An analysis of reconstruction noise from undersampled 4D flow MRI

被引:1
|
作者
Partin, Lauren [1 ]
Schiavazzi, Daniele E. [1 ]
Long, Carlos A. Sing [2 ,3 ]
机构
[1] Univ Notre Dame, Dept Appl & Computat Math & Stat, 102G Crowley Hall, Notre Dame, IN 46556 USA
[2] Pontificia Univ Catolica Chile, Inst Math & Computat Engn, Av Vicuna Mackenna 4860, Santiago 7820436, Chile
[3] Pontificia Univ Catolica Chile, Inst Biol & Med Engn, Av Vicuna Mackenna 4860, Santiago 7820436, Chile
关键词
4D flow MRI; Compressed Sensing; MRI noise characterization; Uncertainty propagation; ROBUST UNCERTAINTY PRINCIPLES; SPARSE LINEAR-EQUATIONS; SIGNAL RECOVERY; LSQR;
D O I
10.1016/j.bspc.2023.104800
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Novel Magnetic Resonance (MR) imaging modalities can quantify hemodynamics but require long acquisition times, precluding its widespread use for early diagnosis of cardiovascular disease. To reduce acquisition times, flow reconstruction from undersampled data is routinely performed. Reconstructed anatomical and hemodynamic images may present visual artifacts. While some artifacts are reconstruction errors, and a consequence of undersampling, others are due to measurement noise or the random choice of samples. A reconstructed image becomes thus a random variable: its bias leads to systematic reconstruction errors, whereas its fluctuations may induce spatial correlations that may be misconstrued for visual information or that may carry to quantities of interest computed from the image. Although the former has been studied in the literature, the latter has not received as much attention. In this study, we investigate the theoretical properties of the random perturbations arising from the reconstruction process. To our knowledge, this is the first study on this topic. We perform numerical experiments on simulated flow, on aortic phantom flow, and on aortic flow. These show that the correlation length remains limited to two to three pixels when a Gaussian undersampling pattern is combined with l(1)-norm minimization methods. The correlation length may increase significantly for other undersampling patterns, higher undersampling factors (i.e., higher than 8x compression), and other reconstruction methods. Our findings suggest that the reconstruction method has a large impact on the correlation. As reconstruction methods are routinely used in practice, the impact of these random perturbations in practical applications merits further study.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] The value of 4D flow MRI in cardiac assessment
    Nicholls, Mark
    EUROPEAN HEART JOURNAL, 2022, 43 (10) : 930 - 932
  • [22] 4D flow MRI velocity uncertainty quantification
    Rothenberger, Sean M.
    Zhang, Jiacheng
    Markl, Michael
    Craig, Bruce A.
    Vlachos, Pavlos P.
    Rayz, Vitaliy L.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (01) : 397 - 410
  • [23] Why 4D Flow MRI? Real Advantages
    Takehara, Yasuo
    Sekine, Tetsuro
    Obata, Takayuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 253 - 256
  • [24] 4D Flow MRI Applications for Aortic Disease
    Burris, Nicholas S.
    Hope, Michael D.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (01) : 15 - +
  • [25] Abdominal applications of quantitative 4D flow MRI
    Oechtering, Thekla H.
    Roberts, Grant S.
    Panagiotopoulos, Nikolaos
    Wieben, Oliver
    Roldan-Alzate, Alejandro
    Reeder, Scott B.
    ABDOMINAL RADIOLOGY, 2022, 47 (09) : 3229 - 3250
  • [26] On the limitations of echo planar 4D flow MRI
    Dillinger, Hannes
    Walheim, Jonas
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (04) : 1806 - 1816
  • [27] Abdominal applications of quantitative 4D flow MRI
    Thekla H. Oechtering
    Grant S. Roberts
    Nikolaos Panagiotopoulos
    Oliver Wieben
    Alejandro Roldán-Alzate
    Scott B. Reeder
    Abdominal Radiology, 2022, 47 : 3229 - 3250
  • [28] A practical introduction to the hemodynamic analysis of the cardiovascular system with 4D Flow MRI
    Pineda Zapata, J. A.
    Delgado de Bedouta, J. A.
    Rascovsky Ramireza, S.
    Bustamante, C.
    Mesa, S.
    Calvo Betancur, V. D.
    RADIOLOGIA, 2014, 56 (06): : 485 - 495
  • [29] 4D flow MRI for the analysis of celiac trunk and mesenteric artery stenoses
    Siedek, Florian
    Giese, Daniel
    Weiss, Kilian
    Ekdawi, Sandra
    Brinkmann, Sebastian
    Schroeder, Wolfgang
    Bruns, Christiane
    Chang, De-Hua
    Persigehl, Thorsten
    Maintz, David
    Haneder, Stefan
    MAGNETIC RESONANCE IMAGING, 2018, 53 : 52 - 62
  • [30] Emerging Applications of Abdominal 4D Flow MRI
    Roldan-Alzate, Alejandro
    Francois, Christopher J.
    Wieben, Oliver
    Reeder, Scott B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 58 - 66