Complete Digital Workflow for Prosthesis Prototype Fabrication with Double Digital Scanning: Accuracy of Fit Assessment

被引:10
|
作者
Papaspyridakos, Panos [1 ,2 ]
AlFulaij, Fahad [1 ]
Bokhary, Abdullah [3 ]
Sallustio, Anthony [4 ]
Chochlidakis, Konstantinos [2 ]
机构
[1] Tufts Univ, Sch Dent Med, Dept Prosthodont, One Kneeland St, Boston, MA 02111 USA
[2] Univ Rochester, Dept Prosthodont, Eastman Inst Oral Hlth, Rochester, NY USA
[3] King Abdulaziz Univ, Dept Dent Publ Hlth, Fac Dent, Jeddah, Saudi Arabia
[4] Prosthodont, Ocean Township, NJ USA
关键词
3D Printers; 3D printed casts; complete-arch implant rehabilitation; digital workflow; digital dentistry; digital impressions; intraoral scanners; DENTAL PROSTHESES; IMPLANT;
D O I
10.1111/jopr.13492
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To assess the accuracy of a complete digital workflow protocol for fabrication of printed prosthesis prototypes for maxillary immediate loading treatment. Materials and methods A maxillary stone cast with 4 abutment-level implant analogs with adequate antero-posterior spread was fabricated. This stone cast served as a reference cast and a zirconia prosthesis was also fabricated to serve as an interim prosthesis. Double digital scanning was used for digital scans of the reference cast and the interim prosthesis, respectively. An intraoral scanner (TRIOS(R) 3) was used to capture the standard tessellation language (STL) files. These STL files were then imported to computer-aided design (CAD) software (Exocad DentalCAD) and superimposed into a final design STL file that was exported to 3 different (Form 3b+, Carbon M2, Sprintray Pro95) three-dimensional (3D) printers to produce a total of 90 printed prototypes (n = 30 from each 3D printer). Two blinded clinicians assessed the accuracy of fit of each digitally fabricated prosthesis prototype on the reference cast, utilizing the screw-resistance test and radiographs. The Fisher's exact test was used to test the difference between the groups. Results Out of the 90 digitally fabricated prototypes, 86 (95.6%) presented with accurate fit. The accuracy of fit ranged from 87% (26/30) for Sprintray Pro95 to 100% (30/30) for the Form 3b+ and M2 Carbon groups . Conclusions Digitally fabricated prosthesis prototypes can be generated with a complete digital workflow leading to clinically acceptable fit, while reducing the number of appointments and treatment time. The 3D printer had an effect on the accuracy of prosthesis prototype fit.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 50 条
  • [1] Complete digital workflow for prosthesis prototype fabrication with double digital scanning: A retrospective study with 45 edentulous jaws
    Papaspyridakos, Panos
    Vazouras, Konstantinos
    Gotsis, Sotirios
    Bokhary, Abdullah
    Sicilia, Elena
    Kudara, Yukio
    Bedrossian, Armand
    Chochlidakis, Konstantinos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (07): : 571 - 578
  • [2] Complete Digital Workflow for Prosthesis Prototype Fabrication with the Double Digital Scanning (DDS) Technique: A Prospective Study on 16 Edentulous Maxillae
    Chochlidakis, Konstantinos
    Romeo, Davide
    Ercoli, Carlo
    Papaspyridakos, Panos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (09): : 761 - 765
  • [3] Reverse scan body: A complete digital workflow for prosthesis prototype fabrication
    Papaspyridakos, Panos
    Bedrossian, Armand
    Kudara, Yukio
    Ntovas, Panagiotis
    Bokhary, Abdullah
    Chochlidakis, Konstantinos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (05): : 452 - 457
  • [4] Complete digital workflow in prosthesis prototype fabrication for complete-arch implant rehabilitation: A technique
    Papaspyridakos, Panos
    Chen, Yo-wei
    Gonzalez-Gusmao, Ilenia
    Att, Wael
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (03): : 189 - 192
  • [5] Digital workflow for auricular prosthesis fabrication with a negative mold
    Bi, Yunpeng
    Zhou, Minghao
    Wei, Hongbo
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1254 - 1258
  • [6] Fabrication of an Immediate Complete Denture with Digital Workflow: A Case Report
    Macrynikola, Alkisti
    Mitsios, Christos
    Roussou, Vasilliki
    Kourtis, Stefanos
    OPEN DENTISTRY JOURNAL, 2024, 18
  • [7] Accuracy of digital duplication scanning methods for complete dentures
    Alehaideb, Abdullah
    Lin, Wei-Shao
    Levon, John A.
    Chu, Tien-Min G.
    Yang, Chao-Chieh
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025, 34 (01): : 42 - 48
  • [8] A Comparison of the Accuracy Between a Digital Fabrication Workflow and a Conventional Fabrication Workflow for Occlusal Appliances: A Pilot Study
    Lin, Rui
    Yan, Yue-Qi
    Sun, Jian
    Yu, Chun-Hua
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (04) : 501 - 507
  • [9] Complete Digital Workflow for Evaluation of the Three-Dimensional Monson's Sphere Using Digital Scanning
    Wen, Cheng
    Wang, Huan Huan
    Muhetaer, Huo Jia
    Xie, Fan
    Han, Rui
    Wu, Jin Cheng
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2025, 11 (01):
  • [10] Digital analysis of fabrication accuracy and fit in additively and subtractively manufactured implant-supported fixed complete dentures
    Maldonado, Paola
    Donmez, Mustafa Borga
    Guven, Mehmet Esad
    Schimmel, Martin
    Revilla-Leon, Marta
    Cakmak, Gulce
    Yilmaz, Burak
    JOURNAL OF DENTISTRY, 2024, 150