Comparison of Easydo Activator, ultrasonic and needle irrigation techniques on sealer penetration and smear layer removal in vitro

被引:0
|
作者
Zhang, Shao-Hui [1 ,2 ]
Gao, Zheng-Rong [1 ]
Zhou, Ying-Hui [3 ,4 ]
Tan, Li [1 ]
Feng, Yao [1 ]
Ye, Qin [1 ]
Zhao, Jie [1 ]
Zhao, Ya-Qiong [1 ]
Hu, Jing [1 ]
Chen, Yun [1 ]
Liu, Qiong [1 ]
Aimee, Dusenge Marie [1 ]
Guo, Yue [1 ]
Feng, Yun-Zhi [1 ]
机构
[1] Cent South Univ, Xiangya Hosp 2, Hunan Prov Clin Res Ctr Oral Dis, Hunan Prov Engn Res Ctr Digital Oral & Maxillofaci, Changsha 410011, Hunan, Peoples R China
[2] Hubei Univ Arts & Sci, Xiangyang Cent Hosp, Dept Stomatol, Affiliated Hosp, Xiangyang 441000, Hubei, Peoples R China
[3] Cent South Univ, Xiangya Hosp 2, Dept Ultrasound Diag, Changsha 410011, Hunan, Peoples R China
[4] Cent South Univ, Natl Clin Res Ctr Metab Dis, Dept Metab & Endocrinol, Hunan Prov Key Lab Metab Bone Dis,Xiangya Hosp 2, Changsha 410011, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Irrigation; Root canal therapy; Sealer penetration; Smear layer removal; Easydo activator; Scanning electron microscopy; Confocal laser scanning microscopy; DENTINAL TUBULE PENETRATION; APICAL; 3RD; ROOT; CANALS; VIBRINGE; EFFICACY; SYRINGE; SYSTEM; TEETH; MTA;
D O I
10.1186/s12903-023-03833-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The effects of Easydo Activator (EA), a new sonic irrigation system, on sealer penetration at the root apex were compared to needle irrigation (NI) and passive ultrasonic irrigation (PUI) in this study. Forty-two single-rooted teeth were prepared and randomly divided into three groups (n = 14): group 1: NI; group 2: PUI; and group 3: EA. A solution of 3% sodium hypochlorite (NaOCl) was used for irrigation. Nine teeth in each group were filled with AH Plus sealer mixed with CY5 fluorescent dye and a single gutta-percha cone. The sealer penetration area, maximum penetration depth and percentage of sealer penetration at 5 mm and 1 mm from the apex were analyzed by confocal laser scanning microscopy (CLSM). The remaining 5 teeth in each group were subjected to test smear layer scores by scanning electron microscopy (SEM). The CLSM evaluation showed that increases in the area, depth and percentage of sealer penetration were detected at 1 and 5 mm from the root apex in the PUI group compared with the NI group, and greater increases were observed in the EA group (P < 0.05). The SEM experiment showed that the lowest scores for the smear layer and debris removal were achieved by the EA group when compared with the PUI and NI groups (P < 0.05). In conclusion, EA was superior to PUI and NI regarding sealer penetration at the root apex during endodontic treatment, and it could provide a new technical idea for clinical root canal therapy.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Comparison of Easydo Activator, ultrasonic and needle irrigation techniques on sealer penetration and smear layer removal in vitro
    Shao-Hui Zhang
    Zheng-Rong Gao
    Ying-Hui Zhou
    Li Tan
    Yao Feng
    Qin Ye
    Jie Zhao
    Ya-Qiong Zhao
    Jing Hu
    Yun Chen
    Qiong Liu
    Dusenge Marie Aimee
    Yue Guo
    Yun-Zhi Feng
    BMC Oral Health, 24
  • [2] Comparison of EASYDO ACTIVATOR, passive ultrasonic, and needle irrigation techniques on the treatment of apical periodontitis: a study in rats
    Qin Ye
    Yao Feng
    Ya-Qiong Zhao
    Li Tan
    Jing Hu
    Shao-Hui Zhang
    Jie Zhao
    Ying-Hui Zhou
    Yue Guo
    Yun-Zhi Feng
    Clinical Oral Investigations, 2022, 26 : 7157 - 7165
  • [3] Comparison of EASYDO ACTIVATOR, passive ultrasonic, and needle irrigation techniques on the treatment of apical periodontitis: a study in rats
    Ye, Qin
    Feng, Yao
    Zhao, Ya-Qiong
    Tan, Li
    Hu, Jing
    Zhang, Shao-Hui
    Zhao, Jie
    Zhou, Ying-Hui
    Guo, Yue
    Feng, Yun-Zhi
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (12) : 7157 - 7165
  • [4] Comparison of Different Irrigation Activation Techniques on Smear Layer Removal: An in vitro Study
    Ekim, Sefika Nur Akyuz
    Erdemir, Ali
    MICROSCOPY RESEARCH AND TECHNIQUE, 2015, 78 (03) : 230 - 239
  • [5] Comparison of Sealer Penetration by Using Different Irrigation Techniques - An In-vitro Study
    Ismail, Prabu Mahin Syed
    Ahamed, Siddiq
    Sabiha, P. B.
    Sekhar, M. Chandra
    Moosani, Gopikrishna
    Reddy, S. Nagalakshmi
    Reddy, N. Upendranatha
    Sumanthi, C. H.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (12) : ZC50 - ZC53
  • [6] Efficacy of Photoinduced Photoacoustic Streaming and Diode Laser Irrigation Techniques on Smear Layer Removal, Sealer Penetration and Push-out Bond Strength
    Abdelgawad, Latifa Mohamed
    ElShafei, Nancy Attia Ahmed
    Eissa, Somaia Abdlatif
    Ibrahim, Dalia Yahia
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2022, 13
  • [7] The effect of 17% EDTA and QMiX ultrasonic activation on smear layer removal and sealer penetration: ex vivo study
    Matos, Felipe de Souza
    da Silva, Fabricio Rutz
    Paranhos, Luiz Renato
    Gomes Moura, Camilla Christian
    Bresciani, Eduardo
    Valera, Marcia Carneiro
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [8] SMEAR LAYER REMOVAL - COMPARISON OF ROTARY VS ULTRASONIC RETROPREPARATION TECHNIQUES
    DOUGHERTY, RM
    HANSEN, SR
    CUNNINGHAM, CJ
    MURCHISON, DF
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 160 - 160
  • [9] The effect of 17% EDTA and QMiX ultrasonic activation on smear layer removal and sealer penetration: ex vivo study
    Felipe de Souza Matos
    Fabrício Rutz da Silva
    Luiz Renato Paranhos
    Camilla Christian Gomes Moura
    Eduardo Bresciani
    Marcia Carneiro Valera
    Scientific Reports, 10
  • [10] Comparison of Endovac irrigation system with conventional irrigation for removal of intracanal smear layer: an in vitro study
    Abarajithan, Mohan
    Dham, Sonal
    Velmurugan, Natanasabapathy
    Valerian-Albuquerque, Denzil
    Ballal, Suma
    Senthilkumar, Hemamalathi
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (03): : 407 - 411