A Sensitive and Reliable LC-MS/MS Method for the Determination of Ambroxol and its Application to a Pharmacokinetic Study in healthy Chinese Subjects

被引:0
|
作者
Wang, Yilin [1 ,2 ]
Zhao, Yingying [1 ,2 ]
Wu, Yingxiang [1 ,2 ]
Wang, Yan [1 ,2 ]
机构
[1] Dali Univ, Coll Pharm, Dali 671000, Peoples R China
[2] Yunnan Key Lab Screening & Res Anti Pathogen Plant, Dali 671000, Peoples R China
来源
LATIN AMERICAN JOURNAL OF PHARMACY | 2023年 / 42卷 / 03期
关键词
ambroxol; LC-MS; MS; pharmacokinetics; MASS-SPECTROMETRY METHOD; HUMAN PLASMA; HYDROCHLORIDE; AMOXICILLIN; VALIDATION; TABLET;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
. In the present study, a sensitive and reliable liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for assessment of ambroxol pharmacokinetics in human plasma sample according to FDA guidelines. Ambroxol and propranolol (internal standard, IS) were extract-ed from plasma samples using liquid-liquid extraction (LLE) with ethyl acetate. Chromatographic separation was achieved on a Luna C18column (2.0 mm x 150 mm, 5 mu m) using acetonitrile-0.1% formic acid water as the mobile phase at a flow rate of 0.6 mL/min under gradient elution procedure. Quantification was performed by using an electrospray ionization (ESI) source in the positive ion mode, and the multiple reaction monitoring (MRM) conversions of m/z 379.0 -> 263.9 for ambroxol, and m/z 260.1 -> 116.1 for IS were conducted. Correla-tion coefficients > 0.9966 were achieved for all the calibration curves with linear regression. The intra-day and inter-day precisions of ambroxol were 6.9-9.1% and 1.2-14.4%, respectively, while the corresponding accuracies were-2.4-2.8% with high extraction recovery and little matrix effect. The method developed in the current study was successfully applied to the evaluation of pharmacokinetic study of ambroxol in healthy Chinese volunteers after single oral administration of salbutamol/ambroxol fixed-dose combination granules (containing 15 mg ambroxol). Compared with the other literature available for human plasma, the current study possesses many advantages, e.g. high sensitivity (LLOQ of 0.100 ng/mL for ambroxol), low cost (small plasma volume of 100 mu L), and a short chromatographic run time (4.0 min per sample).
引用
收藏
页码:636 / 642
页数:7
相关论文
共 50 条
  • [31] LC-MS/MS Method for Determination of Hydroxychloroquine and Metabolites: Application in a Pharmacokinetic Study
    Cui, Lili
    Wang, Zhipeng
    Qiu, Shi
    Zhang, Mengwei
    Liu, Yanping
    Xu, Fengjing
    Song, Xinhua
    Gao, Shouhong
    Chen, Wansheng
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2022, 2022
  • [32] Bioanalysis of riluzole in human plasma by a sensitive LC-MS/MS method and its application to a pharmacokinetic study in South Indian subjects
    Narapusetti, Anjaneyulu
    Bethanabhatla, Syama Sundar
    Sockalingam, Anbazhagan
    Pilli, Nageswara Rao
    Repaka, Nagakishore
    Alla, Tejasri
    ANALYTICAL METHODS, 2014, 6 (13) : 4823 - 4830
  • [33] A sensitive LC-MS/MS method to quantify methylergonovine in human plasma and its application to a pharmacokinetic study
    Gao, Yanhui
    Sun, Qichao
    Liu, Dongming
    Ma, Bowen
    Zhao, Hengli
    Fang, Zengjun
    Wang, Haisheng
    Lou, Hongxiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1011 : 62 - 68
  • [34] A novel LC-MS/MS method for the quantification of ulipristal acetate in human plasma: Application to a pharmacokinetic study in healthy Chinese female subjects
    Peng, Chun
    Tang, Ling
    Wang, Keli
    Wang, Yan
    Ding, Li
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2020, 58 (11) : 642 - 651
  • [35] A sensitive LC-MS/MS method for the quantitative determination of biflorin in rat plasma and its application to pharmacokinetic studies
    Yang, Seung Jun
    Ryu, Jong Hoon
    Jang, Dae Sik
    Yang, Liang
    Han, Hyo-Kyung
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 115 : 272 - 276
  • [36] ANALYTICAL LC-MS/MS METHOD FOR EZETIMIBE AND ITS APPLICATION FOR PHARMACOKINETIC STUDY
    Bae, Jung-Woo
    Choi, Chang-Ik
    Park, Sang-Hun
    Jang, Choon-Gon
    Lee, Seok-Yong
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (1-4) : 141 - 152
  • [37] A simple and sensitive LC-MS/MS method for determination of miltirone in rat plasma and its application to pharmacokinetic studies
    Guo, Long
    Duan, Li
    Dong, Xin
    Dou, Li-Li
    Zhou, Ping
    Liu, E-Hu
    Li, Ping
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 973 : 33 - 38
  • [38] Development and validation of a LC-MS/MS method for the determination of clebopride and its application to a pharmacokinetics study in healthy Chinese volunteers
    Tan, Zhirong
    Ouyang, Dongsheng
    Chen, Yao
    Zhou, Gan
    Cao, Shan
    Wang, Yicheng
    Peng, Xiujuan
    Zhou, Honghao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (23): : 2072 - 2076
  • [39] Simultaneous Determination of Deoxypodophyllotoxin and Its Major Metabolites in Rat Plasma by a Sensitive LC-MS/MS Method and Its Application in a Pharmacokinetic Study
    Liu, Fei
    Chen, Yang
    Xie, Qiushi
    Liu, Li
    Xu, Ping
    Zhong, Zeyu
    Liu, Xiaodong
    CHROMATOGRAPHIA, 2016, 79 (1-2) : 53 - 61
  • [40] Sensitive method for the determination of rocilinostat in small volume mouse plasma by LC-MS/MS and its application to a pharmacokinetic study in mice
    Gupta, Manish
    Dixit, Abhishek
    Devaraj, V. C.
    Zainuddin, Mohd
    Bhamidipati, Ravi Kanth
    Hallur, Mahanandeesha S.
    Dewang, Purushottam
    Rajagopal, Sridharan
    Rajagopal, Sriram
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (07) : 1138 - 1144