Dynamic performance analysis and thermal modelling of a novel two-phase spray cooled rack system for data center cooling

被引:17
|
作者
Liu, Pengfei [1 ]
Kandasamy, Ranjith [1 ]
Ho, Jin Yao [1 ]
Wong, Teck Neng [1 ]
Toh, Kok Chuan [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, 50 Nanyang Ave, Singapore 639798, Singapore
基金
新加坡国家研究基金会;
关键词
Spray cooled rack; Dynamic study; Thermal modelling; Data center; Energy saving;
D O I
10.1016/j.energy.2023.126835
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cooling systems in information technology (IT) equipment account for the greatest share of direct energy consumption in data centers. Conventional air-cooling schemes are thermally inefficient and energy intensive as they require large temperature difference between heat source and cooling medium. To overcome the aforementioned drawbacks of air-cooling, a "chillerless" novel spraying architecture which has the capability of performing high heat flux cooling, is highly scalable and easily adaptable by modern data centers is proposed in this paper. To demonstrate the scalability and performance of this new cooling scheme, a full-scale spray cooled rack system which has the capacity of housing up to 12 server units is developed. The dynamic performance of the spray cooled rack system under variable ambient temperature is studied. It is found that the ambient temperature strongly affects the spray cooling performances and the chamber pressure stability. A grey box model of the system is established. The newly developed model has successfully predicted the temperature variation on both the water side and spray cooling side with reasonable accuracy. Our model sets the foundation for predictive control of the chamber pressure and workload management of the spray cooling scheme for application in largescale data centers.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Thermal Performance of a Cylindrical Lithium-Ion Battery Module Cooled by Two-Phase Refrigerant Circulation
    Lin, Bichao
    Cen, Jiwen
    Jiang, Fangming
    ENERGIES, 2021, 14 (23)
  • [42] Evaluation and Optimization of a Two-Phase Liquid-Immersion Cooling System for Data Centers
    Liu, Cheng
    Yu, Hang
    ENERGIES, 2021, 14 (05)
  • [43] Thermal performance of non-metallic two-phase cold plates for humanoid robot cooling
    Hwang, Kyudae
    Lee, Suk Won
    Karng, Sarng Woo
    Kim, Seo Young
    2008 11TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, VOLS 1-3, 2008, : 6 - +
  • [44] Two-Phase Immersion Cooling of Microprocessors with Electroplated Porous Heat Spreaders: Thermal Performance and Reliability
    Al Sayed, Chady
    Ghaffari, Omidreza
    Larimi, Yaser Nabavi
    Grenier, Francis
    Jasmin, Simon
    Frechette, Luc
    Sylvestre, Julien
    PROCEEDINGS OF THE TWENTIETH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM 2021), 2021, : 410 - 416
  • [45] System Analysis and Comparison Between a 2 MW Conventional Liquid Cooling System and a Novel Two-Phase Cooling System for Fuel Cell-Powered Aircraft
    van Gerner, Henk Jan
    Luten, Tim
    Resende, William
    Muehlthaler, Georg
    Buntz, Marcus-Benedict
    ENERGIES, 2025, 18 (04)
  • [46] Cooling performance of a pump-driven two phase cooling system for free cooling in data centers
    Ma, Yuezheng
    Ma, Guoyuan
    Zhang, Shuang
    Zhou, Feng
    APPLIED THERMAL ENGINEERING, 2016, 95 : 143 - 149
  • [48] A high-performance Two-Phase Multipath scheme for data-center networks
    Ferraz, Lyno Henrique G.
    Laufer, Rafael
    Mattos, Diogo M. F.
    Duarte, Otto Carlos M. B.
    Pujolle, Guy
    COMPUTER NETWORKS, 2017, 112 : 36 - 51
  • [49] Adaptative two-phase thermal circulation system for complex-shaped electronic device cooling
    Xu, Wenjun
    Cui, Jiarong
    Ma, Yao
    Hu, Zhanpeng
    Qi, Yuyang
    Li, Xinying
    Zhong, Yuchen
    Luo, Tao
    Chu, Xuyang
    Wu, Linjing
    Ling, Weisong
    Zhou, Wei
    NATURE COMMUNICATIONS, 2025, 16 (01)
  • [50] Thermal performance of a two-phase closed thermosyphon for waste heat recovery system
    Kannan M.
    Natarajan E.
    Journal of Applied Sciences, 2010, 10 (05) : 413 - 418