An analysis of reconstruction noise from undersampled 4D flow MRI

被引:1
|
作者
Partin, Lauren [1 ]
Schiavazzi, Daniele E. [1 ]
Long, Carlos A. Sing [2 ,3 ]
机构
[1] Univ Notre Dame, Dept Appl & Computat Math & Stat, 102G Crowley Hall, Notre Dame, IN 46556 USA
[2] Pontificia Univ Catolica Chile, Inst Math & Computat Engn, Av Vicuna Mackenna 4860, Santiago 7820436, Chile
[3] Pontificia Univ Catolica Chile, Inst Biol & Med Engn, Av Vicuna Mackenna 4860, Santiago 7820436, Chile
关键词
4D flow MRI; Compressed Sensing; MRI noise characterization; Uncertainty propagation; ROBUST UNCERTAINTY PRINCIPLES; SPARSE LINEAR-EQUATIONS; SIGNAL RECOVERY; LSQR;
D O I
10.1016/j.bspc.2023.104800
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Novel Magnetic Resonance (MR) imaging modalities can quantify hemodynamics but require long acquisition times, precluding its widespread use for early diagnosis of cardiovascular disease. To reduce acquisition times, flow reconstruction from undersampled data is routinely performed. Reconstructed anatomical and hemodynamic images may present visual artifacts. While some artifacts are reconstruction errors, and a consequence of undersampling, others are due to measurement noise or the random choice of samples. A reconstructed image becomes thus a random variable: its bias leads to systematic reconstruction errors, whereas its fluctuations may induce spatial correlations that may be misconstrued for visual information or that may carry to quantities of interest computed from the image. Although the former has been studied in the literature, the latter has not received as much attention. In this study, we investigate the theoretical properties of the random perturbations arising from the reconstruction process. To our knowledge, this is the first study on this topic. We perform numerical experiments on simulated flow, on aortic phantom flow, and on aortic flow. These show that the correlation length remains limited to two to three pixels when a Gaussian undersampling pattern is combined with l(1)-norm minimization methods. The correlation length may increase significantly for other undersampling patterns, higher undersampling factors (i.e., higher than 8x compression), and other reconstruction methods. Our findings suggest that the reconstruction method has a large impact on the correlation. As reconstruction methods are routinely used in practice, the impact of these random perturbations in practical applications merits further study.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] 4D Flow with MRI
    Soulat, Gilles
    McCarthy, Patrick
    Markl, Michael
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 22, 2020, 22 : 103 - 126
  • [2] 4D flow MRI
    Markl, Michael
    Frydrychowicz, Alex
    Kozerke, Sebastian
    Hope, Mike
    Wieben, Oliver
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (05) : 1015 - 1036
  • [3] Deep variational network for rapid 4D flow MRI reconstruction
    Valery Vishnevskiy
    Jonas Walheim
    Sebastian Kozerke
    Nature Machine Intelligence, 2020, 2 : 228 - 235
  • [4] Deep variational network for rapid 4D flow MRI reconstruction
    Vishnevskiy, Valery
    Walheim, Jonas
    Kozerke, Sebastian
    NATURE MACHINE INTELLIGENCE, 2020, 2 (04) : 228 - +
  • [5] Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI
    Lantz, Jonas
    Gupta, Vikas
    Henriksson, Lilian
    Karlsson, Matts
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    RADIOLOGY, 2018, 289 (01) : 51 - 58
  • [6] The Empirical Effect of Gaussian Noise in Undersampled MRI Reconstruction
    Virtue, Patrick
    Lustig, Michael
    TOMOGRAPHY, 2017, 3 (04) : 211 - 221
  • [7] 4D flow imaging with MRI
    Stankovic, Zoran
    Allen, Bradley D.
    Garcia, Julio
    Jarvis, Kelly B.
    Markl, Michael
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (02) : 173 - 192
  • [8] 4D Flow Meets CT: Can It Compete with 4D Flow MRI?
    Schoepf, U. Joseph
    Varga-Szemes, Akos
    RADIOLOGY, 2018, 289 (01) : 59 - 60
  • [9] 4D MAP MRI IMAGE RECONSTRUCTION
    Hinkle, Jacob
    Adluru, Ganesh
    Kholmovski, Eugene
    DiBella, Edward
    Joshi, Sarang
    VISAPP 2010: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON COMPUTER VISION THEORY AND APPLICATIONS, VOL 1, 2010, : 251 - 257
  • [10] Analysis of accelerated 4D flow MRI in the murine aorta by radial acquisition and compressed sensing reconstruction
    Braig, Moritz
    Menza, Marius
    Leupold, Jochen
    LeVan, Pierre
    Feng, Li
    Ko, Cheng-Wen
    von zur Muehlen, Constantin
    Krafft, Axel J.
    Hennig, Juergen
    von Elverfeldt, Dominik
    NMR IN BIOMEDICINE, 2020, 33 (11)