Selective determination of cuprous ion in copper dissolving solution based on bathocuproine-modified expanded graphite electrode

被引:0
|
作者
Chen, Xiaohui [1 ]
Sun, Yufa [2 ]
Wang, Wenchang [2 ]
Chen, Zhidong [2 ]
Ming, Zhiyao [3 ]
机构
[1] Changzhou Inst Technol, Sch Chem & Mat Engn, Changzhou 213032, Peoples R China
[2] Changzhou Univ, Sch Petrochem & Engn, Changzhou 213164, Peoples R China
[3] Jiangsu Mingfeng Elect Mat Technol Co Ltd, Changzhou 213341, Peoples R China
基金
中国国家自然科学基金;
关键词
Cuprous ions; Bathocuproine; Expanded graphite; Specific adsorption; Selective determination; ELECTROPLATING SOLUTION; CU(I); COMPLEXES; COMPOSITE; CHLORIDE; SENSOR; ACID;
D O I
10.1007/s44211-023-00358-w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The presence of cuprous ions in the copper-dissolving solution significantly affects the microstructure of copper plated surface. Fewer quantitative analyses of cuprous ions in the copper foil productive process had rarely been involved so far. In the present work, a novel electrochemical sensor of the bathocuproine (BCP) modified expanded graphite (EG) electrode was developed for the selective determination of cuprous ions. EG has a large surface area, good adsorption, and excellent electrochemical performance which remarkably promoted analytical sensitivity. Meanwhile, the selective determination of the BCP-EG electrode for cuprous ions in the coexistence of ten thousand times of copper ions have been achieved on the benefit of the special coordination of BCP to cuprous ions. In the coexistence of 50 g/L copper ions, the analytical performance of the BCP-EG electrode for the determination of cuprous ions had been examined. The results represented a wide detection range of cuprous ions in the range of 1.0 mu g/L-5.0 mg/L, with a low detection limit of 0.18 mu g/L (S/N = 3) and the BCP-EG electrode has great selectivity to cuprous ions in presence of various interferences. The analytical selectively for cuprous ions supported by the proposed electrode would be a potential analytical tool for quality improvement in electrolytic copper foil manufacturing.
引用
收藏
页码:1465 / 1473
页数:9
相关论文
共 50 条
  • [21] POTENTIOMETRIC DETERMINATION OF COPPER IN PALM OIL WITH A COPPER(II) ION-SELECTIVE ELECTRODE
    FUNG, YS
    FUNG, KW
    ANALYST, 1978, 103 (1223) : 149 - 155
  • [22] A sensitive o-aminophenol sensor based on a modified montmorillonite-modified expanded graphite electrode
    Wang, Zhiliang
    Kong, Yong
    Yao, Chao
    Wang, Yu
    Ding, Xiufeng
    Zhou, Yongsheng
    APPLIED CLAY SCIENCE, 2012, 55 : 173 - 176
  • [23] DETERMINATION OF VANADIUM(V) IN SOLUTION BY A LIQUID ION-SELECTIVE ELECTRODE
    LUGININ, VA
    KOMOVA, VI
    GREKOVICH, AL
    PALNIKOVA, TI
    VESTNIK LENINGRADSKOGO UNIVERSITETA SERIYA FIZIKA KHIMIYA, 1987, (01): : 95 - 97
  • [24] VOLTAMMETRIC DETERMINATION OF SULFITE USING GRAPHITE PASTE ELECTRODE MODIFIED WITH NANOPARTICLES OF COPPER PENTACYANONITROSYLFERRATE
    Do Carmo, D. R.
    Silvestrini, D. R.
    Cumba, L. R.
    Souza, M. M.
    18 SIMPOSIO BRASILEIRO DE ELETROQUIMICA E ELETROANALITICA (XVIII SIBEE), 2012, 43 (01): : 217 - 224
  • [25] A Pencil Graphite Electrode In Situ Modified by Monovalent Copper: a Promising Tool for the Determination of Methylxanthines
    Navratil, Rudolf
    Jelen, Frantisek
    Kayran, Yasin Ugur
    Trnkova, Libuse
    ELECTROANALYSIS, 2014, 26 (05) : 952 - 961
  • [26] Highly Sensitive and Selective Determination of Dopamine Based on Graphite Nanosheet-Nafion Composite Film Modified Electrode
    Chen, Siming
    Yang, Wensheng
    Chen, Xu
    ELECTROANALYSIS, 2010, 22 (09) : 908 - 911
  • [27] Performance evaluation of copper ion selective electrode based on cyanocopolymers
    Gupta, KC
    D'Arc, MJ
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (03) : 171 - 176
  • [28] Electrochemical Determination of Copper(II) in Water Samples Using a Novel Ion-Selective Electrode Based on a Graphite Oxide-Imprinted Polymer Composite
    Topcu, Cihan
    Lacin, Gamze
    Yilmaz, Vedat
    Coldur, Fatih
    Caglar, Bulent
    Cubuk, Osman
    Isildak, Ibrahim
    ANALYTICAL LETTERS, 2018, 51 (12) : 1890 - 1910
  • [29] Application of Graphene/Tetraphenylboron-Dopamine Modified Graphite Electrode for Selective Determination of Dopamine
    Zhang, Jing
    Liu, Chang
    E, Yifeng
    Yue, Jingli
    Chen, Lianshan
    Li, Donghui
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (18) : 5951 - 5954
  • [30] DETERMINATION OF COPPER-ACETATE FORMATION CONSTANT IN ALCOHOL WATER MIXED-SOLUTION BY THE USE OF THE COPPER-ION SELECTIVE ELECTRODE
    KAMATA, S
    TOYOHARA, M
    NIPPON KAGAKU KAISHI, 1985, (02) : 185 - 188