Brain Parcellation Repeatability and Reproducibility Using Conventional and Quantitative 3D MR Imaging

被引:1
|
作者
Warntjes, J. B. M. [1 ,4 ,5 ]
Lundberg, P. [2 ,3 ]
Tisell, A. [2 ,3 ]
机构
[1] Linkoping Univ, Ctr Med Image Sci & Visualizat, Linkoping, Sweden
[2] Linkoping Univ, Dept Radiat Phys, Linkoping, Sweden
[3] Linkoping Univ, Dept Hlth Med & Caring Sci, Linkoping, Sweden
[4] SyntheticMR, Linkoping, Sweden
[5] Linkoping Univ Hosp, Ctr Med Imaging Sci & Visualisat, S-58185 Linkoping, Sweden
关键词
VOLUMETRY; 3D-QALAS; SOFTWARE;
D O I
10.3174/ajnr.A7937
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Automatic brain parcellation is typically performed on dedicated MR imaging sequences, which require valuable examination time. In this study, a 3D MR imaging quantification sequence to retrieve R-1 and R-2 relaxation rates and proton density maps was used to synthesize a T1-weighted image stack for brain volume measurement, thereby combining image data for multiple purposes. The repeatability and reproducibility of using the conventional and synthetic input data were evaluated.MATERIALS AND METHODS: Twelve subjects with a mean age of 54?years were scanned twice at 1.5T and 3T with 3D-QALAS and a conventionally acquired T1-weighted sequence. Using SyMRI, we converted the R-1, R-2, and proton density maps into synthetic T1-weighted images. Both the conventional T1-weighted and the synthetic 3D-T1-weighted inversion recovery images were processed for brain parcellation by NeuroQuant. Bland-Altman statistics were used to correlate the volumes of 12 brain structures. The coefficient of variation was used to evaluate the repeatability.RESULTS: A high correlation with medians of 0.97 for 1.5T and 0.92 for 3T was found. A high repeatability was shown with a median coefficient of variation of 1.2% for both T1-weighted and synthetic 3D-T1-weighted inversion recovery at 1.5T, and 1.5% for T1-weighted imaging and 4.4% for synthetic 3D-T1-weighted inversion recovery at 3T. However, significant biases were observed between the methods and field strengths.CONCLUSIONS: It is possible to perform MR imaging quantification of R-1, R-2, and proton density maps to synthesize a 3D-T1-weighted image stack, which can be used for automatic brain parcellation. Synthetic parameter settings should be reinvestigated to reduce the observed bias.
引用
收藏
页码:910 / 915
页数:6
相关论文
共 50 条
  • [41] 3D analysis of the peritalar complex using MR imaging in live patients
    Stindel, E
    Udupa, JK
    Hirsch, BE
    Odhner, D
    MEDICAL IMAGING 1999: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1999, 3660 : 500 - 511
  • [42] Assessment of metabolite quantitation reproducibility in serial 3D-1H-MR spectroscopic Imaging of human brain using sterelotactic repositioning
    Langer, Deanna L.
    Rakaric, Peter
    Kirilova, Anna
    Jaffray, David A.
    Damyanovich, Andrei Z.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (04) : 666 - 673
  • [43] Repeatability of Quantitative Imaging on the MR-Linac for Treatment Response Monitoring
    Kooreman, E. S.
    Van Houdt, P. J.
    Nowee, M. E.
    Van Pelt, V.
    Koetsveld, F.
    Ter Beek, L. C.
    Peeters, J. M.
    Van der Heide, U. A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S537 - S538
  • [44] QUANTITATIVE 3D IMAGING - SAMPLING EFFECTS
    POUSSE, A
    BENYOUNES, R
    MAS, J
    BIDET, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (08): : 642 - 642
  • [45] On the Compactness, Efficiency, and Representation of 3D Convolutional Networks: Brain Parcellation as a Pretext Task
    Li, Wenqi
    Wang, Guotai
    Fidon, Lucas
    Ourselin, Sebastien
    Cardoso, M. Jorge
    Vercauteren, Tom
    INFORMATION PROCESSING IN MEDICAL IMAGING (IPMI 2017), 2017, 10265 : 348 - 360
  • [46] Surgical treatment of Parkinson's disease using 3D MR stereotactic imaging and chronic deep brain stimulation
    Cornu, P
    Dormont, D
    Damier, P
    Pidoux, B
    Bonnet, AM
    Philippon, J
    Agid, Y
    Marsault, C
    NEUROLOGY, 1997, 48 (03) : 4104 - 4104
  • [47] 3D MR imaging of coronary arteriovenous fistulas
    Duerinckx, AJ
    Shaaban, A
    Lewis, A
    Perloff, J
    Laks, H
    EUROPEAN RADIOLOGY, 2000, 10 (09) : 1459 - 1463
  • [48] Fast 3D cardiac cine MR imaging
    Alley, MT
    Napel, S
    Amano, Y
    Paik, DS
    Shifrin, RY
    Shimakawa, A
    Pelc, NJ
    Herfkens, RJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (05): : 751 - 755
  • [49] 3D MR imaging in real-time
    Guttman, MA
    McVeigh, ER
    MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 : 394 - 400
  • [50] 3D MR imaging of coronary arteriovenous fistulas
    A. J. Duerinckx
    A. Shaaban
    A. Lewis
    J. Perloff
    H. Laks
    European Radiology, 2000, 10 : 1459 - 1463