Radio-luminescent imaging for rapid, high-resolution eye plaque loading verification

被引:0
|
作者
Yan, Huagang [1 ]
De Jean, Paul [2 ]
Grafil, Elliot [2 ]
Ashraf, Ramish [3 ]
Niedermayr, Thomas [3 ]
Astrahan, Melvin [4 ]
Mruthyunjaya, Prithvi [5 ]
Beadle, Beth [3 ]
Xing, Lei [3 ]
Liu, Wu [3 ]
机构
[1] Capital Med Univ, Sch Biomed Engn, Beijing, Peoples R China
[2] Luca Med Syst Inc, Palo Alto, CA USA
[3] Stanford Univ, Sch Med, Dept Radiat Oncol, 875 Blake Wilbur Dr,MC 5847, Stanford, CA 94305 USA
[4] Eye Plaque LLC, Los Alamitos, CA USA
[5] Stanford Univ, Dept Ophthalmol, Sch Med, Stanford, CA 94305 USA
关键词
eye plaque brachytherapy; gamma evaluation; Monte Carlo simulation; quality assurance; radioluminescent imaging; I-125; PLAQUE; DOSIMETRY; AAPM; SIMULATION; TRANSPORT; MELANOMA; KERMA; FILM;
D O I
10.1002/mp.16003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Eye plaque brachytherapy is currently an optimal therapy for intraocular cancers. Due to the lack of an effective and practical technique to measure the seed radioactivity distribution, current quality assurance (QA) practice according to the American Association of Physicists in Medicine TG129 only stipulates that the plaque assembly be visually inspected. Consequently, uniform seed activity is routinely adopted to avoid possible loading mistakes of differential seed loading. However, modulated dose delivery, which represents a general trend in radiotherapy to provide more personalized treatment for a given tumor and patient, requires differential activities in the loaded seeds. Purpose In this study, a fast and low-cost radio-luminescent imaging and dose calculating system to verify the seed activity distribution for differential loading was developed. Methods A proof-of-concept system consisting of a thin scintillator sheet coupled to a camera/lens system was constructed. A seed-loaded plaque can be placed directly on the scintillator surface with the radioactive seeds facing the scintillator. The camera system collects the radioluminescent signal generated by the scintillator on its opposite side. The predicted dose distribution in the scintillator's sensitive layer was calculated using a Monte Carlo simulation with the planned plaque loading pattern of I-125 seeds. Quantitative comparisons of the distribution of relative measured signal intensity and that of the relative predicted dose in the sensitive layer were performed by gamma analysis, similar to intensity-modulated radiation therapy QA. Results Data analyses showed high gamma (3%/0.3 mm, global, 20% threshold) passing rates for correct seed loadings and low passing rates with distinguished high gamma value area for incorrect loadings, indicating that possible errors may be detected. The measurement and analysis only required a few extra minutes, significantly shorter than the time to assay the extra verification seeds the physicist already must perform as recommended by TG129. Conclusions Radio-luminescent QA can be used to facilitate and assure the implementation of intensity-modulated, customized plaque loading.
引用
收藏
页码:142 / 151
页数:10
相关论文
共 50 条
  • [21] In vivo middle cerebral artery plaque imaging by high-resolution MRI
    Klein, I. F.
    Lavallee, P. C.
    Touboul, P. -J.
    Schouman-Claeys, E.
    Amarenco, P.
    NEUROLOGY, 2006, 67 (02) : 327 - 329
  • [22] Advanced CLARITY for rapid and high-resolution imaging of intact tissues
    Tomer, Raju
    Ye, Li
    Hsueh, Brian
    Deisseroth, Karl
    NATURE PROTOCOLS, 2014, 9 (07) : 1682 - 1697
  • [23] Advanced CLARITY for rapid and high-resolution imaging of intact tissues
    Raju Tomer
    Li Ye
    Brian Hsueh
    Karl Deisseroth
    Nature Protocols, 2014, 9 : 1682 - 1697
  • [24] Rapid Quality Assurance for Eye Plaques Using a High-Resolution Gamma-Ray Imaging Scintigraphy System
    Rehman, M.
    Hamilton, R.
    Stea, B.
    Johnson, T.
    Furenlid, L.
    Miller, B.
    MEDICAL PHYSICS, 2022, 49 (06) : E467 - E467
  • [25] Verification of Rapid Refresh and High-Resolution Rapid Refresh Model Variables in Tornadic Tropical Cyclones
    Macdonald, Leland M.
    Nowotarski, Christopher J.
    WEATHER AND FORECASTING, 2023, 38 (05) : 655 - 675
  • [26] High-resolution imaging of electrochemical doping and dedoping processes in luminescent conjugated polymers
    Hu, YF
    Tracy, C
    Gao, J
    APPLIED PHYSICS LETTERS, 2006, 88 (12)
  • [27] A Novel Technology for Simultaneous Tensile Loading and High-Resolution Imaging of Cells
    Bao-Ngoc B. Nguyen
    Joshua Chetta
    Sameer B. Shah
    Cellular and Molecular Bioengineering, 2012, 5 : 504 - 513
  • [28] A Novel Technology for Simultaneous Tensile Loading and High-Resolution Imaging of Cells
    Nguyen, Bao-Ngoc B.
    Chetta, Joshua
    Shah, Sameer B.
    CELLULAR AND MOLECULAR BIOENGINEERING, 2012, 5 (04) : 504 - 513
  • [29] Boundary Layer and Surface Verification of the High-Resolution Rapid Refresh, Version 3
    Fovell, Robert G.
    Gallagher, Alex
    WEATHER AND FORECASTING, 2020, 35 (06) : 2255 - 2278
  • [30] Modeling human eye aberrations and their compensation for high-resolution retinal imaging
    Zhu, LJ
    Bartsch, DU
    Freeman, WR
    Sun, PC
    Fainman, Y
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (11) : 827 - 839