A Comparison of the Accuracy Between a Digital Fabrication Workflow and a Conventional Fabrication Workflow for Occlusal Appliances: A Pilot Study

被引:2
|
作者
Lin, Rui [1 ,2 ,3 ,4 ,5 ,6 ,7 ]
Yan, Yue-Qi [1 ,2 ,3 ,4 ,5 ,6 ,8 ]
Sun, Jian [1 ,2 ,3 ,4 ,5 ,9 ,10 ]
Yu, Chun-Hua [1 ,2 ,3 ,4 ,5 ,9 ,10 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Dept Prosthodont, Sch Med, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Coll Stomatol, Shanghai, Peoples R China
[3] Natl Ctr Stomatol, Shanghai, Peoples R China
[4] Natl Clin Res Ctr Oral Dis, Shanghai, Peoples R China
[5] Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[6] Shanghai Res Inst Stomatol, Shanghai, Peoples R China
[7] Xuhui Dist Dent Clin, Dept Prosthodont, Shanghai, Peoples R China
[8] Xuhui Dist Dent Clin, Dept Gen Dent, Shanghai, Peoples R China
[9] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, 639 Zhizaoju Rd, Shanghai, Peoples R China
[10] Shanghai Jiao Tong Univ, Coll Stomatol, 639 Zhizaoju Rd, Shanghai, Peoples R China
关键词
TEMPOROMANDIBULAR DISORDERS; CLINICAL-EVALUATION; ADAPTATION;
D O I
10.11607/ijp.7947
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the accuracy of occlusal stabilization appliances fabricated by digital workflows to those fabricated by conventional workflows. Materials and Methods: In total, 10 volunteers were recruited in this single-blinded crossover study. All volunteers received two types of occlusal stabilization appliances: a digital additively manufactured stabilization splint (DS) and a conventionally fabricated splint (CS). The accuracy was assessed using a 4-point rating scale addressing two aspects of the occlusal appliances: occlusal contact and basic performance. In addition, silicone impression materials were used to assess the gap between the appliance and the maxillary arch to ensure an accurate fit. Differences were quantitatively assessed with Mann-Whitney U test and independent-sample ttest. Results: The occlusal contact rating of DS (15.90 +/- 1.73) was significantly higher than that of CS (14.10 +/- 1.10, P < .05). The basic performance rating of DS (8.70 +/- 0.48) was also significantly higher than that of CS (7.20 +/- 0.92. P < .05). Quantitative evaluation of fit accuracy revealed a statistically significant difference (P< .05), with DS (636.29 +/- 268.51 pm) being superior to CS (704.2 +/- 306.05 pm). Conclusion: The stabilization splints fabricated with a digital workflow showed better accuracy than the conventionally fabricated splints in terms of occlusal contact, basic performance, and fit accuracy. Because this is a pilot study, formal trials with a completely digital fabrication workflow will be conducted in the future.
引用
收藏
页码:501 / 507
页数:7
相关论文
共 50 条
  • [21] Fabrication of a Mandibular Advancement Device Using a Fully Digital Workflow: A Clinical Report
    Piskin, Bulent
    Uyar, Alper
    Yuceer, Mine
    Topal, Sila Caglayan
    Senturk, Rahsan Atasoy
    Sutcu, Serdar
    Karakoc, Omer
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (03): : 191 - 195
  • [22] Total digital workflow in the fabrication of a partial removable dental prostheses: A case report
    Mendes, Teresa Almeida
    Marques, Duarte
    Lopes, Luis Pires
    Carames, Joao
    SAGE OPEN MEDICAL CASE REPORTS, 2019, 7
  • [23] Automating the Digital Fabrication of Concrete Formwork in Building Projects: Workflow and Case Example
    Fardhosseini, M. S.
    Abdirad, H.
    Dossick, C.
    Lee, H. W.
    DiFuria, R.
    Lohr, J.
    COMPUTING IN CIVIL ENGINEERING 2019: DATA, SENSING, AND ANALYTICS, 2019, : 360 - 367
  • [24] RAF: Robot Aware Fabrication Hand-motion Augmented Robotic Fabrication Workflow and Case Study
    Wei, Likai
    Ta, La
    Li, Liang
    Han, Yang
    Feng, Yingying
    Wang, Xin
    Xu, Zhen
    ECAADE SIGRADI 2019: ARCHITECTURE IN THE AGE OF THE 4TH INDUSTRIAL REVOLUTION, VOL 2, 2019, : 241 - 250
  • [25] Randomized clinical trial of a conventional and a digital workflow for the fabrication of interim crowns: An evaluation of treatment efficiency, fit, and the effect of clinician experience
    Cheng, Chih-Wen
    Ye, Sung-Ying
    Chien, Chia-Hui
    Chen, Chun-Jung
    Papaspyridakos, Panos
    Ko, Ching-Chang
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (01): : 73 - 81
  • [27] Accuracy of a digital workflow for bimaxillary orthognathic surgery: comparison of planned and actual outcomes
    Lee, Ker Jia Cheryl
    Tan, Suat Li
    Tan, Danny Ben Poon
    Yong, Chee Weng
    Chew, Ming Tak
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (04) : 397 - 405
  • [28] Complete Digital Workflow for Prosthesis Prototype Fabrication with the Double Digital Scanning (DDS) Technique: A Prospective Study on 16 Edentulous Maxillae
    Chochlidakis, Konstantinos
    Romeo, Davide
    Ercoli, Carlo
    Papaspyridakos, Panos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (09): : 761 - 765
  • [29] Accuracy of digital and conventional systems in locating occlusal contacts: A clinical study
    Rovira-Lastra, Bernat
    Khoury-Ribas, Laura
    Flores-Orozco, Elan -Ignacio
    Ayuso-Montero, Raul
    Chaurasia, Akhilanand
    Martinez-Gomis, Jordi
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 115 - 122
  • [30] Fabrication of Custom Post-And-Core Using a Directly Fabricated Silicone Pattern and Digital Workflow
    Farah, Ra'fat, I
    Aloraini, Abdullah S.
    Ali, Sanaa N. Al-Haj
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (07): : 631 - 635