Optimised quality control method for determination of the radiochemical purity of [99mTc]Tc-mebrofenin and [99mTc]Tc-etifenin in a clinical context

被引:1
|
作者
Pirot, Charlotte [1 ,2 ,4 ]
Peyronnet, Damien [1 ,2 ]
Vigne, Jonathan [1 ,2 ,3 ]
机构
[1] UNICAEN, Dept Nucl Med, Caen, France
[2] UNICAEN, Dept Pharm, Caen, France
[3] Normandie Univ, Inst Blood & Brain Caen Normandie, Ctr Cyceron, UNICAEN,INSERM U1237,PhIND, F-14000 Caen, France
[4] UNICAEN, Dept Nucl Med, F-14032 Caen, France
关键词
quality control; practice guideline; nuclear medicine; pharmacy service; hospital; pharmaceutical preparations;
D O I
10.1136/ejhpharm-2022-003512
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
ObjectivesIn the context of a supply disruption of mebrofenin (Cholediam)-based kits for radiolabelling with technetium-99m [Tc-99m], the medicine agencies allowed the importation of a back-up radiopharmaceutical diagnostic agent, etifenin (Techida), to ensure continuous management of patients with hepatobiliary disorders in nuclear medicine departments. There are still issues regarding the measurement of radiochemical purity (RCP) with these kits based on the European Pharmacopoeia and the Summary of Product Characteristics (SPC). This study aims to identify and to optimise, in a clinical context, the most suitable thin layer chromatography (TLC) method for the determination of the RCP in terms of speed of response and reliability for [Tc-99m]Tc-mebrofenin and [Tc-99m]Tc-etifenin. Methods[Tc-99m]Tc-etifenin (n=4) and [Tc-99m]Tc-mebrofenin (n=5) were individually controlled using six different TLC methods and one high-performance liquid chromatography (HPLC) method for impurity identification ([Tc-99m](TcO2)(n) and Na[Tc-99m]TcO4), RCP (%) and duration of analysis (min). Two TLC methods were selected according to the recommendations of the Pharmacopoeia and SPC, two others were exactly the same but with a heating step, and the other two corresponded to a mix between the methods of the SPC and the Pharmacopoeia that were chosen to optimise RCP determination parameters. ResultsRadio-HPLC analysis allowed effective separation of [Tc-99m]Tc-etifenin and [Tc-99m]Tc-mebrofenin with a retention time of 8.05 +/- 0.02 min and 8.94 +/- 0.07 min, respectively, from Na[Tc-99m]TcO4 (retention time 2.76 +/- 0.03 min). HPLC showed an absence of Na[Tc-99m]TcO4 for [Tc-99m]Tc-mebrofenin and 0.2% for [Tc-99m]Tc-etifenin. Among the TLC methods, we identified the most suitable method which ensures the most compliant RCP (98.3 +/- 0.9%) in a time of 31.5 +/- 1.1 min. Also, it allowed a time saving of 15 min compared with the methods proposed by the Pharmacopoeia and the SPCs. ConclusionWe propose a TLC method that accelerates quality control by an average of 15 min while guaranteeing a reliable RCP.
引用
收藏
页码:376 / 380
页数:5
相关论文
共 50 条
  • [41] Transferability of a two-strip method for the quality control of technetium-99m mercaptoacetyltriglycine ([99mTc]Tc-MAG3)
    Tessaire, Thomas
    De Neef, Lea
    Cailly, Thomas
    Peyronnet, Damien
    Vigne, Jonathan
    EUROPEAN JOURNAL OF HOSPITAL PHARMACY, 2023, 30 (03) : 167 - 171
  • [42] Optimizing the Assessment of [99mTc]-SestaMIBI Radiochemical Purity: A Study on Stability in Syringe Storage
    Hashemizadeh, Haleh
    Hassanzadeh, Leila
    Azizian, Homa
    Paydar, Reza
    Ahmadvand, Davoud
    IRANIAN HEART JOURNAL, 2025, 26 (01): : 67 - 80
  • [43] Quantitative Assessment of Liver Impairment in Chronic Viral Hepatitis with [99mTc]Tc-Mebrofenin: A Noninvasive Attempt to Stage Viral Hepatitis-Associated Liver Fibrosis
    Jocius, Donatas
    Vajauskas, Donatas
    Mikelis, Kipras
    Jokubauskiene, Skirmante
    Jakutiene, Jolita
    Strupas, Kestutis
    Tamosiunas, Algirdas E.
    MEDICINA-LITHUANIA, 2022, 58 (10):
  • [44] A quality-control test for the radionuclidic purity of cyclotron-produced 99mTc
    Tanguay, Jesse
    Hou, Xinchi
    Celler, Anna
    Benard, Francois
    Schaffer, Paul
    Buckley, Ken
    Ruth, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [45] Diagnostic Accuracy of [99mTc]Tc-Sestamibi in the Assessment of Thyroid Nodules
    Yordanova, A.
    Mahjoob, S.
    Lingohr, P.
    Turler, A.
    Palmedo, H.
    Biersack, H.
    Kristiansen, G.
    Essler, M.
    Ahmadzadehfar, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S650 - S650
  • [46] Imaging Hydrogen Sulfide in Hypoxic Tissue with [99mTc]Tc-Gluconate
    Kweon, Yongkyoung
    Park, Ji-Yong
    Kim, Young-Joo
    Lee, Yun-Sang
    Jeong, Jae-Min
    MOLECULES, 2021, 26 (01):
  • [47] Diagnostic accuracy of [99mTc]Tc-Sestamibi in the assessment of thyroid nodules
    Yordanova, Anna
    Mahjoob, Soha
    Lingohr, Philipp
    Kalff, Joerg
    Tuerler, Andreas
    Palmedo, Holger
    Biersack, Hans-Juergen
    Kristiansen, Glen
    Farahati, Jamshid
    Essler, Markus
    Ahmadzadehfar, Hojjat
    ONCOTARGET, 2017, 8 (55) : 94681 - 94691
  • [48] Joint EANM/SNMMI/IHPBA procedure guideline for [99mTc]Tc-mebrofenin hepatobiliary scintigraphy SPECT/CT in the quantitative assessment of the future liver remnant function
    Arntz, Pieter J. W.
    Deroose, Christophe M.
    Marcus, Charles
    Sturesson, Christian
    Panaro, Fabrizio
    Erdmann, Joris
    Manevska, Nevena
    Moadel, Renee
    de Geus-Oei, Lioe-Fee
    Bennink, Roel J.
    HPB, 2023, 25 (10) : 1131 - 1144
  • [49] Acute cholecystitis - an isolated unusual presentation of thrombotic microangiopathy of gall bladder due to antiphospholipid syndrome with lupus positivity detected by [99mTc]Tc-mebrofenin scan
    Padma, Subramanyam
    Sundaram, Palaniswamy Shanmuga
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2022, 30 (02): : 136 - 139
  • [50] Using Clinical and Imaging Data to Forecast [99mTc]Tc-DMSA Scan Findings
    Paiva, S.
    Costa, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S51 - S51