Selective determination of cuprous ion in copper dissolving solution based on bathocuproine-modified expanded graphite electrode

被引:0
|
作者
Chen, Xiaohui [1 ]
Sun, Yufa [2 ]
Wang, Wenchang [2 ]
Chen, Zhidong [2 ]
Ming, Zhiyao [3 ]
机构
[1] Changzhou Inst Technol, Sch Chem & Mat Engn, Changzhou 213032, Peoples R China
[2] Changzhou Univ, Sch Petrochem & Engn, Changzhou 213164, Peoples R China
[3] Jiangsu Mingfeng Elect Mat Technol Co Ltd, Changzhou 213341, Peoples R China
基金
中国国家自然科学基金;
关键词
Cuprous ions; Bathocuproine; Expanded graphite; Specific adsorption; Selective determination; ELECTROPLATING SOLUTION; CU(I); COMPLEXES; COMPOSITE; CHLORIDE; SENSOR; ACID;
D O I
10.1007/s44211-023-00358-w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The presence of cuprous ions in the copper-dissolving solution significantly affects the microstructure of copper plated surface. Fewer quantitative analyses of cuprous ions in the copper foil productive process had rarely been involved so far. In the present work, a novel electrochemical sensor of the bathocuproine (BCP) modified expanded graphite (EG) electrode was developed for the selective determination of cuprous ions. EG has a large surface area, good adsorption, and excellent electrochemical performance which remarkably promoted analytical sensitivity. Meanwhile, the selective determination of the BCP-EG electrode for cuprous ions in the coexistence of ten thousand times of copper ions have been achieved on the benefit of the special coordination of BCP to cuprous ions. In the coexistence of 50 g/L copper ions, the analytical performance of the BCP-EG electrode for the determination of cuprous ions had been examined. The results represented a wide detection range of cuprous ions in the range of 1.0 mu g/L-5.0 mg/L, with a low detection limit of 0.18 mu g/L (S/N = 3) and the BCP-EG electrode has great selectivity to cuprous ions in presence of various interferences. The analytical selectively for cuprous ions supported by the proposed electrode would be a potential analytical tool for quality improvement in electrolytic copper foil manufacturing.
引用
收藏
页码:1465 / 1473
页数:9
相关论文
共 50 条
  • [31] Schiff Base modified on CPE electrode and PCB gold electrode for selective determination of silver ion
    Leepheng, Piyawan
    Suramitr, Songwut
    Phromyothin, Darinee
    SIAM PHYSICS CONGRESS 2017 (SPC2017), 2017, 901
  • [32] COMPLEXOMETRIC DETERMINATION OF COPPER AND IRON IN SILICON WITH A CUPRIC ION-SELECTIVE ELECTRODE
    TADDIA, M
    MICROCHEMICAL JOURNAL, 1977, 22 (03) : 369 - 375
  • [33] DETERMINATION OF FLUORIDE IN COPPER METALLURGY MATERIALS WITH A FLUORIDE ION-SELECTIVE ELECTRODE
    CZICHON, P
    FLIGIER, J
    CREGOROWICZ, Z
    CHEMIA ANALITYCZNA, 1985, 30 (02): : 313 - 318
  • [34] Analytical determination of apparent stability constants using a copper ion selective electrode
    Byrne, L. A.
    Hynes, M. J.
    Connolly, C. D.
    Murphy, R. A.
    JOURNAL OF INORGANIC BIOCHEMISTRY, 2011, 105 (12) : 1656 - 1661
  • [35] A novel electrochemical immunosensor based on poly(m-aminophenol) modified expanded graphite electrode
    Tao, Yongxin
    Liu, Qingxin
    Li, Wei
    Xue, Huaiguo
    Qin, Yong
    Ge, Jianfeng
    Kong, Yong
    SYNTHETIC METALS, 2013, 183 : 50 - 56
  • [36] A novel sodium dodecyl benzene sulfonate modified expanded graphite paste electrode for sensitive and selective determination of dopamine in the presence of ascorbic acid and uric acid
    Zhang, Jing
    Song, Xin-he
    Ma, Sa
    Wang, Xue
    Wang, Wen-chang
    Chen, Zhi-dong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 795 : 10 - 16
  • [37] An Electrochemical Sensor for Simultaneous Determination of Ponceau 4R and Tartrazine Based on an Ionic Liquid Modified Expanded Graphite Paste Electrode
    Zhang, Jing
    Wang, Xue
    Zhang, Shibo
    Wang, Wenchang
    Hojo, Masashi
    Chen, Zhidong
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (09) : H453 - H457
  • [38] Highly selective electrogenerated chemiluminescence (ECL) for sulfide ion determination at multi-wall carbon nanotubes-modified graphite electrode
    Huang, Rongfu
    Zheng, Xingwang
    Qu, Yingjuan
    ANALYTICA CHIMICA ACTA, 2007, 582 (02) : 267 - 274
  • [39] COPPER ION-SELECTIVE ELECTRODE BASED ON A CHALCOGENIDE GLASS MEMBRANE
    AWASTHI, SP
    SHENOY, NS
    RADHAKRISHNAN, TP
    ANALYST, 1994, 119 (06) : 1361 - 1362
  • [40] Electrochemical Sensor Based on a Modified Graphite Screen Printed Electrode for Amitriptyline Determination
    Surface Engineering and Applied Electrochemistry, 2022, 58 : 100 - 108