Biomechanical Analysis of Cortical Bone Trajectory Screw Versus Bone Cement Screw for Fixation in Porcine Spinal Low Bone Mass Model

被引:2
|
作者
Li, Yifan [1 ]
Wang, Silian [2 ]
Zhu, Zhenbiao [4 ]
Chen, Liwei [2 ]
Shi, Zhangpeng [3 ]
Ye, Xiaojian [1 ]
Xu, Wei [1 ]
Li, Zhikun [1 ,5 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Orthoped, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Tongren Hosp, Sch Med, Dept Imaging, Shanghai, Peoples R China
[3] Anhui Med Univ, Shanghai Clin Coll, Shanghai, Peoples R China
[4] Cent South Univ, Dept Orthopaed, Xiangya Sch Med, Affiliated Haikou Hosp, Haikou, Hainan, Peoples R China
[5] Shanghai Tongren Hosp, Shanghai, Peoples R China
来源
CLINICAL SPINE SURGERY | 2023年 / 36卷 / 04期
关键词
cortical bone trajectory screw; bone cement screw; biomechanical analysis; porcine spinal model; PEDICLE; AUGMENTATION; PLACEMENT; ADJACENT;
D O I
10.1097/BSD.0000000000001395
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: A prospective study of in vitro animal. Objection: To compare the biomechanics of cortical bone trajectory screw (CBT) and bone cement screw (BC) in an isolated porcine spinal low bone mass model. Summary of Background Data: The choice of spinal fixation in patients with osteoporosis remains controversial. Is CBT better than BC? Research on this issue is lacking. Methods:Ten porcine spines with 3 segments were treated with EDTA decalcification. After 8 weeks, all the models met the criteria of low bone mass. Ten specimens were randomly divided into groups, group was implanted with CBT screw (CBT group) and the other group was implanted with bone cement screw (BC group). The biomechanical material testing machine was used to compare the porcine spine activities of the two groups in flexion, extension, bending, and axial rotation, and then insertional torque, pull-out force, and anti-compression force of the 2 groups were compared. Independent sample t test was used for comparison between groups. Results: Ten 3 segments of porcine spine models with low bone mass were established, and the bone mineral density of all models was lower than 0.75 g/cm(2). There is no difference between the CBT and BC groups in flexion, extension, bending, and axial rotation angle, P>0.05. However, there were significant differences between the 2 groups and the control group, with P<0.01. The 2 groups significantly differed between the insertional torque (P=0.03) and the screw pull-out force (P=0.021). The anti-compression forces between the 2 groups have no significant difference between the two groups (P=0.946). Conclusions: The insertional torque and pull-out force of the CBT were higher than those of the BC in the isolated low bone porcine spine model. The range of motion and anti-compression ability of the model was similar between the 2 fixation methods.
引用
收藏
页码:E145 / E152
页数:8
相关论文
共 50 条
  • [31] An approximate model for cancellous bone screw fixation
    Brown, C. J.
    Sinclair, R. A.
    Day, A.
    Hess, B.
    Procter, P.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 (04) : 443 - 450
  • [32] Depth of vertebral screw insertion using a cortical bone trajectory technique in lumbar spinal fusion: radiological significance of a long cortical bone trajectory
    Matsukawa, Keitaro
    Yanai, Yoshihide
    Fujiyoshi, Kanehiro
    Kato, Takashi
    Yato, Yoshiyuki
    JOURNAL OF NEUROSURGERY-SPINE, 2021, 35 (05) : 601 - 606
  • [33] Comparative biomechanical analysis of an improved novel pedicle screw with sheath and bone cement
    Takigawa, Tomoyuki
    Tanaka, Masato
    Konishi, Hitoshi
    Ikuma, Hisanori
    Misawa, Haruo
    Sugimoto, Yoshihisa
    Nakanishi, Kazuo
    Kuramoto, Koichi
    Nishida, Keiichiro
    Ozaki, Toshifumi
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (06): : 462 - 467
  • [34] Bone Cement-Augmented Percutaneous Screw Fixation for Malignant Spinal Metastases : Is It Feasible?
    Kim, Pius
    Kim, Seok Won
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2017, 60 (02) : 189 - 194
  • [35] Combination of sacral-alar-iliac screw and cortical bone trajectory screw techniques for lumbosacral fixation: technical note
    Matsukawa, Keitaro
    Kato, Takashi
    Mobbs, Ralph
    Yato, Yoshiyuki
    Asazuma, Takashi
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 33 (02) : 186 - 191
  • [36] Coracoid bone block fixation with cortical buttons: An alternative to screw fixation?
    Gendre, P.
    Thelu, C. -E.
    d'Ollonne, T.
    Trojani, C.
    Gonzalez, J. -F.
    Boileau, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (08) : 983 - 987
  • [37] Regional Hounsfield unit measurement of screw trajectory for predicting pedicle screw fixation using cortical bone trajectory: a retrospective cohort study
    Keitaro Matsukawa
    Yuichiro Abe
    Yoshihide Yanai
    Yoshiyuki Yato
    Acta Neurochirurgica, 2018, 160 : 405 - 411
  • [38] Regional Hounsfield unit measurement of screw trajectory for predicting pedicle screw fixation using cortical bone trajectory: a retrospective cohort study
    Matsukawa, Keitaro
    Abe, Yuichiro
    Yanai, Yoshihide
    Yato, Yoshiyuki
    ACTA NEUROCHIRURGICA, 2018, 160 (02) : 405 - 411
  • [39] The Effect of Screw Length and Bone Cement Augmentation on the Fixation Strength of Iliac Screws A Biomechanical Study
    Zheng, Zhao-Min
    Zhang, Kui-Bo
    Zhang, Jia-Fang
    Yu, Bin-Sheng
    Liu, Hui
    Zhuang, Xin-Ming
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (08): : 545 - 550
  • [40] Cortical bone screw fixation in lonically modified apatite cements
    Barralet, JE
    Duncan, CO
    Dover, MS
    Bassett, DC
    Nishikawa, H
    Monaghan, A
    Gbureck, U
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 73B (02) : 238 - 243