Potential of Unenhanced Ultra-Low-Dose Abdominal Photon-Counting CT with Tin Filtration: A Cadaveric Study

被引:3
|
作者
Huflage, Henner [1 ]
Grunz, Jan-Peter [1 ]
Patzer, Theresa Sophie [1 ]
Pannenbecker, Pauline [1 ]
Feldle, Philipp [1 ]
Sauer, Stephanie Tina [1 ]
Petritsch, Bernhard [1 ]
Erguen, Sueleyman [2 ]
Bley, Thorsten Alexander [1 ]
Kunz, Andreas Steven [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Inst Anat & Cell Biol, Koellikerstrasse 6, D-97070 Wurzburg, Germany
关键词
spectral shaping; tin prefiltration; abdominal imaging; ultra-low-dose CT; urinary calculi; photon-counting; IMAGE QUALITY; GUIDELINE; CALCULI; RISKS; STONE;
D O I
10.3390/diagnostics13040603
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study investigated the feasibility and image quality of ultra-low-dose unenhanced abdominal CT using photon-counting detector technology and tin prefiltration. Materials and Methods: Employing a first-generation photon-counting CT scanner, eight cadaveric specimens were examined both with tin prefiltration (Sn 100 kVp) and polychromatic (120 kVp) scan protocols matched for radiation dose at three different levels: standard-dose (3 mGy), low-dose (1 mGy) and ultra-low-dose (0.5 mGy). Image quality was evaluated quantitatively by means of contrast-to-noise-ratios (CNR) with regions of interest placed in the renal cortex and subcutaneous fat. Additionally, three independent radiologists performed subjective evaluation of image quality. The intraclass correlation coefficient was calculated as a measure of interrater reliability. Results: Irrespective of scan mode, CNR in the renal cortex decreased with lower radiation dose. Despite similar mean energy of the applied x-ray spectrum, CNR was superior for Sn 100 kVp over 120 kVp at standard-dose (17.75 +/- 3.51 vs. 14.13 +/- 4.02), low-dose (13.99 +/- 2.6 vs. 10.68 +/- 2.17) and ultra-low-dose levels (8.88 +/- 2.01 vs. 11.06 +/- 1.74) (all p <= 0.05). Subjective image quality was highest for both standard-dose protocols (score 5; interquartile range 5-5). While no difference was ascertained between Sn 100 kVp and 120 kVp examinations at standard and low-dose levels, the subjective image quality of tin-filtered scans was superior to 120 kVp with ultra-low radiation dose (p < 0.05). An intraclass correlation coefficient of 0.844 (95% confidence interval 0.763-0.906; p < 0.001) indicated good interrater reliability. Conclusions: Photon-counting detector CT permits excellent image quality in unenhanced abdominal CT with very low radiation dose. Employment of tin prefiltration at 100 kVp instead of polychromatic imaging at 120 kVp increases the image quality even further in the ultra-low-dose range of 0.5 mGy.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter
    Rajendran, Kishore
    Voss, Benjamin A.
    Zhou, Wei
    Tao, Shengzhen
    DeLone, David R.
    Lane, John, I
    Weaver, Jayse M.
    Carlson, Matthew L.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    INVESTIGATIVE RADIOLOGY, 2020, 55 (02) : 91 - 100
  • [32] Ultra-High-Resolution Photon-Counting Detector CT Arthrography of the Ankle: A Feasibility Study
    Luetkens, Karsten Sebastian
    Grunz, Jan-Peter
    Kunz, Andreas Steven
    Huflage, Henner
    Weissenberger, Manuel
    Hartung, Viktor
    Patzer, Theresa Sophie
    Gruschwitz, Philipp
    Erguen, Sueleyman
    Bley, Thorsten Alexander
    Feldle, Philipp
    DIAGNOSTICS, 2023, 13 (13)
  • [33] Performance of calcium quantifications on low-dose photon-counting detector CT with high-pitch: A phantom study
    Zhou, Shanshui
    Liu, Peng
    Dong, Haipeng
    Li, Jiqiang
    Xu, Zhihan
    Schmidt, Bernhard
    Lin, Shushen
    Yang, Wenjie
    Yan, Fuhua
    Qin, Le
    HELIYON, 2024, 10 (12)
  • [34] Ultra-low-dose unenhanced chest CT: Prospective comparison of high kV/low mA versus low kV/high mA protocols
    Ludes, C.
    Labani, A.
    Severac, F.
    Jeung, M. Y.
    Leyendecker, P.
    Roy, C.
    Ohana, M.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2019, 100 (02) : 85 - 93
  • [35] Dose-efficient assessment of trabecular microstructure using ultra-high-resolution photon-counting CT
    Pena, Jaime A.
    Klein, Laura
    Maier, Joscha
    Damm, Timo
    Schlemmer, Heinz-Peter
    Engelke, Klaus
    Gluer, Claus-Christian
    Kachelriess, Marc
    Sawall, Stefan
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2022, 32 (04): : 403 - 416
  • [36] Photon-counting CT for diagnosis of acute pulmonary embolism: potential for contrast medium and radiation dose reduction
    Pannenbecker, Pauline
    Huflage, Henner
    Grunz, Jan-Peter
    Gruschwitz, Philipp
    Patzer, Theresa S.
    Weng, Andreas M.
    Heidenreich, Julius F.
    Bley, Thorsten A.
    Petritsch, Bernhard
    EUROPEAN RADIOLOGY, 2023, 33 (11) : 7830 - 7839
  • [37] Photon-counting CT for diagnosis of acute pulmonary embolism: potential for contrast medium and radiation dose reduction
    Pauline Pannenbecker
    Henner Huflage
    Jan-Peter Grunz
    Philipp Gruschwitz
    Theresa S. Patzer
    Andreas M. Weng
    Julius F. Heidenreich
    Thorsten A. Bley
    Bernhard Petritsch
    European Radiology, 2023, 33 : 7830 - 7839
  • [38] Ultra-low-dose CT for attenuation correction: dose savings and effect on PET quantification for protocols with and without tin filter
    Bebbington N.A.
    Christensen K.B.
    Østergård L.L.
    Holdgaard P.C.
    EJNMMI Physics, 10 (1)
  • [39] Ultra-low-dose CT for Long Axial Field of View PET/CT: A Phantom Study
    Mostafapour, S.
    Greuter, M.
    van Snick, P.
    van Sluis, J.
    Lammertsma, A. A.
    Tsoumpas, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S228 - S229
  • [40] Low Dose Breast CT with Photon Counting Detectors: A Phantom Study
    Le, H.
    Ducote, J.
    Klopfer, M.
    Molloi, S.
    MEDICAL PHYSICS, 2009, 36 (06) : 2467 - +