Biomechanical design optimization of proximal humerus locked plates: A review

被引:3
|
作者
Zdero, Radovan [1 ]
Brzozowski, Pawel [1 ,3 ]
Schemitsch, Emil H. [1 ,2 ]
机构
[1] Victoria Hosp, Orthopaed Biomech Lab, London, ON, Canada
[2] Western Univ, Div Orthopaed Surg, London, ON, Canada
[3] Victoria Hosp, Room A6-144,800 Commissioners Rd East, London, ON N6A 5W9, Canada
关键词
Biomechanics; Optimization; Proximal humerus; Locked plates; Review; SURGICAL NECK FRACTURES; LOCKING PLATE; MEDIAL SUPPORT; INTERNAL-FIXATION; STAINLESS-STEEL; CALCAR SCREWS; IN-VITRO; BONE; STABILITY; IMPLANTS;
D O I
10.1016/j.injury.2023.111247
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Proximal humerus locked plates (PHLPs) are widely used for fracture surgery. Yet, non-union, malunion, infection, avascular necrosis, screw cut-out (i.e., perforation), fixation failure, and re-operation occur. Most biomechanical investigators compare a specific PHLP configuration to other implants like nonlocked plates, nails, wires, and arthroplasties. However, it is unknown whether the PHLP configuration is biomechanically optimal according to some well-known biomechanical criteria. Therefore, this is the first review of the systematic optimization of plate and/or screw design variables for improved PHLP biomechanical performance.Methods: The PubMed website was searched for papers using the terms "proximal humerus" or "shoulder" plus "biomechanics/biomechanical" plus "locked/locking plates". PHLP papers were included if they were (a) optimization studies that systematically varied plate and screw variables to determine their influence on PHLP's biomechanical performance; (b) focused on plate and screw variables rather than augmentation techniques (i.e., extra implants, bone struts, or cement); (c) published after the year 2000 signaling the commercial availability of locked plate technology; and (d) written in English.Results: The 41 eligible papers involved experimental testing and/or finite element modeling. Plate variables investigated by these papers were geometry, material, and/or position, while screw variables studied were number, distribution, angle, size, and/or threads. Numerical outcomes given by these papers included stiffness, strength, fracture motion, bone and implant stress, and/or the number of loading cycles to failure. But, no paper fully optimized any plate or screw variable for a PHLP by simultaneously applying four well-established biomechanical criteria: (a) allow controlled fracture motion for early callus generation; (b) reduce bone and implant stress below the material's ultimate stress to prevent failure; (c) maintain sufficient bone-plate interface stress to reduce bone resorption (i.e., stress shielding); and (d) increase the number of loading cycles before failure for a clinically beneficial lifespan (i.e., fatigue life). Finally, this review made suggestions for future work, identified clinical implications, and assessed the quality of the papers reviewed.Conclusions: Applying biomechanical optimization criteria can assist biomedical engineers in designing or evaluating PHLPs, so orthopaedic surgeons can have superior PHLP constructs for clinical use.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures
    Kotler, Joshua A.
    Zuppke, Julia N.
    Abraham, Vivek M.
    Sanville, Jennifer A.
    Nabet, Austin C.
    Carofino, Bradley
    Gardner, Michael J.
    Smith, Christopher S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (09) : E355 - E360
  • [22] Locked Plate Fixation for Fractures of the Proximal Humerus
    Ricci, William M.
    TECHNIQUES IN ORTHOPAEDICS, 2007, 22 (04) : 192 - 196
  • [23] Biomechanical design of a new proximal humerus fracture plate using alternative materials
    Islam, Sabrina
    Dembowski, Mitchell
    Schemitsch, Emil H.
    Bougherara, Habiba
    Bagheri, Z. Shaghayegh
    Zdero, Radovan
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024,
  • [24] Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review
    Jabran, Ali
    Peach, Chris
    Ren, Lei
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [25] Enhancing fixation stability in proximal humerus fractures: screw orientation optimization in PHILOS plates through finite element analysis and biomechanical testing
    Jichao Liu
    Ziyan Zhang
    Peng Li
    Chengdong Piao
    Scientific Reports, 14 (1)
  • [26] Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review
    Ali Jabran
    Chris Peach
    Lei Ren
    BioMedical Engineering OnLine, 17
  • [27] Parametric Design Optimisation of Proximal Humerus Plates Based on Finite Element Method
    Ali Jabran
    Chris Peach
    Zhenmin Zou
    Lei Ren
    Annals of Biomedical Engineering, 2019, 47 : 601 - 614
  • [28] Parametric Design Optimisation of Proximal Humerus Plates Based on Finite Element Method
    Jabran, Ali
    Peach, Chris
    Zou, Zhenmin
    Ren, Lei
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (02) : 601 - 614
  • [29] Arthroscopic removal of proximal humerus locking plates
    Dines, Joshua S.
    Hettrich, Carolyn M.
    Kelly, Bryan T.
    Savoie, Felix H., III
    Lorich, Dean G.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (03) : 409 - 411
  • [30] Arthroscopic removal of proximal humerus locking plates
    Joshua S. Dines
    Carolyn M. Hettrich
    Bryan T. Kelly
    Felix H. Savoie III
    Dean G. Lorich
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 409 - 411