Radio-luminescent imaging for rapid, high-resolution eye plaque loading verification

被引:0
|
作者
Yan, Huagang [1 ]
De Jean, Paul [2 ]
Grafil, Elliot [2 ]
Ashraf, Ramish [3 ]
Niedermayr, Thomas [3 ]
Astrahan, Melvin [4 ]
Mruthyunjaya, Prithvi [5 ]
Beadle, Beth [3 ]
Xing, Lei [3 ]
Liu, Wu [3 ]
机构
[1] Capital Med Univ, Sch Biomed Engn, Beijing, Peoples R China
[2] Luca Med Syst Inc, Palo Alto, CA USA
[3] Stanford Univ, Sch Med, Dept Radiat Oncol, 875 Blake Wilbur Dr,MC 5847, Stanford, CA 94305 USA
[4] Eye Plaque LLC, Los Alamitos, CA USA
[5] Stanford Univ, Dept Ophthalmol, Sch Med, Stanford, CA 94305 USA
关键词
eye plaque brachytherapy; gamma evaluation; Monte Carlo simulation; quality assurance; radioluminescent imaging; I-125; PLAQUE; DOSIMETRY; AAPM; SIMULATION; TRANSPORT; MELANOMA; KERMA; FILM;
D O I
10.1002/mp.16003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Eye plaque brachytherapy is currently an optimal therapy for intraocular cancers. Due to the lack of an effective and practical technique to measure the seed radioactivity distribution, current quality assurance (QA) practice according to the American Association of Physicists in Medicine TG129 only stipulates that the plaque assembly be visually inspected. Consequently, uniform seed activity is routinely adopted to avoid possible loading mistakes of differential seed loading. However, modulated dose delivery, which represents a general trend in radiotherapy to provide more personalized treatment for a given tumor and patient, requires differential activities in the loaded seeds. Purpose In this study, a fast and low-cost radio-luminescent imaging and dose calculating system to verify the seed activity distribution for differential loading was developed. Methods A proof-of-concept system consisting of a thin scintillator sheet coupled to a camera/lens system was constructed. A seed-loaded plaque can be placed directly on the scintillator surface with the radioactive seeds facing the scintillator. The camera system collects the radioluminescent signal generated by the scintillator on its opposite side. The predicted dose distribution in the scintillator's sensitive layer was calculated using a Monte Carlo simulation with the planned plaque loading pattern of I-125 seeds. Quantitative comparisons of the distribution of relative measured signal intensity and that of the relative predicted dose in the sensitive layer were performed by gamma analysis, similar to intensity-modulated radiation therapy QA. Results Data analyses showed high gamma (3%/0.3 mm, global, 20% threshold) passing rates for correct seed loadings and low passing rates with distinguished high gamma value area for incorrect loadings, indicating that possible errors may be detected. The measurement and analysis only required a few extra minutes, significantly shorter than the time to assay the extra verification seeds the physicist already must perform as recommended by TG129. Conclusions Radio-luminescent QA can be used to facilitate and assure the implementation of intensity-modulated, customized plaque loading.
引用
收藏
页码:142 / 151
页数:10
相关论文
共 50 条
  • [31] High-resolution ultrasonic imaging of blood flow in the anterior segment of the eye
    Silverman, RH
    Kruse, DE
    Coleman, DJ
    Ferrara, KW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (07) : 1373 - 1381
  • [32] High-resolution Imaging of Two Radio Quasars at the End of the Reionization Epoch
    Perger, Krisztina
    Zhang, Yingkang
    Frey, Sandor
    An, Tao
    Gabanyi, Krisztina E.
    Gurvits, Leonid, I
    Hwang, Chorng-Yuan
    Koptelova, Ekaterina
    Paragi, Zsolt
    Wang, Ailing
    15TH EUROPEAN VLBI NETWORK MINI-SYMPOSIUM AND USERS' MEETING, 2023,
  • [33] Fifteen years of high-resolution radio imaging of supernova 1987A
    Gaensler, B. M.
    Staveley-Smith, L.
    Manchester, R. N.
    Kesteven, M. J.
    Ball, L.
    Tzioumis, A. K.
    SUPERNOVA 1987A: 20 YEARS AFTER: SUPERNOVAE AND GAMMA-RAY BURSTERS, 2007, 937 : 86 - +
  • [34] RAPID HIGH-RESOLUTION CYTOMETRY
    WIED, GL
    BARTELS, PH
    DYTCH, HE
    PISHOTTA, FT
    BIBBO, M
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1982, 4 (04): : 257 - 262
  • [35] A rapid and automated relocation method of an AFM probe for high-resolution imaging
    Zhou, Peilin
    Yu, Haibo
    Shi, Jialin
    Jiao, Niandong
    Wang, Zhidong
    Wang, Yuechao
    Liu, Lianqing
    NANOTECHNOLOGY, 2016, 27 (39)
  • [36] Rapid high-resolution volumetric imaging via laser ablation delayering and confocal imaging
    Phoulady, Adrian
    May, Nicholas
    Choi, Hongbin
    Suleiman, Yara
    Shahbazmohamadi, Sina
    Tavousi, Pouya
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [37] Rapid high-resolution volumetric imaging via laser ablation delayering and confocal imaging
    Adrian Phoulady
    Nicholas May
    Hongbin Choi
    Yara Suleiman
    Sina Shahbazmohamadi
    Pouya Tavousi
    Scientific Reports, 12
  • [38] A HIGH-RESOLUTION DUO FOR EYE RELIEF
    MIASTKOWSKI, S
    BYTE, 1991, 16 (04): : 60 - +
  • [39] A HIGH-RESOLUTION AERIAL FOR RADIO ASTRONOMY
    CHRISTIANSEN, WN
    NATURE, 1953, 171 (4358) : 831 - 833
  • [40] STANFORDS HIGH-RESOLUTION RADIO INTERFEROMETER
    BRACEWELL, RN
    COLVIN, RS
    PRICE, KM
    THOMPSON, AR
    SKY AND TELESCOPE, 1971, 42 (01): : 4 - +