Towards 50 years of platelet function analyser (PFA) testing

被引:11
|
作者
Favaloro, Emmanuel J. [1 ,2 ,3 ]
Pasalic, Leonardo [1 ,2 ,4 ]
Lippi, Giuseppe [5 ,6 ]
机构
[1] NSW Hlth Pathol, Inst Clin Pathol & Med Res ICPMR, Haematol, Westmead, NSW 2145, Australia
[2] Sydney Ctr Thrombosis & Haemostasis, Westmead, NSW, Australia
[3] Charles Sturt Univ, Fac Sci & Hlth, Wagga Wagga, NSW, Australia
[4] Univ Sydney, Westmead Clin Sch, Westmead, NSW, Australia
[5] Univ Verona, Sect Clin Biochem, Verona, Italy
[6] Univ Verona, Sch Med, Verona, Italy
关键词
in vitro bleeding time; PFA-100; PFA-200; platelet function analyser; LIGHT TRANSMITTANCE AGGREGOMETRY; VON-WILLEBRAND-DISORDER; BLEEDING-TIME PFA-100; ABO BLOOD-GROUP; IN-VITRO; LABORATORY DIAGNOSIS; CLINICAL UTILITY; CLOSURE TIMES; COAGULATION; PARAMETERS;
D O I
10.1515/cclm-2022-0666
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The platelet function analyser (PFA) is a prevalent platelet function screening instrument, and comes in two models-the original PFA-100 and the contemporary PFA-200. The instruments have 'identical' output, being a 'closure time' (CT). Moreover, normal reference ranges provided by the manufacturer, for the specific test cartridges, are the same for both models. There are three different types of test cartridge: collagen/epinephrine (C/Epi), collagen/adenosine diphosphate (C/ADP), and "Innovance PFA P2Y" (only available in certain geographical locations). The PFA-100 was released in the mid 1990s, and so is approaching 50 years of age. The PFA-200, released in some locations in the mid 2010s, is destined to eventually replace the PFA-100, but is not yet available in the USA. The test system is highly sensitive to von Willebrand disease (VWD; C/Epi and C/ADP) and to aspirin therapy (C/Epi only), but only has moderate sensitivity to defects in platelet function and/or deficiencies in platelet number. Accordingly, recommendations for use for screening platelet function vary according to user experience. Some workers have alternatively used the PFA to assess thrombosis risk or pre-operative bleeding risk. In this review, we provide an overview of the history of PFA, and summarise its current clinical utility.
引用
收藏
页码:851 / 860
页数:10
相关论文
共 50 条
  • [21] Does the platelet function analyser (PFA-100®) predict blood loss after cardiopulmonary bypass?
    Fattorutto, M
    Pradier, O
    Schmartz, D
    Ickx, B
    Barvais, L
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (05) : 692 - 693
  • [22] The usefulness of the platelet function analyser (PFA-100) in screening for underlying bleeding disorders in women with menorrhagia
    Acharya, S.
    Barraclough, J.
    Ibrahim, M. S.
    Oxby, C.
    Jones, S. E.
    Parapia, L.
    O'Donovan, P.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2008, 28 (03) : 310 - 314
  • [23] In vitro monitoring of abciximab (Reopro) using thrombelastography (TEG) and the platelet function analyser (PFA-100).
    Antonio, AC
    Sukhu, K
    Keeling, DM
    Giangrande, PL
    Martin, PG
    BLOOD, 1999, 94 (10) : 63B - 63B
  • [24] Platelet function analyser-100 testing and primary haemostasis analysis
    Elalamy, I
    Hatmi, M
    BRITISH JOURNAL OF HAEMATOLOGY, 2006, 132 (06) : 796 - 797
  • [25] Preclinical studies for the use of the platelet function analyser PFA-100 (collagen/ADP cartridge) in dogs.
    Mischke, R
    Keidel, A
    DEUTSCHE TIERARZTLICHE WOCHENSCHRIFT, 2002, 109 (05): : 235 - 238
  • [26] Description of an In Vitro Platelet Function Analyzer (PFA-100/PFA-200) 30 Years in the Making
    Favaloro, Emmanuel J.
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2024, 50 (02): : 320 - 324
  • [27] Platelet activation can occur by shear stress alone in the PFA-100 platelet analyser
    Dunkley, S
    Harrison, P
    PLATELETS, 2005, 16 (02) : 81 - 84
  • [28] Evaluation of the effect of ketoprofen and carprofen on platelet function in dogs studied by pfa-100 point-of-care analyser
    Gaal, T.
    Halmay, Dora
    Kocsis, R.
    Abonyi-Toth, Zs.
    ACTA VETERINARIA HUNGARICA, 2007, 55 (03) : 287 - 294
  • [29] Utility of platelet function analyzer (PFA) in patients with suspected platelet function disorders
    Kaufmann, Jonas
    Adler, Marcel
    Nagler, Michael
    SWISS MEDICAL WEEKLY, 2018, 148 : 29S - 30S
  • [30] Platelet function analyzer (PFA)-100® closure time in the evaluation of platelet disorders and platelet function
    Hayward, CPM
    Harrison, P
    Cattaneo, M
    Ortel, TL
    Rao, AK
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (02) : 312 - 319