Synergistic combination of natural deep eutectic solvent and chemical vapor generation for trace determination of As, Cd, Hg and Pb in drug samples by inductively coupled plasma optical emission spectrometry

被引:6
|
作者
Abellan-Martin, Sergio J. [1 ,2 ]
Perez, Jorge [1 ,2 ]
Pinheiro, Fernanda C. [3 ]
Nobrega, Joaquim A. [4 ]
Aguirre, Miguel Angel [1 ,2 ]
Vidal, Lorena [1 ,2 ]
Canals, Antonio [1 ,2 ]
机构
[1] Univ Alicante, Dept Analyt Chem & Food Sci, Fac Sci, POB 99, Alicante 03080, Spain
[2] Univ Alicante, Univ Inst Mat, Fac Sci, POB 99, Alicante 03080, Spain
[3] Univ Fed Minas Gerais, Dept Chem, ICEX, Ave Antonio Carlos, 6627, BR-31270901 Belo Horizonte, MG, Brazil
[4] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, POB 676, BR-13560970 Sao Carlos, SP, Brazil
来源
关键词
Pharmaceutical samples; Microwave-assisted digestion; Dispersive liquid-liquid microextraction; Natural deep eutectic solvent; Multinebulizer; Chemical vapor generation; LIQUID-LIQUID MICROEXTRACTION; HYDRIDE GENERATION; IMPURITIES; CADMIUM; MERCURY; SE;
D O I
10.1016/j.sampre.2023.100084
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and environmentally friendly analytical method for simultaneous determination of As, Cd, Hg and Pb in drug samples by inductively coupled plasma optical emission spectrometry (ICP OES) has been developed. In order to increase the sensitivity of the analysis, a multinebulizer has been used for chemical vapor generation (CVG) after a dispersive liquid-liquid microextraction (DLLME) procedure using a natural deep eutectic solvent (NADES) as extractant solvent. The factors affecting analyte extraction and on-line chemical vapor generation have been optimized by multivariate analysis. Under optimized conditions, DLLME-CVG-ICP OES improved limit of quantitation (LOQ) values on average 50-fold higher compared with direct ICP OES analysis and afforded an increase of the sensitivity (i.e., enrichment factor) on average 25-times higher than those obtained with CVG-ICP OES analysis. According to the United States Pharmacopoeia (USP) Chapter 232, it means LOQ values are on average 4.3-times lower than their respective 0.3J values for the target-elements from class 1. Trueness has been evaluated by recovery experiments following USP recommendations for two oral drug samples in solid dosage form (i.e., commercial dosage tablets). In addition, the greenness of the developed method has been evaluated using the AGREEprep metrics, showing an excellent green character since it includes the miniaturization of the sample preparation procedure using a reduced volume (i.e., few microliters) of a non-hazardous extractant solvent for multielemental analysis.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Chemical vapor generation sample introduction for the determination of As, Cd, Sb, Hg, and Pb in nail polish by inductively coupled plasma mass spectrometry
    Huang, Fan-Feng
    Jiang, Shiuh-Jen
    Chen, Yen-Ling
    Sahayam, A. C.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 140 : 84 - 88
  • [2] Determination of major and trace elements in plant samples by inductively coupled plasma optical emission spectrometry with deep eutectic solvent extraction based on choline chloride and carboxylic acids
    Zhao, Wenzhi
    Sun, Yanfeng
    Wei, Xiaoyong
    Niu, Guangyuan
    Zhou, Chuanfang
    ANALYTICAL METHODS, 2023, 15 (34) : 4275 - 4281
  • [3] Determination of Hg and Pb in Fuels by Inductively Coupled Plasma Mass Spectrometry Using Flow Injection Chemical Vapor Generation
    Chen, Feng-yi
    Jiang, Shiuh-Jen
    ANALYTICAL SCIENCES, 2009, 25 (12) : 1471 - 1476
  • [4] Determination of Hg and Pb in Fuels by Inductively Coupled Plasma Mass Spectrometry Using Flow Injection Chemical Vapor Generation
    Feng-yi Chen
    Shiuh-Jen Jiang
    Analytical Sciences, 2009, 25 : 1471 - 1476
  • [5] Sensitive determination of Ag, Bi, Cd, Hg, Pb, Tl, and Zn by inductively coupled plasma optical emission spectrometry combined with the microplasma-assisted vapor generation
    Greda, Krzysztof
    Welna, Maja
    Szymczycha-Madeja, Anna
    Pohl, Pawel
    TALANTA, 2022, 249
  • [6] Slurry Sampling Flow Injection Chemical Vapor Generation Inductively Coupled Plasma Mass Spectrometry for the Determination of As, Cd, and Hg in Cereals
    Chen, Feng-Yi
    Jiang, Shiuh-Jen
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (15) : 6564 - 6569
  • [7] Determination of As, Hg and Pb in herbs using slurry sampling flow injection chemical vapor generation inductively coupled plasma mass spectrometry
    Tai, Chia-Yi
    Jiang, Shiuh-Jen
    Sahayam, A. C.
    FOOD CHEMISTRY, 2016, 192 : 274 - 279
  • [8] Preconcentration of Copper and Lead Using Deep Eutectic Solvent Modified Magnetic Nanoparticles and Determination by Inductively Coupled Plasma Optical Emission Spectrometry
    Liu, Qi
    Huang, Xueying
    Liang, Pei
    ATOMIC SPECTROSCOPY, 2020, 41 (01) : 36 - 42
  • [9] Determination of Hg and Pb in compact fluorescent lamp by slurry sampling inductively coupled plasma optical emission spectrometry
    dos Santos, Eder Jose
    Herrmann, Amanda Beatriz
    Vieira, Fabiula
    Sato, Charyane Satie
    Correa, Quelcy Barreiros
    Maranhao, Tatiane Andrade
    Tormen, Luciano
    Curtius, Adilson Jose
    MICROCHEMICAL JOURNAL, 2010, 96 (01) : 27 - 31
  • [10] Sequential determination of Pb, Cd and Hg by flow injection-chemical vapour generation-inductively coupled plasma mass spectrometry
    Sanchez Trujillo, Irene
    Garcia de Torres, Amparo
    Vereda Alonso, Elisa I.
    Cano Pavon, Jose M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (11) : 1772 - 1780