A multicenter evaluation of near-infrared autofluorescence imaging of parathyroid glands in thyroid and parathyroid surgery

被引:12
|
作者
Sehnem, Ludovico, Jr. [1 ]
Noureldine, Salem, I [1 ]
Avci, Seyma [1 ]
Isiktas, Gizem [1 ]
Elshamy, Mohammed [1 ]
Saito, Yoshiyuki [2 ]
Ahmed, Amr H. A. [2 ]
Tierney, Hien T. [2 ]
Trinh, Lily N. [2 ]
Karcioglu, Amanda Silver [2 ]
Cheung, Anthony Y. [2 ]
Otremba, Michael [2 ]
Krishnamurthy, Vikram [1 ]
Heiden, Katherine [1 ]
Jin, Judy [1 ]
Shin, Joyce [1 ]
Siperstein, Allan [1 ]
Zafereo, Mark [3 ]
Tufano, Ralph P. [4 ]
Randolph, Gregory W. [2 ]
Kebebew, Electron [5 ]
Milas, Mira [6 ]
Duh, Quan-Yang [7 ]
Berber, Eren [1 ]
机构
[1] Cleveland Clin, Endocrinol & Metab Inst, Dept Endocrine Surg, 9500 Euclid Ave-F20, Cleveland, OH 44195 USA
[2] Harvard Med Sch, Massachusetts Gen Hosp, Massachusetts Eye & Ear, Boston, MA 02114 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Head & Neck Surg, Div Surg, Houston, TX 77030 USA
[4] Sarasota Mem Hlth Care Syst, Head & Neck Endocrine Surg, Sarasota, FL USA
[5] Stanford Univ, Sch Med, Dept Surg, Div Gen Surg, Stanford, CA 94305 USA
[6] Univ Arizona, Banner Univ Med Ctr, Coll Med, Dept Surg,Div Endocrine Surg, Phoenix, AZ USA
[7] Univ Calif San Francisco, Dept Surg, San Francisco, CA 94143 USA
关键词
D O I
10.1016/j.surg.2022.07.057
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The usefulness of incorporating near-infrared autofluorescence into the surgical workflow of endocrine surgeons is unclear. Our aim was to develop a prospective registry and gather expert opinion on appropriate use of this technology.Methods: This was a prospective multicenter collaborative study of patients undergoing thyroidectomy and parathyroidectomy at 7 academic centers. A questionnaire was disseminated among 24 participating surgeons.Results: Overall, 827 thyroidectomy and parathyroidectomy procedures were entered into registry: 42% of surgeons found near-infrared autofluorescence useful in identifying parathyroid glands before they became apparent; 67% correlated near-infrared autofluorescence pattern to normal and abnormal glands; 38% of surgeons used near-infrared autofluorescence, rather than frozen section, to confirm parathyroid tissue; and 87% and 78% of surgeons reported near-infrared autofluorescence did not improve the success rate after parathyroidectomy or the ability to find ectopic glands, respectively. During thyroidectomy, 66% of surgeons routinely used near-infrared autofluorescence to rule out inad-vertent parathyroidectomy. However, only 36% and 45% felt near-infrared autofluorescence decreased inadvertent parathyroidectomy rates and improved ability to preserve parathyroid glands during central neck dissections, respectively.Conclusion: This survey study identified areas of greatest potential use for near-infrared auto -fluorescence, which can form the basis of future objective trials to document the usefulness of this technology.(c) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 50 条
  • [31] Spare Parathyroid Glands During Thyroid Surgery with Perioperative Autofluorescence Imaging: A Diagnostic Study
    Bellier, Alexandre
    Wazne, Yann
    Chollier, Thibaut
    Sturm, Nathalie
    Chaffanjon, Philippe
    [J]. WORLD JOURNAL OF SURGERY, 2021, 45 (09) : 2785 - 2790
  • [32] Indocyanine green as a near-infrared fluorescent agent for identifying parathyroid glands during thyroid surgery in dogs
    Suh, Yong Joon
    Choi, June Young
    Chai, Young Jun
    Kwon, Hyungju
    Woo, Jung-Woo
    Kim, Su-jin
    Kim, Kyu Hyung
    Lee, Kyu Eun
    Lim, Yong Taik
    Youn, Yeo-Kyu
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (09): : 2811 - 2817
  • [33] The Ability of Near-Infrared Autofluorescence to Protect Parathyroid Gland Function During Thyroid Surgery: A Meta-Analysis
    Wang, Bin
    Zhu, Chun-Rong
    Liu, Hong
    Yao, Xin-Min
    Wu, Jian
    [J]. FRONTIERS IN ENDOCRINOLOGY, 2021, 12
  • [34] Indocyanine green as a near-infrared fluorescent agent for identifying parathyroid glands during thyroid surgery in dogs
    Yong Joon Suh
    June Young Choi
    Young Jun Chai
    Hyungju Kwon
    Jung-Woo Woo
    Su-jin Kim
    Kyu Hyung Kim
    Kyu Eun Lee
    Yong Taik Lim
    Yeo-Kyu Youn
    [J]. Surgical Endoscopy, 2015, 29 : 2811 - 2817
  • [35] The Utility of Near-Infrared Autofluorescence for Parathyroid Gland Identification During Thyroid Surgery: A Single-Center Experience
    Richard Tjahjono
    Daniel Phung
    Michael S. Elliott
    Faruque Riffat
    Carsten E. Palme
    [J]. Indian Journal of Otolaryngology and Head & Neck Surgery, 2023, 75 : 121 - 125
  • [36] The Utility of Near-Infrared Autofluorescence for Parathyroid Gland Identification During Thyroid Surgery: A Single-Center Experience
    Tjahjono, Richard
    Phung, Daniel
    Elliott, Michael S.
    Riffat, Faruque
    Palme, Carsten E.
    [J]. INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2023, 75 (01) : 121 - 125
  • [37] Intraoperative verification of parathyroid glands in primary and secondary hyperparathyroidism using near-infrared autofluorescence (IOPA)
    Wolf, Henning W.
    Grumbeck, Bernhard
    Runkel, Norbert
    [J]. UPDATES IN SURGERY, 2019, 71 (03) : 579 - 585
  • [38] Correlation Between Near-Infrared Autofluorescence Properties and Sestamibi Uptakes of Parathyroid Glands in Primary Hyperparathyroidism
    Akgun, Ege
    Ibrahimli, Arturan
    Rahman, Mobeen
    Griffith, Christopher
    Berber, Eren
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2024,
  • [39] Intraoperative verification of parathyroid glands in primary and secondary hyperparathyroidism using near-infrared autofluorescence (IOPA)
    Henning W. Wolf
    Bernhard Grumbeck
    Norbert Runkel
    [J]. Updates in Surgery, 2019, 71 : 579 - 585
  • [40] Use of methylene blue and near-infrared fluorescence in thyroid and parathyroid surgery
    Sarah L. Hillary
    Stephanie Guillermet
    Nicola J. Brown
    Sabapathy P. Balasubramanian
    [J]. Langenbeck's Archives of Surgery, 2018, 403 : 111 - 118