A multicenter evaluation of near-infrared autofluorescence imaging of parathyroid glands in thyroid and parathyroid surgery

被引:12
|
作者
Sehnem, Ludovico, Jr. [1 ]
Noureldine, Salem, I [1 ]
Avci, Seyma [1 ]
Isiktas, Gizem [1 ]
Elshamy, Mohammed [1 ]
Saito, Yoshiyuki [2 ]
Ahmed, Amr H. A. [2 ]
Tierney, Hien T. [2 ]
Trinh, Lily N. [2 ]
Karcioglu, Amanda Silver [2 ]
Cheung, Anthony Y. [2 ]
Otremba, Michael [2 ]
Krishnamurthy, Vikram [1 ]
Heiden, Katherine [1 ]
Jin, Judy [1 ]
Shin, Joyce [1 ]
Siperstein, Allan [1 ]
Zafereo, Mark [3 ]
Tufano, Ralph P. [4 ]
Randolph, Gregory W. [2 ]
Kebebew, Electron [5 ]
Milas, Mira [6 ]
Duh, Quan-Yang [7 ]
Berber, Eren [1 ]
机构
[1] Cleveland Clin, Endocrinol & Metab Inst, Dept Endocrine Surg, 9500 Euclid Ave-F20, Cleveland, OH 44195 USA
[2] Harvard Med Sch, Massachusetts Gen Hosp, Massachusetts Eye & Ear, Boston, MA 02114 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Head & Neck Surg, Div Surg, Houston, TX 77030 USA
[4] Sarasota Mem Hlth Care Syst, Head & Neck Endocrine Surg, Sarasota, FL USA
[5] Stanford Univ, Sch Med, Dept Surg, Div Gen Surg, Stanford, CA 94305 USA
[6] Univ Arizona, Banner Univ Med Ctr, Coll Med, Dept Surg,Div Endocrine Surg, Phoenix, AZ USA
[7] Univ Calif San Francisco, Dept Surg, San Francisco, CA 94143 USA
关键词
D O I
10.1016/j.surg.2022.07.057
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The usefulness of incorporating near-infrared autofluorescence into the surgical workflow of endocrine surgeons is unclear. Our aim was to develop a prospective registry and gather expert opinion on appropriate use of this technology.Methods: This was a prospective multicenter collaborative study of patients undergoing thyroidectomy and parathyroidectomy at 7 academic centers. A questionnaire was disseminated among 24 participating surgeons.Results: Overall, 827 thyroidectomy and parathyroidectomy procedures were entered into registry: 42% of surgeons found near-infrared autofluorescence useful in identifying parathyroid glands before they became apparent; 67% correlated near-infrared autofluorescence pattern to normal and abnormal glands; 38% of surgeons used near-infrared autofluorescence, rather than frozen section, to confirm parathyroid tissue; and 87% and 78% of surgeons reported near-infrared autofluorescence did not improve the success rate after parathyroidectomy or the ability to find ectopic glands, respectively. During thyroidectomy, 66% of surgeons routinely used near-infrared autofluorescence to rule out inad-vertent parathyroidectomy. However, only 36% and 45% felt near-infrared autofluorescence decreased inadvertent parathyroidectomy rates and improved ability to preserve parathyroid glands during central neck dissections, respectively.Conclusion: This survey study identified areas of greatest potential use for near-infrared auto -fluorescence, which can form the basis of future objective trials to document the usefulness of this technology.(c) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 50 条
  • [21] Increased identification of parathyroid glands using near infrared light during thyroid and parathyroid surgery
    Jorge Falco
    Fernando Dip
    Pablo Quadri
    Martin de la Fuente
    Marcos Prunello
    Raúl J. Rosenthal
    [J]. Surgical Endoscopy, 2017, 31 : 3737 - 3742
  • [22] Detection of Parathyroid Autofluorescence Using Near-Infrared Imaging: A Multicenter Analysis of Concordance Between Different Surgeons
    Kahramangil, Bora
    Dip, Fernando
    Benmiloud, Fares
    Falco, Jorge
    de La Fuente, Martin
    Verna, Silvina
    Rosenthal, Raul
    Berber, Eren
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2018, 25 (04) : 957 - 962
  • [23] Detection of Parathyroid Autofluorescence Using Near-Infrared Imaging: A Multicenter Analysis of Concordance Between Different Surgeons
    Bora Kahramangil
    Fernando Dip
    Fares Benmiloud
    Jorge Falco
    Martin de La Fuente
    Silvina Verna
    Raul Rosenthal
    Eren Berber
    [J]. Annals of Surgical Oncology, 2018, 25 : 957 - 962
  • [24] Near-Infrared Autofluorescence Identification of Ectopic Parathyroid Lesions
    Abe, Kanako
    Takahashi, Takeshi
    Yokoyama, Yusuke
    Shodo, Ryusuke
    Ueki, Yushi
    Yamazaki, Keisuke
    Horii, Arata
    [J]. LARYNGOSCOPE, 2024, 134 (01): : 496 - 500
  • [25] In Reference to Near-Infrared Fluorescence Imaging in the Identification of Parathyroid Glands in Thyroidectomy
    Wang, Bin
    Zhu, Chun-Rong
    Wu, Jian
    [J]. LARYNGOSCOPE, 2021, 131 (05): : E1748 - E1748
  • [26] The Accuracy of Near Infrared Autofluorescence in Identifying Parathyroid Gland During Thyroid and Parathyroid Surgery: A Meta-Analysis
    Wang, Bin
    Zhu, Chun-Rong
    Liu, Hong
    Yao, Xin-Min
    Wu, Jian
    [J]. FRONTIERS IN ENDOCRINOLOGY, 2021, 12
  • [27] Spare Parathyroid Glands During Thyroid Surgery with Perioperative Autofluorescence Imaging: A Diagnostic Study
    Alexandre Bellier
    Yann Wazne
    Thibaut Chollier
    Nathalie Sturm
    Philippe Chaffanjon
    [J]. World Journal of Surgery, 2021, 45 : 2785 - 2790
  • [28] Can near-infrared autofluorescence imaging be used for intraoperative confirmation of parathyroid tissue?
    Berber, Eren
    Akbulut, Serkan
    [J]. JOURNAL OF SURGICAL ONCOLOGY, 2021, 124 (07) : 1008 - 1013
  • [29] Label-free Intraoperative Parathyroid Localization With Near-Infrared Autofluorescence Imaging
    McWade, Melanie A.
    Paras, Constantine
    White, Lisa M.
    Phay, John E.
    Solorzano, Carmen C.
    Broome, James T.
    Mahadevan-Jansen, Anita
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2014, 99 (12): : 4574 - 4580
  • [30] Near-infrared fluorescent imaging techniques for the detection and preservation of parathyroid glands during endocrine surgery
    Demarchi, Marco Stefano
    Karenovics, Wolfram
    Bedat, Benoit
    Triponez, Frederic
    [J]. INNOVATIVE SURGICAL SCIENCES, 2022, 7 (3-4): : 87 - 98