Optimised quality control method for determination of the radiochemical purity of [99mTc]Tc-mebrofenin and [99mTc]Tc-etifenin in a clinical context

被引:1
|
作者
Pirot, Charlotte [1 ,2 ,4 ]
Peyronnet, Damien [1 ,2 ]
Vigne, Jonathan [1 ,2 ,3 ]
机构
[1] UNICAEN, Dept Nucl Med, Caen, France
[2] UNICAEN, Dept Pharm, Caen, France
[3] Normandie Univ, Inst Blood & Brain Caen Normandie, Ctr Cyceron, UNICAEN,INSERM U1237,PhIND, F-14000 Caen, France
[4] UNICAEN, Dept Nucl Med, F-14032 Caen, France
关键词
quality control; practice guideline; nuclear medicine; pharmacy service; hospital; pharmaceutical preparations;
D O I
10.1136/ejhpharm-2022-003512
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
ObjectivesIn the context of a supply disruption of mebrofenin (Cholediam)-based kits for radiolabelling with technetium-99m [Tc-99m], the medicine agencies allowed the importation of a back-up radiopharmaceutical diagnostic agent, etifenin (Techida), to ensure continuous management of patients with hepatobiliary disorders in nuclear medicine departments. There are still issues regarding the measurement of radiochemical purity (RCP) with these kits based on the European Pharmacopoeia and the Summary of Product Characteristics (SPC). This study aims to identify and to optimise, in a clinical context, the most suitable thin layer chromatography (TLC) method for the determination of the RCP in terms of speed of response and reliability for [Tc-99m]Tc-mebrofenin and [Tc-99m]Tc-etifenin. Methods[Tc-99m]Tc-etifenin (n=4) and [Tc-99m]Tc-mebrofenin (n=5) were individually controlled using six different TLC methods and one high-performance liquid chromatography (HPLC) method for impurity identification ([Tc-99m](TcO2)(n) and Na[Tc-99m]TcO4), RCP (%) and duration of analysis (min). Two TLC methods were selected according to the recommendations of the Pharmacopoeia and SPC, two others were exactly the same but with a heating step, and the other two corresponded to a mix between the methods of the SPC and the Pharmacopoeia that were chosen to optimise RCP determination parameters. ResultsRadio-HPLC analysis allowed effective separation of [Tc-99m]Tc-etifenin and [Tc-99m]Tc-mebrofenin with a retention time of 8.05 +/- 0.02 min and 8.94 +/- 0.07 min, respectively, from Na[Tc-99m]TcO4 (retention time 2.76 +/- 0.03 min). HPLC showed an absence of Na[Tc-99m]TcO4 for [Tc-99m]Tc-mebrofenin and 0.2% for [Tc-99m]Tc-etifenin. Among the TLC methods, we identified the most suitable method which ensures the most compliant RCP (98.3 +/- 0.9%) in a time of 31.5 +/- 1.1 min. Also, it allowed a time saving of 15 min compared with the methods proposed by the Pharmacopoeia and the SPCs. ConclusionWe propose a TLC method that accelerates quality control by an average of 15 min while guaranteeing a reliable RCP.
引用
收藏
页码:376 / 380
页数:5
相关论文
共 50 条
  • [1] Validation of an alternative two-strip method for the quality control of [99mTc]Tc-ETIFENIN (TECHIDA®)
    Deschavannes, Arnaud
    Piquemal, Marie
    Rioufol, Catherine
    Clotagatide, Anthony
    APPLIED RADIATION AND ISOTOPES, 2025, 217
  • [2] Effect of 99Tc on the radiochemical purity of 99mTc radiopharmaceuticals
    Waight, Lynn A.
    Cunnane, Caroline M.
    O'Brien, Lesley M.
    Millar, Alistair M.
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (08) : 752 - 756
  • [3] Validation of an alternative radiochemical purity method for [99mTc]pentetate ([99mTc]DTPA)
    Candela Borre, Maria
    Tesan, Fiorella C.
    Leonardi, Natalia M.
    Zubillaga, Marcela B.
    Jimena Salgueiro, M.
    APPLIED RADIATION AND ISOTOPES, 2013, 82 : 322 - 324
  • [4] A Specific Method for the Determination of the Radiochemical Purity of [99mTc]DMSA Preparations
    Shales, Jonathan
    Brain, James
    Grigg, Julian
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2017, 60 : S311 - S311
  • [5] Dynamic [99mTc]Tc-mebrofenin SPECT/CT in preoperative planning of liver resection: a prospective study
    Bakos, Annamaria
    Libor, Laszlo
    Urban, Szabolcs
    Geczi, Tibor
    Bukva, Matyas
    Hohn, Jozsef
    Lazar, Gyoergy
    Nagy, Andras
    Farkas, Istvan
    Sipka, Gabor
    Pavics, Laszlo
    Besenyi, Zsuzsanna
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [6] Visualization of a pyelocaliceal diverticulum with [99mTc]Tc-DTPA and [99mTc]Tc-DMSA scintigraphy
    Ibisoglu, E. Orsal
    Uslu, H.
    Tatoglu, M. Tarik
    Gungor, S.
    Haksal, C.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2020, 39 (05): : 325 - 326
  • [7] [99mTc]Tc[99mTc]Tc-DMSA scanning in children: well beyond urinary tract infections
    Biassoni, Lorenzo
    Heath, Gemma
    Morris, Elizabeth
    Sizer, Natalie
    Rooney, Georgina
    Morrall, Emily
    Kromidias, Costas
    Ben Thurlow
    Easty, Marina
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [8] Treatment of [99mTc]Tc-hydroxy-diphosphonate ([99mTc]Tc-HDP) extravasation using hyaluronidase
    Doornhof, Kevin R.
    de Lussanet de la Sabloniere, Quido
    Koolen, Stijn L. W.
    Konijnenberg, Mark W.
    PHARMACOLOGY RESEARCH & PERSPECTIVES, 2024, 12 (04):
  • [9] Radiochemical purity of 99mTc radio-pharmaceuticals
    Vucina, J. L.
    Vuga, D. A.
    Vukicevic-Nikolic, N. S.
    Journal of Radioanalytical and Nuclear Chemistry, 1995, 199 (02)
  • [10] Radiochemical purity and stability of generic 99mTc Tetrofosmin
    Albarnawi, Emam
    Zimmer, Mike
    Voll, Bruce
    Riehle, Lisa
    Spies, Stewart
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53