Intraoperative verification of parathyroid glands in primary and secondary hyperparathyroidism using near-infrared autofluorescence (IOPA)

被引:31
|
作者
Wolf, Henning W. [1 ,2 ]
Grumbeck, Bernhard [3 ]
Runkel, Norbert [4 ,5 ]
机构
[1] Schwarzwald Baar Klinikum Villingen Schwenningen, Dept Gen Surg, Klin Str 11, D-78052 Villingen Schwenningen, Germany
[2] Kantonsspital Aarau AG, Tellstr 25, CH-5001 Aarau, Switzerland
[3] Klinikum Sankt Elisabeth, Dept Surg, St Elisabeth Str 23, D-94315 Straubing, Germany
[4] Schwarzwald Baar Klinikum Villingen Schwenningen, Klin Str 11, D-78052 Villingen Schwenningen, Germany
[5] Sana Klinikum Offenbach, Starkenburgring 66, D-63069 Offenbach, Germany
关键词
Parathyroid surgery; Hyperparathyroidism; Endocrine surgery; Near-infrared autofluorescence; SENSING RECEPTOR EXPRESSION; METHYLENE-BLUE; IDENTIFICATION; FLUORESCENCE; LOCALIZATION; SURGERY; UTILITY;
D O I
10.1007/s13304-019-00652-1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Intraoperative verification of parathyroid glands relies on visual identification by the surgeon and, with some time delay, on serum parathormon measurements and frozen section. Fluorescence imaging, however, is an instant on-table method for direct visualization of parathyroid tissue which is known to exhibit increased autofluorescence intensity when exposed to near-infrared light. In this retrospective observational study, we evaluate the clinical use of this method in a series of patients with primary and secondary hyperparathyroidism. A total of 66 adenomatous and hyperplastic parathyroid glands were examined with intraoperative autofluorescence in 39 patients with primary and secondary hyperparathyroidism using a near-infrared system (KARL STORZ GmbH & Co. KG). The specimens were verified by conventional histology. Fifty-seven of 66 histologically proven adenomatous/hyperplastic glands exhibited autofluorescence. The sensitivity of near-infrared autofluorescence was 0.9 in pHPT and 0.83 in sHPT, respectively. The positive predictive value was 0.93 in pHPT and 1.0 in sHPT, respectively. Near-infrared autofluorescence guidance presents an innovative instant surgical imaging tool with sensitivity in detecting adenomatous and hyperplastic parathyroid glands comparable to current intraoperative methods. Due to its elegant and tracer-free design combined with low follow-up costs, this method can be useful for routine use.
引用
收藏
页码:579 / 585
页数:7
相关论文
共 50 条
  • [1] Intraoperative verification of parathyroid glands in primary and secondary hyperparathyroidism using near-infrared autofluorescence (IOPA)
    Henning W. Wolf
    Bernhard Grumbeck
    Norbert Runkel
    Updates in Surgery, 2019, 71 : 579 - 585
  • [2] Near-Infrared Autofluorescence Signature: A New Parameter for Intraoperative Assessment of Parathyroid Glands in Primary Hyperparathyroidism
    Akgun, Ege
    Ibrahimli, Arturan
    Berber, Eren
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2025, 240 (01) : 84 - 93
  • [3] Use of near-infrared autofluorescence for intraoperative identification of parathyroid glands in primary hyperparathyroidism-A randomized study
    Gimbel, Sarah
    Bartsch, Detlef K.
    CHIRURGIE, 2023,
  • [4] Use of Near-Infrared Autofluorescence for intraoperative Identification of Parathyroid Glands in Patients with primary Hyperparathyroidism - A randomized Study
    Gimbel, Sarah
    Bartsch, Detlef K.
    CHIRURGIE, 2023, 94 (11): : 959 - 960
  • [5] Intraoperative near-infrared autofluorescence imaging of parathyroid glands
    Ladurner, Roland
    Sommerey, Sandra
    Al Arabi, Nora
    Hallfeldt, Klaus K. J.
    Stepp, Herbert
    Gallwas, Julia K. S.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (08): : 3140 - 3145
  • [6] Intraoperative near-infrared autofluorescence imaging of parathyroid glands
    Roland Ladurner
    Sandra Sommerey
    Nora Al Arabi
    Klaus K. J. Hallfeldt
    Herbert Stepp
    Julia K. S. Gallwas
    Surgical Endoscopy, 2017, 31 : 3140 - 3145
  • [7] Correlation Between Near-Infrared Autofluorescence Properties and Sestamibi Uptakes of Parathyroid Glands in Primary Hyperparathyroidism
    Akgun, Ege
    Ibrahimli, Arturan
    Rahman, Mobeen
    Griffith, Christopher
    Berber, Eren
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2024, 171 (05) : 1341 - 1348
  • [8] Near-infrared autofluorescence for the detection of parathyroid glands
    Paras, Constantine
    Keller, Matthew
    White, Lisa
    Phay, John
    Mahadevan-Jansen, Anita
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (06)
  • [9] Intraoperative Near-Infrared Autofluorescence and Indocyanine Green Imaging to Identify Parathyroid Glands: A Comparison
    Lerchenberger, Max
    Al Arabi, Norah
    Gallwas, Julia K. S.
    Stepp, Herbert
    Hallfeldt, Klaus K. J.
    Ladurner, Roland
    INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2019, 2019
  • [10] Near-Infrared Autofluorescence or Intraoperative Parathyroid Hormone Determination as a Surgical Support Tool in Primary Hyperparathyroidism: Too Close to Call?
    Indelicato, Pietro
    Barbieri, Diego
    Salerno, Emilio
    Tettamanti, Alberto
    Guizzardi, Mathilda Tersilla
    Galli, Andrea
    Frattini, Francesco
    Giordano, Leone
    Bussi, Mario
    Dionigi, Gianlorenzo
    CANCERS, 2024, 16 (23)