Towards 50 years of platelet function analyser (PFA) testing

被引:11
|
作者
Favaloro, Emmanuel J. [1 ,2 ,3 ]
Pasalic, Leonardo [1 ,2 ,4 ]
Lippi, Giuseppe [5 ,6 ]
机构
[1] NSW Hlth Pathol, Inst Clin Pathol & Med Res ICPMR, Haematol, Westmead, NSW 2145, Australia
[2] Sydney Ctr Thrombosis & Haemostasis, Westmead, NSW, Australia
[3] Charles Sturt Univ, Fac Sci & Hlth, Wagga Wagga, NSW, Australia
[4] Univ Sydney, Westmead Clin Sch, Westmead, NSW, Australia
[5] Univ Verona, Sect Clin Biochem, Verona, Italy
[6] Univ Verona, Sch Med, Verona, Italy
关键词
in vitro bleeding time; PFA-100; PFA-200; platelet function analyser; LIGHT TRANSMITTANCE AGGREGOMETRY; VON-WILLEBRAND-DISORDER; BLEEDING-TIME PFA-100; ABO BLOOD-GROUP; IN-VITRO; LABORATORY DIAGNOSIS; CLINICAL UTILITY; CLOSURE TIMES; COAGULATION; PARAMETERS;
D O I
10.1515/cclm-2022-0666
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The platelet function analyser (PFA) is a prevalent platelet function screening instrument, and comes in two models-the original PFA-100 and the contemporary PFA-200. The instruments have 'identical' output, being a 'closure time' (CT). Moreover, normal reference ranges provided by the manufacturer, for the specific test cartridges, are the same for both models. There are three different types of test cartridge: collagen/epinephrine (C/Epi), collagen/adenosine diphosphate (C/ADP), and "Innovance PFA P2Y" (only available in certain geographical locations). The PFA-100 was released in the mid 1990s, and so is approaching 50 years of age. The PFA-200, released in some locations in the mid 2010s, is destined to eventually replace the PFA-100, but is not yet available in the USA. The test system is highly sensitive to von Willebrand disease (VWD; C/Epi and C/ADP) and to aspirin therapy (C/Epi only), but only has moderate sensitivity to defects in platelet function and/or deficiencies in platelet number. Accordingly, recommendations for use for screening platelet function vary according to user experience. Some workers have alternatively used the PFA to assess thrombosis risk or pre-operative bleeding risk. In this review, we provide an overview of the history of PFA, and summarise its current clinical utility.
引用
收藏
页码:851 / 860
页数:10
相关论文
共 50 条
  • [31] Use of the platelet function analyser (PFA-100®) to quantify the effect of low dose aspirin in patients with ischaemic heart disease
    Coakley, M
    Self, R
    Marchant, W
    Mackie, I
    Mallett, SV
    Mythen, M
    ANAESTHESIA, 2005, 60 (12) : 1173 - 1178
  • [32] Platelet function in preeclampsia: Platelet function analyzer (PFA-100) vs TEG
    Davies, J
    Fernando, R
    Hallworth, S
    ANESTHESIOLOGY, 2001, 94 (1A)
  • [33] Usage and utility of PFA-100 and cone NAD platelet analyzer impact-R for testing platelet function
    Postula, Marek
    Serafin, Agnieszka
    Marchel, Michal
    Filipiak, Krzysztof
    Tarchalska, Bozena
    Opolski, Grzegorz
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2007, 42 : S234 - S234
  • [34] Evaluation of platelet function on cord blood in 80 healthy term neonates using the Platelet Function Analyser (PFA-100): shorter in vitro bleeding times in neonates than adults
    Michael Boudewijns
    Marc Raes
    Veerle Peeters
    Alex Mewis
    Reinoud Cartuyvels
    Koen Magerman
    Jean-Luc Rummens
    European Journal of Pediatrics, 2003, 162 : 212 - 213
  • [35] Evaluation of platelet function in the parturient using the platelet function analyzer (PFA-100®).
    Nair, A
    Arnold, I
    Goolie-Scindain, J
    Bodian, CA
    Hossain, S
    Beilin, Y
    ANESTHESIOLOGY, 2001, 94 (1A) : U30 - U30
  • [36] Evaluation of platelet function on cord blood in 80 healthy term neonates using the Platelet Function Analyser (PFA-100): shorter in vitro bleeding times in neonates than adults
    Boudewijns, M
    Raes, M
    Peeters, V
    Mewis, A
    Cartuyvels, R
    Magerman, K
    Rummens, JL
    EUROPEAN JOURNAL OF PEDIATRICS, 2003, 162 (03) : 212 - 213
  • [37] Platelet function analyzer (PFA)-100® closure time in the evaluation of platelet disorders and platelet function:: a rebuttal
    Kratzer, M. A. A.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (08) : 1845 - 1846
  • [38] More on:: platelet function analyzer (PFA)-100® closure time in the evaluation of platelet disorders and platelet function
    Koscielny, J
    Kiesewetter, H
    Von Tempelhoff, GF
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (06) : 1426 - 1427
  • [39] Platelet function analyser-100 (PFA-100) monitoring does not predict bleeding after percutaneous kidney biopsy.
    Lboaya, Beriahili
    Islani, Nahid
    Lee, Frederick
    Miller, Eric
    Mire, Christopher
    Schmidt, Darren
    Fulop, Tibor
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2008, 51 (04) : A53 - A53
  • [40] Platelet function analyzer (PFA)-100® closure time in the evaluation of platelet disorders and platelet function -: a rebuttal
    Kratzer, M. A. A.
    Kretschmer, V.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (06) : 1429 - 1431