Towards 50 years of platelet function analyser (PFA) testing

被引:11
|
作者
Favaloro, Emmanuel J. [1 ,2 ,3 ]
Pasalic, Leonardo [1 ,2 ,4 ]
Lippi, Giuseppe [5 ,6 ]
机构
[1] NSW Hlth Pathol, Inst Clin Pathol & Med Res ICPMR, Haematol, Westmead, NSW 2145, Australia
[2] Sydney Ctr Thrombosis & Haemostasis, Westmead, NSW, Australia
[3] Charles Sturt Univ, Fac Sci & Hlth, Wagga Wagga, NSW, Australia
[4] Univ Sydney, Westmead Clin Sch, Westmead, NSW, Australia
[5] Univ Verona, Sect Clin Biochem, Verona, Italy
[6] Univ Verona, Sch Med, Verona, Italy
关键词
in vitro bleeding time; PFA-100; PFA-200; platelet function analyser; LIGHT TRANSMITTANCE AGGREGOMETRY; VON-WILLEBRAND-DISORDER; BLEEDING-TIME PFA-100; ABO BLOOD-GROUP; IN-VITRO; LABORATORY DIAGNOSIS; CLINICAL UTILITY; CLOSURE TIMES; COAGULATION; PARAMETERS;
D O I
10.1515/cclm-2022-0666
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The platelet function analyser (PFA) is a prevalent platelet function screening instrument, and comes in two models-the original PFA-100 and the contemporary PFA-200. The instruments have 'identical' output, being a 'closure time' (CT). Moreover, normal reference ranges provided by the manufacturer, for the specific test cartridges, are the same for both models. There are three different types of test cartridge: collagen/epinephrine (C/Epi), collagen/adenosine diphosphate (C/ADP), and "Innovance PFA P2Y" (only available in certain geographical locations). The PFA-100 was released in the mid 1990s, and so is approaching 50 years of age. The PFA-200, released in some locations in the mid 2010s, is destined to eventually replace the PFA-100, but is not yet available in the USA. The test system is highly sensitive to von Willebrand disease (VWD; C/Epi and C/ADP) and to aspirin therapy (C/Epi only), but only has moderate sensitivity to defects in platelet function and/or deficiencies in platelet number. Accordingly, recommendations for use for screening platelet function vary according to user experience. Some workers have alternatively used the PFA to assess thrombosis risk or pre-operative bleeding risk. In this review, we provide an overview of the history of PFA, and summarise its current clinical utility.
引用
收藏
页码:851 / 860
页数:10
相关论文
共 50 条
  • [41] Platelet function (measured by Platelet Function Analyser-100) and obstructive sleep apnoea
    West, S
    Segal, H
    Harrison, P
    Stradling, J
    JOURNAL OF SLEEP RESEARCH, 2005, 14 (03) : 325 - 327
  • [42] EVALUATION OF PLATELET FUNCTION DURING PREGNANCY USING THE PLATELET FUNCTION ANALYZER (PFA-100)
    Kousoulakou, A.
    Perdiou, A.
    Papadopoulou, G.
    Leveta, G.
    Trigka, A.
    Statherou, K.
    Andromida, M.
    Tsoukanas, V.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2009, 94 : 530 - 530
  • [43] Platelet function analyzer (PFA-100)™ closure time in the evaluation of platelet disorders and platelet function:: a rebuttal
    Serebruany, V. L.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (06) : 1428 - 1429
  • [44] Platelet function analyzer (PFA)-100® closure time in the evaluation of platelet disorders and platelet function:: reply to a rebuttal
    Hayward, CPM
    Harrison, P
    Cattaneo, M
    Ortel, TL
    Rao, AK
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (06) : 1432 - 1432
  • [45] Platelet function analyser (PFA-100) results and von Willebrand factor deficiency: a 16-year 'real-world' experience
    Ardillon, L.
    Ternisien, C.
    Fouassier, M.
    Sigaud, M.
    Lefrancois, A.
    Pacault, M.
    Ribeyrol, O.
    Fressinaud, E.
    Boisseau, P.
    Trossaert, M.
    HAEMOPHILIA, 2015, 21 (05) : 646 - 652
  • [46] The clinical utility of Multiplate analyser measurement in platelet function testing following stroke and transient ischaemic attack
    Mannu, Gurdeep S.
    Macartney, Alistair
    Lambert, Jonathan R. A.
    Bettencourt-Silva, Joao H.
    Lawn, Mark
    Lyall, Hamish
    Metcalf, Anthony Kneale
    Potter, John F.
    Wood, John
    Clark, Allan
    Baglin, Trevor
    Myint, Phyo Kyaw
    Bowles, Kristian M.
    EUROPEAN JOURNAL OF HAEMATOLOGY, 2015, 94 (02) : 138 - 144
  • [47] Circadian variation of platelet function measured with the PFA-100®
    Feuring, M.
    Wehling, M.
    Ruf, A.
    Schultz, A.
    PLATELETS, 2009, 20 (07) : 466 - 470
  • [48] Platelet function analyser in diagnosis of von Willebrand disease
    Smejkal, P.
    Zavrelova, J.
    Zapletal, O.
    Vangenechten, I.
    Gadisseur, A.
    Romanova, G.
    Polak, P.
    Blatny, J.
    Michiels, J. J.
    Penka, M.
    HAEMOPHILIA, 2019, 25 : 156 - 156
  • [49] Evaluation of the hemostatic function of stored platelet concentrates using the platelet function analyzer (PFA-100™)
    Borzini, P
    Lazzaro, A
    Mazzucco, L
    HAEMATOLOGICA, 1999, 84 (12) : 1104 - 1109
  • [50] Platelet function assessment in various thrombocytopenic states using the platelet function analyzer (PFA-100®)
    Carcao, MD
    Blanchette, VS
    Drouin, J
    Wakefield, C
    Butchart, S
    He, L
    Rand, ML
    THROMBOSIS AND HAEMOSTASIS, 1999, : 742 - 743