Selective determination of cuprous ion in copper dissolving solution based on bathocuproine-modified expanded graphite electrode

被引:0
|
作者
Chen, Xiaohui [1 ]
Sun, Yufa [2 ]
Wang, Wenchang [2 ]
Chen, Zhidong [2 ]
Ming, Zhiyao [3 ]
机构
[1] Changzhou Inst Technol, Sch Chem & Mat Engn, Changzhou 213032, Peoples R China
[2] Changzhou Univ, Sch Petrochem & Engn, Changzhou 213164, Peoples R China
[3] Jiangsu Mingfeng Elect Mat Technol Co Ltd, Changzhou 213341, Peoples R China
基金
中国国家自然科学基金;
关键词
Cuprous ions; Bathocuproine; Expanded graphite; Specific adsorption; Selective determination; ELECTROPLATING SOLUTION; CU(I); COMPLEXES; COMPOSITE; CHLORIDE; SENSOR; ACID;
D O I
10.1007/s44211-023-00358-w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The presence of cuprous ions in the copper-dissolving solution significantly affects the microstructure of copper plated surface. Fewer quantitative analyses of cuprous ions in the copper foil productive process had rarely been involved so far. In the present work, a novel electrochemical sensor of the bathocuproine (BCP) modified expanded graphite (EG) electrode was developed for the selective determination of cuprous ions. EG has a large surface area, good adsorption, and excellent electrochemical performance which remarkably promoted analytical sensitivity. Meanwhile, the selective determination of the BCP-EG electrode for cuprous ions in the coexistence of ten thousand times of copper ions have been achieved on the benefit of the special coordination of BCP to cuprous ions. In the coexistence of 50 g/L copper ions, the analytical performance of the BCP-EG electrode for the determination of cuprous ions had been examined. The results represented a wide detection range of cuprous ions in the range of 1.0 mu g/L-5.0 mg/L, with a low detection limit of 0.18 mu g/L (S/N = 3) and the BCP-EG electrode has great selectivity to cuprous ions in presence of various interferences. The analytical selectively for cuprous ions supported by the proposed electrode would be a potential analytical tool for quality improvement in electrolytic copper foil manufacturing.
引用
收藏
页码:1465 / 1473
页数:9
相关论文
共 50 条
  • [41] Voltammetric determination of fenitrothion based on pencil graphite electrode modified with poly(Purpald®)
    Soysal, Mert
    CHEMICAL PAPERS, 2019, 73 (07): : 1785 - 1794
  • [42] Electrochemical Sensor Based on a Modified Graphite Screen Printed Electrode for Amitriptyline Determination
    Nasab, Zoheira Bagheri
    Nejad, Fariba Garkani
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2022, 58 (01) : 100 - 108
  • [43] Amperometric determination of norepinephrine based on dual-film modified graphite electrode
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao, 5 Suppl (159):
  • [44] Voltammetric determination of fenitrothion based on pencil graphite electrode modified with poly(Purpald®)
    Mert Soysal
    Chemical Papers, 2019, 73 : 1785 - 1794
  • [45] Phosphate Ion-Selective Electrode Based on Electrochemically Modified Iron
    Fan, Ronghua
    Zhang, Xiwen
    Wu, Jie
    Zhang, Luwei
    Chen, Weiyun
    Yang, Qiaozhi
    Zheng, Rui
    Zhang, Lifeng
    Li, Xin
    Xu, Kebin
    ACS OMEGA, 2024, 9 (40): : 41217 - 41224
  • [46] Fabrication of a Phosphate Ion Selective Electrode Based on Modified Molybdenum Metal
    Xu, Kebin
    Kitazumi, Yuki
    Kano, Kenji
    Sasaki, Takayuki
    Shirai, Osamu
    ANALYTICAL SCIENCES, 2020, 36 (02) : 201 - 206
  • [47] Fabrication of a Phosphate Ion Selective Electrode Based on Modified Molybdenum Metal
    Kebin Xu
    Yuki Kitazumi
    Kenji Kano
    Takayuki Sasaki
    Osamu Shirai
    Analytical Sciences, 2020, 36 : 201 - 205
  • [48] Determination of isoniazid by a copper-based metal-organic frameworks/carbon nitride quantum dots modified pencil graphite electrode as a highly sensitive and selective sensor
    Pashazadeh, Sara
    Habibi, Biuck
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 876 (876)
  • [49] Nonenzymatic glucose sensor based on disposable pencil graphite electrode modified by copper nanoparticles
    Pourbeyram, Sima
    Mehdizadeh, Khadijeh
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2016, 24 (04) : 894 - 902
  • [50] Construction and performance characteristics of polymeric membrane electrode and coated graphite electrode for the selective determination of Fe3+ ion
    Bandi, Koteswara Rao
    Singh, Ashok K.
    Upadhyay, Anjali
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 36 : 187 - 193