A Comparison of the Accuracy Between a Digital Fabrication Workflow and a Conventional Fabrication Workflow for Occlusal Appliances: A Pilot Study

被引:2
|
作者
Lin, Rui [1 ,2 ,3 ,4 ,5 ,6 ,7 ]
Yan, Yue-Qi [1 ,2 ,3 ,4 ,5 ,6 ,8 ]
Sun, Jian [1 ,2 ,3 ,4 ,5 ,9 ,10 ]
Yu, Chun-Hua [1 ,2 ,3 ,4 ,5 ,9 ,10 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Dept Prosthodont, Sch Med, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Coll Stomatol, Shanghai, Peoples R China
[3] Natl Ctr Stomatol, Shanghai, Peoples R China
[4] Natl Clin Res Ctr Oral Dis, Shanghai, Peoples R China
[5] Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[6] Shanghai Res Inst Stomatol, Shanghai, Peoples R China
[7] Xuhui Dist Dent Clin, Dept Prosthodont, Shanghai, Peoples R China
[8] Xuhui Dist Dent Clin, Dept Gen Dent, Shanghai, Peoples R China
[9] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, 639 Zhizaoju Rd, Shanghai, Peoples R China
[10] Shanghai Jiao Tong Univ, Coll Stomatol, 639 Zhizaoju Rd, Shanghai, Peoples R China
关键词
TEMPOROMANDIBULAR DISORDERS; CLINICAL-EVALUATION; ADAPTATION;
D O I
10.11607/ijp.7947
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the accuracy of occlusal stabilization appliances fabricated by digital workflows to those fabricated by conventional workflows. Materials and Methods: In total, 10 volunteers were recruited in this single-blinded crossover study. All volunteers received two types of occlusal stabilization appliances: a digital additively manufactured stabilization splint (DS) and a conventionally fabricated splint (CS). The accuracy was assessed using a 4-point rating scale addressing two aspects of the occlusal appliances: occlusal contact and basic performance. In addition, silicone impression materials were used to assess the gap between the appliance and the maxillary arch to ensure an accurate fit. Differences were quantitatively assessed with Mann-Whitney U test and independent-sample ttest. Results: The occlusal contact rating of DS (15.90 +/- 1.73) was significantly higher than that of CS (14.10 +/- 1.10, P < .05). The basic performance rating of DS (8.70 +/- 0.48) was also significantly higher than that of CS (7.20 +/- 0.92. P < .05). Quantitative evaluation of fit accuracy revealed a statistically significant difference (P< .05), with DS (636.29 +/- 268.51 pm) being superior to CS (704.2 +/- 306.05 pm). Conclusion: The stabilization splints fabricated with a digital workflow showed better accuracy than the conventionally fabricated splints in terms of occlusal contact, basic performance, and fit accuracy. Because this is a pilot study, formal trials with a completely digital fabrication workflow will be conducted in the future.
引用
收藏
页码:501 / 507
页数:7
相关论文
共 50 条
  • [1] Digital versus conventional workflow for the fabrication of physical casts for fixed prosthodontics: A systematic review of accuracy
    Parize, Hian
    Corpa Tardelli, Juliana Dias
    Bohner, Lauren
    Sesma, Newton
    Muglia, Valdir Antonio
    dos Reis, Andrea Candido
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (01): : 25 - 32
  • [2] Fully digital workflow for the fabrication of occlusal stabilization splints based on individual mandibular movement
    Sun, Xinrong
    Feng, Yue
    Jiao, Yi
    Liu, Weicai
    JOURNAL OF DENTISTRY, 2024, 141
  • [3] Accuracy of digital and conventional impression techniques and workflow
    Seelbach, Paul
    Brueckel, Cora
    Woestmann, Bernd
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (07) : 1759 - 1764
  • [4] Accuracy of digital and conventional impression techniques and workflow
    Paul Seelbach
    Cora Brueckel
    Bernd Wöstmann
    Clinical Oral Investigations, 2013, 17 : 1759 - 1764
  • [6] SMART ASSEMBLY IN DIGITAL FABRICATION: DESIGNING WORKFLOW
    Loh, Paul
    Leggett, David
    Cameron, Timothy
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON COMPUTER-AIDED ARCHITECTURAL DESIGN RESEARCH IN ASIA (CAADRIA 2016): LIVING SYSTEMS AND MICRO-UTOPIAS: TOWARDS CONTINUOUS DESIGNING, 2016, : 755 - 764
  • [7] Complete Digital Workflow for Prosthesis Prototype Fabrication with Double Digital Scanning: Accuracy of Fit Assessment
    Papaspyridakos, Panos
    AlFulaij, Fahad
    Bokhary, Abdullah
    Sallustio, Anthony
    Chochlidakis, Konstantinos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01): : 49 - 53
  • [8] Digital workflow for auricular prosthesis fabrication with a negative mold
    Bi, Yunpeng
    Zhou, Minghao
    Wei, Hongbo
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1254 - 1258
  • [9] A Digital Workflow for the Fabrication of a Milled Removable Partial Denture
    Piao, Xing-Yu
    Jeon, Jeongho
    Shim, June-Sung
    Park, Ji-Man
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (14)
  • [10] Novel fully digital workflow for removable partial denture fabrication
    Nishiyama, Hirotaka
    Taniguchi, Asuka
    Tanaka, Shinpei
    Baba, Kazuyoshi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (01) : 98 - 103