A Comparison of the Accuracy Between a Digital Fabrication Workflow and a Conventional Fabrication Workflow for Occlusal Appliances: A Pilot Study

被引:2
|
作者
Lin, Rui [1 ,2 ,3 ,4 ,5 ,6 ,7 ]
Yan, Yue-Qi [1 ,2 ,3 ,4 ,5 ,6 ,8 ]
Sun, Jian [1 ,2 ,3 ,4 ,5 ,9 ,10 ]
Yu, Chun-Hua [1 ,2 ,3 ,4 ,5 ,9 ,10 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Dept Prosthodont, Sch Med, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Coll Stomatol, Shanghai, Peoples R China
[3] Natl Ctr Stomatol, Shanghai, Peoples R China
[4] Natl Clin Res Ctr Oral Dis, Shanghai, Peoples R China
[5] Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[6] Shanghai Res Inst Stomatol, Shanghai, Peoples R China
[7] Xuhui Dist Dent Clin, Dept Prosthodont, Shanghai, Peoples R China
[8] Xuhui Dist Dent Clin, Dept Gen Dent, Shanghai, Peoples R China
[9] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, 639 Zhizaoju Rd, Shanghai, Peoples R China
[10] Shanghai Jiao Tong Univ, Coll Stomatol, 639 Zhizaoju Rd, Shanghai, Peoples R China
关键词
TEMPOROMANDIBULAR DISORDERS; CLINICAL-EVALUATION; ADAPTATION;
D O I
10.11607/ijp.7947
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the accuracy of occlusal stabilization appliances fabricated by digital workflows to those fabricated by conventional workflows. Materials and Methods: In total, 10 volunteers were recruited in this single-blinded crossover study. All volunteers received two types of occlusal stabilization appliances: a digital additively manufactured stabilization splint (DS) and a conventionally fabricated splint (CS). The accuracy was assessed using a 4-point rating scale addressing two aspects of the occlusal appliances: occlusal contact and basic performance. In addition, silicone impression materials were used to assess the gap between the appliance and the maxillary arch to ensure an accurate fit. Differences were quantitatively assessed with Mann-Whitney U test and independent-sample ttest. Results: The occlusal contact rating of DS (15.90 +/- 1.73) was significantly higher than that of CS (14.10 +/- 1.10, P < .05). The basic performance rating of DS (8.70 +/- 0.48) was also significantly higher than that of CS (7.20 +/- 0.92. P < .05). Quantitative evaluation of fit accuracy revealed a statistically significant difference (P< .05), with DS (636.29 +/- 268.51 pm) being superior to CS (704.2 +/- 306.05 pm). Conclusion: The stabilization splints fabricated with a digital workflow showed better accuracy than the conventionally fabricated splints in terms of occlusal contact, basic performance, and fit accuracy. Because this is a pilot study, formal trials with a completely digital fabrication workflow will be conducted in the future.
引用
收藏
页码:501 / 507
页数:7
相关论文
共 50 条
  • [41] Digital versus conventional workflow for the fabrication of multiunit fixed prostheses: A systematic review and meta-analysis of vertical marginal fit in controlled in vitro studies
    Lo Russo, Lucio
    Caradonna, Giammarco
    Biancardino, Marco
    De Lillo, Alfredo
    Troiano, Giuseppe
    Guida, Laura
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (05): : 435 - 440
  • [42] Fully Digital Workflow for Planning Static Guided Implant Surgery: A Prospective Accuracy Study
    Lin, Chia-Cheng
    Wu, Ching-Zong
    Huang, Mao-Suan
    Huang, Chiung-Fang
    Cheng, Hsin-Chung
    Wang, Dayen Peter
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (04)
  • [43] A comparison of two digital techniques for the fabrication of complete removable dental prostheses: A pilot clinical study
    Schwindling, Franz Sebastian
    Stober, Thomas
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (05): : 756 - 763
  • [44] Fully Digital Workflow for Fabrication of A 3D Printed Ear Stent for Auricular Keloids: A Technique Article
    Nejat, Amir H.
    Hamdan, Suleiman
    Abrego, Isaias
    Lindsey, John T.
    Vitter, Roger
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (03): : 266 - 270
  • [45] A COMPARISON STUDY BETWEEN DISTRIBUTED AND CENTRALIZED JOB WORKFLOW EXECUTION MODELS
    Feng, Yuhong
    Cai, Wentong
    GCA 2007: PROCEEDINGS OF THE 3RD INTERNATIONAL WORKSHOP ON GRID COMPUTING AND APPLICATIONS, 2007, : 76 - 88
  • [46] A comparison of digital and conventional fabrication techniques for an esthetic maxillofacial prosthesis for the cheek and lip
    Costa-Palau, Santiago
    Clua-Palau, Anna
    Real-Voltas, Francisco
    Brufau-de Barbera, Magi
    Cabratosa-Termes, Josep
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (01): : 315 - 320
  • [47] Comparison of denture base adaptation between additive and conventional fabrication techniques
    Tosun, Osman Nuri
    Bilmenoglu, Caglar
    Ozdemir, Ali Kemal
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (03): : E64 - E70
  • [48] Fully Digital Workflow for the Fabrication of Three-Dimensionally Printed Surgical Splints for Preventing Postoperative Bleeding: A Case Report
    Inokoshi, Masanao
    Soeda, Yumika
    Akiyama, Yo
    Ueda, Kaori
    Kubota, Kazumasa
    Minakuchi, Shunsuke
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (19)
  • [49] Flow-based fabrication: An integrated computational workflow for design and digital additive manufacturing of multifunctional heterogeneously structured objects
    Duro-Royo, Jorge
    Mogas-Soldevila, Laia
    Oxman, Neri
    COMPUTER-AIDED DESIGN, 2015, 69 : 143 - 154
  • [50] Digital vs Conventional Workflow for Screw-Retained Single-Implant Crowns: A Comparison of Key Considerations
    Di Fiore, Adolfo
    Vigolo, Paolo
    Graiff, Lorenzo
    Stellini, Edoardo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (06) : 577 - 579