Accuracy and impact on quality of life of real-time continuous glucose monitoring in children with hyperinsulinaemic hypoglycaemia

被引:3
|
作者
Sivasubramanian, Madhini [1 ,2 ,3 ]
Avari, Parizad [4 ]
Gilbert, Clare [1 ]
Doodson, Louise [1 ]
Morgan, Kate [1 ]
Oliver, Nick [4 ]
Shah, Pratik [1 ,2 ,5 ]
机构
[1] Great Ormond St Hosp Children NHS Fdn Trust, Dept Paediat Endocrinol, London, England
[2] UCL, Inst Child Hlth, London WC1N, England
[3] Univ Sunderland London, Fac Hlth Sci & Wellbeing, London, England
[4] Imperial Coll London, Dept Metab Digest & Reprod, London, England
[5] Royal London Childrens Hosp, Dept Paediat Endocrinol, Barts Hlth NHS Trust, London, England
来源
基金
芬兰科学院;
关键词
hyperinsulinism; continuous glucose monitoring; hypoglycaemia; neurodevelopment; time below range; INSULIN PUMP THERAPY; AWARENESS; ADULTS;
D O I
10.3389/fendo.2023.1265076
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Continuous glucose monitoring (CGM) is the standard of care for glucose monitoring in children with diabetes, however there are limited data reporting their use in hyperinsulinaemic hypoglycaemia (HH). Here, we evaluate CGM accuracy and its impact on quality of life in children with HH.Methods: Real-time CGM (Dexcom G5 and G6) was used in children with HH aged 0-16years. Data from self-monitoring capillary blood glucose (CBG) and CGM were collected over a period of up to 28days and analysed. Quality of life was assessed by the PedsQL4.0 general module and PedsQL2.0 family impact module, completed by children and their parents/carers before and after CGM insertion. Analysis of accuracy metrics included mean absolute relative difference (MARD) and proportion of CGM values within 15, 20, and 30% or 15, 20, and 30 mg/dL of reference glucose values >100 mg/dL or <= 100 mg/dL, respectively (% 15/15, % 20/20, % 30/30). Clinical reliability was assessed with Clarke error grid (CEG) analyses.Results: Prospective longitudinal study with data analysed from 40 children. The overall MARD between reference glucose and paired CGM values (n=4,928) was 13.0% (Dexcom G5 12.8%, Dexcom G6 13.1%). The proportion of readings meeting %15/15 and %20/20 were 77.3% and 86.4%, respectively, with CEG analysis demonstrating 97.4% of all values in zones A and B. Within the hypoglycaemia range (<70 mg/dL), the median ARD was 11.4% with a sensitivity and specificity of 64.2% and 91.3%, respectively. Overall PedsQL child report at baseline and endpoint were 57.6 (50.5 - 75.8) and 87.0 (82.9 - 91.2), and for parents were 60.3 (44.8 - 66.0) and 85.3 (83.7 - 91.3), respectively (both p<0.001).Conclusion: Use of CGM for children with HH is feasible, with clinically acceptable accuracy, particularly in the hypoglycaemic range. Quality of life measures demonstrate significant improvement after CGM use. These data are important to explore use of CGM in disease indications, including neonatal and paediatric diabetes, cystic fibrosis and glycogen storage disorders.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Design and implementation of real-time continuous glucose monitoring instrument
    实时动态血糖监测器的设计与实现
    Liu, Hongying (liu_hongying@163.com), 2017, West China Hospital, Sichuan Institute of Biomedical Engineering (34):
  • [42] Real-time continuous glucose monitoring improves time spent in euglycaemia and prevents severe hypoglycaemia in type 1 diabetes mellitus patients with impaired awareness of hypoglycaemia
    van Beers, C. A. J.
    Geelhoed-Duijvestijn, P. H.
    Diamant, M.
    Kramer, M. H. H.
    DeVries, J. H.
    Snoek, F. J.
    Serne, E. H.
    DIABETOLOGIA, 2016, 59 : S98 - S98
  • [43] The use of real-time continuous glucose monitoring to correct hypoglycaemia unawareness in adolescents: initial data from a randomised trial
    Ly, Trang T.
    Hewitt, Jacqueline
    Kendall, Julie A.
    Davis, Elizabeth A.
    Jones, Timothy W.
    HORMONE RESEARCH, 2009, 72 : 51 - 51
  • [44] Hypoglycaemia documented with real-time continuous glucose sensing in a case of 'dead in bed' syndrome
    Waheed, Najeeb
    Butt, Muhammad
    Dayan, Colin
    PRACTICAL DIABETES, 2013, 30 (01) : 33 - 35
  • [45] Postprandial instead of preprandial calibration allows better accuracy of real-time continuous glucose monitoring (CGM)
    Capel, I.
    Pons, B.
    Hernando, M. E.
    Garcia, G.
    Brugues, E.
    de Leiva, A.
    Gomez, E.
    Prados, A.
    Erdozain, L.
    Rigla, M.
    DIABETOLOGIA, 2007, 50 : S419 - S419
  • [46] The Accuracy and Efficacy of Real-Time Continuous Glucose Monitoring Sensor in Chinese Diabetes Patients: A Multicenter Study
    Zhou, Jian
    Lv, Xiaofeng
    Mu, Yiming
    Wang, Xianling
    Li, Jing
    Zhang, Xingguang
    Wu, Jinxiao
    Bao, Yuqian
    Jia, Weiping
    DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (08) : 710 - 718
  • [47] Accuracy of a real-time continuous glucose monitoring system during cardiac surgery with hypothermic extracorporeal circulation
    Herzig, D.
    Vettoretti, M.
    Guensch, D. P.
    Melmer, A.
    Goerg, A. C. K.
    Kadner, A.
    Facchinetti, A.
    Vogt, A.
    Bally, L.
    DIABETOLOGIA, 2022, 65 (SUPPL 1) : S28 - S28
  • [48] Accuracy to detect neonatal hyperglycaemia using real-time continuous glucose monitoring during postoperative period
    Mohammed Abdul Wasiq
    Sushree Smita Behura
    Swaranjika Sahoo
    Santosh Kumar Panda
    European Journal of Pediatrics, 2023, 182 : 1083 - 1087
  • [49] ASSESSMENT OF THE ACCURACY OF REAL-TIME CONTINUOUS GLUCOSE MONITORING AND ITS CORRELATED FACTORS IN CRITICALLY ILL PATIENTS
    MZ Lu
    Y Kang
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [50] Accuracy to detect neonatal hyperglycaemia using real-time continuous glucose monitoring during postoperative period
    Wasiq, Mohammed Abdul
    Behura, Sushree Smita
    Sahoo, Swaranjika
    Panda, Santosh Kumar
    EUROPEAN JOURNAL OF PEDIATRICS, 2023, 182 (03) : 1083 - 1087