Brain Parcellation Repeatability and Reproducibility Using Conventional and Quantitative 3D MR Imaging

被引:1
|
作者
Warntjes, J. B. M. [1 ,4 ,5 ]
Lundberg, P. [2 ,3 ]
Tisell, A. [2 ,3 ]
机构
[1] Linkoping Univ, Ctr Med Image Sci & Visualizat, Linkoping, Sweden
[2] Linkoping Univ, Dept Radiat Phys, Linkoping, Sweden
[3] Linkoping Univ, Dept Hlth Med & Caring Sci, Linkoping, Sweden
[4] SyntheticMR, Linkoping, Sweden
[5] Linkoping Univ Hosp, Ctr Med Imaging Sci & Visualisat, S-58185 Linkoping, Sweden
关键词
VOLUMETRY; 3D-QALAS; SOFTWARE;
D O I
10.3174/ajnr.A7937
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Automatic brain parcellation is typically performed on dedicated MR imaging sequences, which require valuable examination time. In this study, a 3D MR imaging quantification sequence to retrieve R-1 and R-2 relaxation rates and proton density maps was used to synthesize a T1-weighted image stack for brain volume measurement, thereby combining image data for multiple purposes. The repeatability and reproducibility of using the conventional and synthetic input data were evaluated.MATERIALS AND METHODS: Twelve subjects with a mean age of 54?years were scanned twice at 1.5T and 3T with 3D-QALAS and a conventionally acquired T1-weighted sequence. Using SyMRI, we converted the R-1, R-2, and proton density maps into synthetic T1-weighted images. Both the conventional T1-weighted and the synthetic 3D-T1-weighted inversion recovery images were processed for brain parcellation by NeuroQuant. Bland-Altman statistics were used to correlate the volumes of 12 brain structures. The coefficient of variation was used to evaluate the repeatability.RESULTS: A high correlation with medians of 0.97 for 1.5T and 0.92 for 3T was found. A high repeatability was shown with a median coefficient of variation of 1.2% for both T1-weighted and synthetic 3D-T1-weighted inversion recovery at 1.5T, and 1.5% for T1-weighted imaging and 4.4% for synthetic 3D-T1-weighted inversion recovery at 3T. However, significant biases were observed between the methods and field strengths.CONCLUSIONS: It is possible to perform MR imaging quantification of R-1, R-2, and proton density maps to synthesize a 3D-T1-weighted image stack, which can be used for automatic brain parcellation. Synthetic parameter settings should be reinvestigated to reduce the observed bias.
引用
收藏
页码:910 / 915
页数:6
相关论文
共 50 条
  • [1] Quantitative Evaluation of Repeatability and Reproducibility of MR Fingerprinting and Conventional Contrast-Weighted MRI for Human Brain Radiomics
    Zhu, T.
    Lu, L.
    Chen, Y.
    Lian, J.
    Shen, C.
    Fried, D.
    Szalkowski, G.
    Oakey, M.
    Das, S.
    Marks, L.
    Lin, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E355 - E355
  • [2] Repeatability and reproducibility of 3D MR fingerprinting relaxometry measurements in normal breast tissue
    Panda, Ananya
    Chen, Yong
    Ropella-Panagis, Kathleen
    Ghodasara, Satyam
    Stopchinski, Marcie
    Seyfried, Nicole
    Wright, Katherine
    Seiberlich, Nicole
    Griswold, Mark
    Gulani, Vikas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (04) : 1133 - 1143
  • [3] Reproducibility and Repeatability of MR Fingerprinting Relaxometry in the Human Brain
    Koerzdoerfer, Gregor
    Kirsch, Rainer
    Liu, Kecheng
    Pfeuffer, Josef
    Hensel, Bernhard
    Jiang, Yun
    Ma, Dan
    Gratz, Marcel
    Baer, Peter
    Bogner, Wolfgang
    Springer, Elisabeth
    Cardoso, Pedro Lima
    Umutlu, Lale
    Trattnig, Siegfried
    Griswold, Mark
    Gulani, Vikas
    Nittka, Mathias
    RADIOLOGY, 2019, 292 (02) : 429 - 437
  • [4] Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System
    Lassen, Martin L.
    Muzik, Otto
    Beyer, Thomas
    Hacker, Marcus
    Ladefoged, Claes Nohr
    Cal-Gonzalez, Jacobo
    Wadsak, Wolfgang
    Rausch, Ivo
    Langer, Oliver
    Bauer, Martin
    FRONTIERS IN NEUROSCIENCE, 2017, 11
  • [5] Statistical considerations for repeatability and reproducibility of quantitative imaging biomarkers
    Ye, Shangyuan
    Lim, Jeong Youn
    Huang, Wei
    BJR OPEN, 2022, 4 (01):
  • [6] Repeatability and variation of region-of-interest methods using quantitative diffusion tensor MR imaging of the brain
    Ullamari Hakulinen
    Antti Brander
    Pertti Ryymin
    Juha Öhman
    Seppo Soimakallio
    Mika Helminen
    Prasun Dastidar
    Hannu Eskola
    BMC Medical Imaging, 12
  • [7] Repeatability and variation of region-of-interest methods using quantitative diffusion tensor MR imaging of the brain
    Hakulinen, Ullamari
    Brander, Antti
    Ryymin, Pertti
    Ohman, Juha
    Soimakallio, Seppo
    Helminen, Mika
    Dastidar, Prasun
    Eskola, Hannu
    BMC MEDICAL IMAGING, 2012, 12
  • [8] Coarctation of the aorta: comparison of aortic dimensions between conventional MR imaging, 3D MR angiography, and conventional angiography
    Godart, F
    Labrot, G
    Devos, P
    McFadden, E
    Rey, C
    Beregi, JP
    EUROPEAN RADIOLOGY, 2002, 12 (08) : 2034 - 2039
  • [9] Coarctation of the aorta: comparison of aortic dimensions between conventional MR imaging, 3D MR angiography, and conventional angiography
    François Godart
    Gabrielle Labrot
    Patrick Devos
    Eugène McFadden
    Christian Rey
    Jean-Paul Beregi
    European Radiology, 2002, 12 : 2034 - 2039
  • [10] 3D chemical imaging of the brain using quantitative IR spectro-microscopy
    Ogunleke, Abiodun
    Recur, Benoit
    Balacey, Hugo
    Chen, Hsiang-Hsin
    Delugin, Maylis
    Hwu, Yeukuang
    Javerzat, Sophie
    Petibois, Cyril
    CHEMICAL SCIENCE, 2018, 9 (01) : 189 - 198