Potential of Unenhanced Ultra-Low-Dose Abdominal Photon-Counting CT with Tin Filtration: A Cadaveric Study

被引:3
|
作者
Huflage, Henner [1 ]
Grunz, Jan-Peter [1 ]
Patzer, Theresa Sophie [1 ]
Pannenbecker, Pauline [1 ]
Feldle, Philipp [1 ]
Sauer, Stephanie Tina [1 ]
Petritsch, Bernhard [1 ]
Erguen, Sueleyman [2 ]
Bley, Thorsten Alexander [1 ]
Kunz, Andreas Steven [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Inst Anat & Cell Biol, Koellikerstrasse 6, D-97070 Wurzburg, Germany
关键词
spectral shaping; tin prefiltration; abdominal imaging; ultra-low-dose CT; urinary calculi; photon-counting; IMAGE QUALITY; GUIDELINE; CALCULI; RISKS; STONE;
D O I
10.3390/diagnostics13040603
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study investigated the feasibility and image quality of ultra-low-dose unenhanced abdominal CT using photon-counting detector technology and tin prefiltration. Materials and Methods: Employing a first-generation photon-counting CT scanner, eight cadaveric specimens were examined both with tin prefiltration (Sn 100 kVp) and polychromatic (120 kVp) scan protocols matched for radiation dose at three different levels: standard-dose (3 mGy), low-dose (1 mGy) and ultra-low-dose (0.5 mGy). Image quality was evaluated quantitatively by means of contrast-to-noise-ratios (CNR) with regions of interest placed in the renal cortex and subcutaneous fat. Additionally, three independent radiologists performed subjective evaluation of image quality. The intraclass correlation coefficient was calculated as a measure of interrater reliability. Results: Irrespective of scan mode, CNR in the renal cortex decreased with lower radiation dose. Despite similar mean energy of the applied x-ray spectrum, CNR was superior for Sn 100 kVp over 120 kVp at standard-dose (17.75 +/- 3.51 vs. 14.13 +/- 4.02), low-dose (13.99 +/- 2.6 vs. 10.68 +/- 2.17) and ultra-low-dose levels (8.88 +/- 2.01 vs. 11.06 +/- 1.74) (all p <= 0.05). Subjective image quality was highest for both standard-dose protocols (score 5; interquartile range 5-5). While no difference was ascertained between Sn 100 kVp and 120 kVp examinations at standard and low-dose levels, the subjective image quality of tin-filtered scans was superior to 120 kVp with ultra-low radiation dose (p < 0.05). An intraclass correlation coefficient of 0.844 (95% confidence interval 0.763-0.906; p < 0.001) indicated good interrater reliability. Conclusions: Photon-counting detector CT permits excellent image quality in unenhanced abdominal CT with very low radiation dose. Employment of tin prefiltration at 100 kVp instead of polychromatic imaging at 120 kVp increases the image quality even further in the ultra-low-dose range of 0.5 mGy.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast
    Kalender, Willi A.
    Kolditz, Daniel
    Steiding, Christian
    Ruth, Veikko
    Lueck, Ferdinand
    Rossler, Ann-Christin
    Wenkel, Evelyn
    EUROPEAN RADIOLOGY, 2017, 27 (03) : 1081 - 1086
  • [42] Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast
    Willi A. Kalender
    Daniel Kolditz
    Christian Steiding
    Veikko Ruth
    Ferdinand Lück
    Ann-Christin Rößler
    Evelyn Wenkel
    European Radiology, 2017, 27 : 1081 - 1086
  • [43] Photon-Counting Detector CT: Potential for 75% Reduction in Contrast Medium Amount: A Phantom Study
    Higaki, Fumiyo
    Morimitsu, Yusuke
    Iguchi, Toshihiro
    Saito, Hayato
    Takaki, Haruhiko
    Nakagoshi, Ayako
    Wada, Maki
    Uka, Mayu
    Akagi, Noriaki
    Mitsuhashi, Toshiharu
    Matsui, Yusuke
    Hiraki, Takao
    ACTA MEDICA OKAYAMA, 2024, 78 (02) : 135 - 142
  • [44] Detection of pulmonary nodules with scoutless fixed-dose ultra-low-dose CT: a prospective study
    Gerald Gheysens
    Walter De Wever
    Lesley Cockmartin
    Hilde Bosmans
    Walter Coudyzer
    Sofie De Vuysere
    Mathieu Lefere
    European Radiology, 2022, 32 : 4437 - 4445
  • [45] Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results
    Petritsch, Bernhard
    Kosmala, Aleksander
    Weng, Andreas Max
    Bley, Thorsten Alexander
    PLOS ONE, 2019, 14 (05):
  • [46] Detection of pulmonary nodules with scoutless fixed-dose ultra-low-dose CT: a prospective study
    Gheysens, Gerald
    De Wever, Walter
    Cockmartin, Lesley
    Bosmans, Hilde
    Coudyzer, Walter
    De Vuysere, Sofie
    Lefere, Mathieu
    EUROPEAN RADIOLOGY, 2022, 32 (07) : 4437 - 4445
  • [47] Lesion Detectability and Radiation Dose in Spiral Breast CT With Photon-Counting Detector Technology A Phantom Study
    Shim, Sojin
    Saltybaeva, Natalia
    Berger, Nicole
    Marcon, Magda
    Alkadhi, Hatem
    Boss, Andreas
    INVESTIGATIVE RADIOLOGY, 2020, 55 (08) : 515 - 523
  • [48] Low-Dose High-Resolution Photon-Counting CT of the Lung: Radiation Dose and Image Quality in the Clinical Routine
    Woeltjen, Matthias Michael
    Niehoff, Julius Henning
    Michael, Arwed Elias
    Horstmeier, Sebastian
    Moenninghoff, Christoph
    Borggrefe, Jan
    Kroeger, Jan Robert
    DIAGNOSTICS, 2022, 12 (06)
  • [49] Potential of ultra-high-resolution photon-counting CT of bone metastases: initial experiences in breast cancer patients
    Wehrse, E.
    Sawall, S.
    Klein, L.
    Glemser, P.
    Delorme, S.
    Schlemmer, H. -P.
    Kachelriess, M.
    Uhrig, M.
    Ziener, C. H.
    Rotkopf, L. T.
    NPJ BREAST CANCER, 2021, 7 (01)
  • [50] Potential of ultra-high-resolution photon-counting CT of bone metastases: initial experiences in breast cancer patients
    E. Wehrse
    S. Sawall
    L. Klein
    P. Glemser
    S. Delorme
    H.-P. Schlemmer
    M. Kachelrieß
    M. Uhrig
    C. H. Ziener
    L. T. Rotkopf
    npj Breast Cancer, 7