Biomechanical Analysis of Cortical Bone Trajectory Screw Versus Bone Cement Screw for Fixation in Porcine Spinal Low Bone Mass Model

被引:2
|
作者
Li, Yifan [1 ]
Wang, Silian [2 ]
Zhu, Zhenbiao [4 ]
Chen, Liwei [2 ]
Shi, Zhangpeng [3 ]
Ye, Xiaojian [1 ]
Xu, Wei [1 ]
Li, Zhikun [1 ,5 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Orthoped, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Tongren Hosp, Sch Med, Dept Imaging, Shanghai, Peoples R China
[3] Anhui Med Univ, Shanghai Clin Coll, Shanghai, Peoples R China
[4] Cent South Univ, Dept Orthopaed, Xiangya Sch Med, Affiliated Haikou Hosp, Haikou, Hainan, Peoples R China
[5] Shanghai Tongren Hosp, Shanghai, Peoples R China
来源
CLINICAL SPINE SURGERY | 2023年 / 36卷 / 04期
关键词
cortical bone trajectory screw; bone cement screw; biomechanical analysis; porcine spinal model; PEDICLE; AUGMENTATION; PLACEMENT; ADJACENT;
D O I
10.1097/BSD.0000000000001395
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: A prospective study of in vitro animal. Objection: To compare the biomechanics of cortical bone trajectory screw (CBT) and bone cement screw (BC) in an isolated porcine spinal low bone mass model. Summary of Background Data: The choice of spinal fixation in patients with osteoporosis remains controversial. Is CBT better than BC? Research on this issue is lacking. Methods:Ten porcine spines with 3 segments were treated with EDTA decalcification. After 8 weeks, all the models met the criteria of low bone mass. Ten specimens were randomly divided into groups, group was implanted with CBT screw (CBT group) and the other group was implanted with bone cement screw (BC group). The biomechanical material testing machine was used to compare the porcine spine activities of the two groups in flexion, extension, bending, and axial rotation, and then insertional torque, pull-out force, and anti-compression force of the 2 groups were compared. Independent sample t test was used for comparison between groups. Results: Ten 3 segments of porcine spine models with low bone mass were established, and the bone mineral density of all models was lower than 0.75 g/cm(2). There is no difference between the CBT and BC groups in flexion, extension, bending, and axial rotation angle, P>0.05. However, there were significant differences between the 2 groups and the control group, with P<0.01. The 2 groups significantly differed between the insertional torque (P=0.03) and the screw pull-out force (P=0.021). The anti-compression forces between the 2 groups have no significant difference between the two groups (P=0.946). Conclusions: The insertional torque and pull-out force of the CBT were higher than those of the BC in the isolated low bone porcine spine model. The range of motion and anti-compression ability of the model was similar between the 2 fixation methods.
引用
收藏
页码:E145 / E152
页数:8
相关论文
共 50 条
  • [21] Fatigue Performance of Cortical Bone Trajectory Screw Compared With Standard Trajectory Pedicle Screw
    Akpolat, Yusuf Tahiri
    Inceoglu, Serkan
    Kinne, Nolan
    Hunt, Devon
    Cheng, Wayne K.
    SPINE, 2016, 41 (06) : E335 - E341
  • [22] Biomechanical and finite element analyses of bone cement-Injectable cannulated pedicle screw fixation in osteoporotic bone
    Liu, Yaoyao
    Xu, Jianzhong
    Sun, Dong
    Luo, Fei
    Zhang, Zehua
    Dai, Fei
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2016, 104 (05) : 960 - 967
  • [23] Biomechanical analysis of an interference screw and a novel twist lock screw design for bone graft fixation
    Asnis, S.
    Mullen, J.
    Asnis, P. D.
    Sgaglione, N.
    LaPorta, T.
    Grande, D. A.
    Chahine, N. O.
    CLINICAL BIOMECHANICS, 2017, 50 : 99 - 104
  • [24] Biomechanical Comparison of a Headless Compression Screw Fastener and AO Cortical Bone Screw for Fixation of a Simulated Equine Third Carpal Bone Slab Fracture
    Salinger, Allison
    Mochal-King, Cathleen
    Clinton, Kailey
    Priddy, Lauren B.
    Elder, Steve
    Fontenot, Robin
    Eddy, Alison
    Wills, Robert
    Jaffe, Michael
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2022, 118
  • [25] Optimal screw diameter for interference fixation in a bone tunnel: a porcine model
    M. W. J. Morris
    J. L. Williams
    A. J. Thake
    Y. Lang
    J. N. Brown
    Knee Surgery, Sports Traumatology, Arthroscopy, 2004, 12 : 486 - 489
  • [26] Midline Lumbar Fusion with Cortical Bone Trajectory Screw
    Mizuno, Masaki
    Kuraishi, Keita
    Umeda, Yasuyuki
    Sano, Takanori
    Tsuji, Masanori
    Suzuki, Hidenori
    NEUROLOGIA MEDICO-CHIRURGICA, 2014, 54 (09) : 716 - 721
  • [27] Optimal screw diameter for interference fixation in a bone tunnel: a porcine model
    Morris, MWJ
    Williams, JL
    Thake, AJ
    Lang, Y
    Brown, JN
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (05) : 486 - 489
  • [28] Biomechanical investigation of the hybrid modified cortical bone screw-pedicle screw fixation technique: Finite-element analysis
    Kahaer, Alafate
    Maimaiti, Xieraili
    Maitirouzi, Julaiti
    Wang, Shuiquan
    Shi, Wenjie
    Abuduwaili, Nueraihemaiti
    Zhou, Zhihao
    Liu, Dongshan
    Maimaiti, Abulikemu
    Rexiti, Paerhati
    FRONTIERS IN SURGERY, 2022, 9
  • [29] Fluoroscopic versus CT-guided cortical bone trajectory pedicle screw fixation: Comparing trajectory related complications
    Kumar, Kevin K.
    Parikh, Bhavya
    Jabarkheel, Rashad
    Dirlikov, Benjamin
    Singh, Harminder
    JOURNAL OF CLINICAL NEUROSCIENCE, 2021, 89 : 354 - 359
  • [30] Cortical bone trajectory and traditional trajectory-a radiological evaluation of screw-bone contact
    Kojima, Kota
    Asamoto, Shunji
    Kobayashi, Yoshiomi
    Ishikawa, Masayuki
    Fukui, Yasuyuki
    ACTA NEUROCHIRURGICA, 2015, 157 (07) : 1173 - 1178