?Image quality evaluation of the Precise image CT deep learning reconstruction algorithm compared to Filtered Back-projection and iDose4: a phantom study at different dose levels?

被引:4
|
作者
Barca, Patrizio [1 ,4 ]
Domenichelli, Sara [1 ]
Golfieri, Rita [3 ]
Pierotti, Luisa [1 ]
Spagnoli, Lorenzo [1 ,2 ]
Tomasi, Silvia [1 ,2 ]
Strigari, Lidia [1 ]
机构
[1] Univ Bologna, Dept Med Phys, IRCCS Azienda Osped, Bologna, Italy
[2] Univ Bologna, Med Phys Specializat Sch, Alma Master Studiorium, Bologna, Italy
[3] Univ Bologna, Radiol Addomino Pelv Diagnost & Interventist, IRCCS Azienda Osped, Bologna, Italy
[4] Univ Bologna, IRCCS Azienda Osped, Bologna, Italy
关键词
Deep learning CT image reconstruction; Philips Precise Image; Image quality; Abdominal protocol; STATISTICAL ITERATIVE RECONSTRUCTION; NOISE-POWER SPECTRUM; ABDOMINAL CT; COMPUTED-TOMOGRAPHY; CHEST CT; REDUCTION; OPTIMIZATION; PERFORMANCE; STANDARD; SYSTEM;
D O I
10.1016/j.ejmp.2022.102517
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To characterize the performance of the Precise Image (PI) deep learning reconstruction (DLR) algorithm for abdominal Computed Tomography (CT) imaging.Methods: CT images of the Catphan-600 phantom (equipped with an external annulus) were acquired using an abdominal protocol at four dose levels and reconstructed using FBP, iDose4 (levels 2,5) and PI ('Soft Tissue' definition, levels 'Sharper','Sharp','Standard','Smooth','Smoother'). Image noise, image non-uniformity, noise power spectrum (NPS), target transfer function (TTF), detectability index (d'), CT numbers accuracy and image histograms were analyzed.Results: The behavior of the PI algorithm depended strongly on the selected level of reconstruction. The phantom analysis suggested that the PI image noise decreased linearly by varying the level of reconstruction from Sharper to Smoother, expressing a noise reduction up to 80% with respect to FBP. Additionally, the non-uniformity decreased, the histograms became narrower, and d' values increased as PI reconstruction levels changed from Sharper to Smoother. PI had no significant impact on the average CT number of different contrast objects. The conventional FBP NPS was deeply altered only by Smooth and Smoother levels of reconstruction. Furthermore, spatial resolution was found to be dose-and contrast-dependent, but in each analyzed condition it was greater than or comparable to FBP and iDose4 TTFs.Conclusions: The PI algorithm can reduce image noise with respect to FBP and iDose4; spatial resolution, CT numbers and image uniformity are generally preserved by the algorithm but changes in NPS for the Smooth and Smoother levels need to be considered in protocols implementation.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels
    Love, A.
    Olsson, M-L
    Siemund, R.
    Stalhammar, F.
    Bjorkman-Burtscher, I. M.
    Soderberg, M.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1031):
  • [32] Dose reduction and image quality in CT examinations using an iterative reconstruction algorithm: a phantom study
    Guariglia, S.
    Meliado, G.
    Zivelonghi, E.
    Pinali, L.
    Montemezzi, S.
    Cavedon, C.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (04):
  • [33] Superior objective and subjective image quality of deep learning reconstruction for low-dose abdominal CT imaging in comparison with model-based iterative reconstruction and filtered back projection
    Tamura, Akio
    Mukaida, Eisuke
    Ota, Yoshitaka
    Kamata, Masayoshi
    Abe, Shun
    Yoshioka, Kunihiro
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1123):
  • [34] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Damiano Caruso
    Domenico De Santis
    Antonella Del Gaudio
    Gisella Guido
    Marta Zerunian
    Michela Polici
    Daniela Valanzuolo
    Dominga Pugliese
    Raffaello Persechino
    Antonio Cremona
    Luca Barbato
    Andrea Caloisi
    Elsa Iannicelli
    Andrea Laghi
    [J]. European Radiology, 2024, 34 : 2384 - 2393
  • [35] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Caruso, Damiano
    De Santis, Domenico
    Del Gaudio, Antonella
    Guido, Gisella
    Zerunian, Marta
    Polici, Michela
    Valanzuolo, Daniela
    Pugliese, Dominga
    Persechino, Raffaello
    Cremona, Antonio
    Barbato, Luca
    Caloisi, Andrea
    Iannicelli, Elsa
    Laghi, Andrea
    [J]. EUROPEAN RADIOLOGY, 2024, 34 (04) : 2384 - 2393
  • [36] The influence of a deep learning image reconstruction algorithm on the image quality and auto-analysis of pulmonary nodules at ultra-low dose chest CT: a phantom study
    Yao, Yue
    Guo, Baobin
    Li, Jianying
    Yang, Quanxin
    Li, Xiaohui
    Deng, Lei
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (05) : 2777 - 2791
  • [37] Adaptive Iterative Dose Reduction 3D Versus Filtered Back Projection in CT: Evaluation of Image Quality
    Joemai, Raoul M. S.
    Veldkamp, Wouter J. H.
    Kroft, Lucia J. M.
    Hernandez-Giron, Irene
    Geleijns, Jacob
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (06) : 1291 - 1297
  • [38] Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study
    Djamel Dabli
    Maeliss Loisy
    Julien Frandon
    Fabien de Oliveira
    Azhar Mohamad Meerun
    Boris Guiu
    Jean-Paul Beregi
    Joël Greffier
    [J]. European Radiology Experimental, 7
  • [39] Deep learning–based denoising algorithm in comparison to iterative reconstruction and filtered back projection: a 12-reader phantom study
    Youngjune Kim
    Dong Yul Oh
    Won Chang
    Eunhee Kang
    Jong Chul Ye
    Kyeorye Lee
    Hae Young Kim
    Young Hoon Kim
    Ji Hoon Park
    Yoon Jin Lee
    Kyoung Ho Lee
    [J]. European Radiology, 2021, 31 : 8755 - 8764
  • [40] Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study
    Dabli, Djamel
    Loisy, Maeliss
    Frandon, Julien
    de Oliveira, Fabien
    Meerun, Azhar Mohamad
    Guiu, Boris
    Beregi, Jean-Paul
    Greffier, Joel
    [J]. EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)