
  • [48] A Biomechanical Analysis of Interference Screw Versus Bone Tunnel Fixation of Flexor Hallucis Longus Tendon Transfers to the Calcaneus
    Liu, George T.
    Balldin, B. Christian
    Zide, Jacob R.
    Chen, Christopher T.
    JOURNAL OF FOOT & ANKLE SURGERY, 2017, 56 (04): : 813 - 816
  • [49] BIOMECHANICAL CADAVERIC ANALYSIS OF BIOTENODESIS SCREW VERSUS BONE TUNNEL FIXATION METHODS IN FLEXOR HALLUCIS LONGUS TRANSFERS
    Balidin, B. Christian
    Zide, Jacob R.
    Liu, George T.
    Chen, Christopher T.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [50] Enhancing Pedicle Screw Fixation in the Aging Spine With a Novel Bioactive Bone Cement An In Vitro Biomechanical Study
    Zhu, Qingan
    Kingwell, Stephen
    Li, Zhaoyang
    Pan, Haobo
    Lu, William W.
    Oxland, Thomas R.
    SPINE, 2012, 37 (17) : E1030 - E1037