Reverse scan body: The scan pattern affects the fit of complete-arch prototype prostheses

被引:5
|
作者
Papaspyridakos, Panos [1 ,2 ,5 ]
Bedrossian, E. Armand [3 ]
Ntovas, Panagiotis [1 ]
Kudara, Yukio [1 ]
Bokhary, Abdullah [4 ]
Chochlidakis, Konstantinos [2 ]
机构
[1] Tufts Sch Dent Med, Dept Prosthodont, Boston, MA USA
[2] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont, Rochester, NY USA
[3] Univ Washington, Dept Prosthodont, Seattle, WA USA
[4] King Abdulaziz Univ, Fac Dent, Dept Dent Publ Hlth, Jeddah, Saudi Arabia
[5] Tufts Univ, Dept Prosthodont, Sch Dent Med, One Kneeland St, Boston, MA 02111 USA
关键词
complete-arch digital scan; complete-arch prototypes; complete digital workflow; digital implant workflow; digital scan; full arch implant prostheses; full-arch digital scan; full-arch implant prostheses; full arch implant rehabilitation; prosthesis accuracy of fit; reverse scan body; scan pattern; IMPLANT IMPRESSIONS; ACCURACY; COMPLICATIONS; TECHNOLOGY; IMPACT;
D O I
10.1111/jopr.13772
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeTo assess the effect of different scan patterns on the fit of implant-supported complete-arch prototype prostheses fabricated via a complete digital extraoral protocol with a reverse scan body.Materials and MethodsA mandibular cast with four multi-unit abutment (MUA) implant analogs with adequate antero-posterior spread served as the reference cast, simulating a common clinical patient situation, and a polymethylmethacrylate interim screw-retained prosthesis was fabricated on it. Novel reverse scan bodies were connected to the interim prosthesis on the intaglio of the MUA abutments and extraoral scanning was performed with a white light intraoral scanner (TRIOS 4; 3 shape) and three different scan patterns: starting from the occlusal surface of the interim prosthesis (O-group), starting from the intaglio (I-group), and helix pattern (H-group). The resulting STL files from the three groups were then imported to computer-aided design (CAD) software and after the digital design, the STL files were exported to a computer-aided manufacturing (CAM) milling machine which generated a total of 15 CAD-CAM milled prototype prostheses per group. Two clinicians assessed the fit of each digitally fabricated prototype prosthesis on the reference cast, utilizing the screw-resistance test and radiographic evaluation. Fisher's exact test was used to test the difference between the three groups, and Cohen's k-score was used to assess the inter-examiner agreement.ResultsOut of the three different groups, the O-group scan pattern led to 100% prosthesis fit, while the prototype prostheses generated from I- and H-groups had 80% and 53% fit, respectively. The results were statistically significant (p = 0.008).ConclusionsOcclusal scan pattern leads to fitting milled prototype prostheses after extraoral scanning with reverse scan bodies without intraoral implant data acquisition.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 50 条
  • [31] Effect of scan powder and scanning technology on measured deviations of complete-arch implant supported frameworks digitized with industrial and intraoral scanners
    Donmez, Mustafa Borga
    Cakmak, Gulce
    Dede, Dogu Omur
    Kucukekenci, Ahmet Serkan
    Lu, Wei-En
    Schumacher, Fernanda Lang
    Revilla-Leon, Marta
    Yilmaz, Burak
    JOURNAL OF DENTISTRY, 2023, 138
  • [32] Fit of 3Y-TZP complete-arch implant-supported fixed dental prostheses before and after porcelain veneering
    Svanborg, Per
    Saarva, Veronika Norstrom
    Stenport, Victoria
    Eliasson, Alf
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (02): : 137 - 141
  • [33] Accuracy of intraoral scanners in different complete arch scan patterns
    Pattamavilai, Sakaorat
    Ongthiemsak, Chakree
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 155 - 162
  • [34] Feasibility of using an intraoral scanner for a complete arch digital scan, part 2: A comparison of scan strategies
    Son, KeunBaDa
    Jin, Myoung-Uk
    Lee, Kyu-Bok
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (02): : 341 - 349
  • [35] Complete-arch accuracy of seven intraoral scanners measured by the virtual-fit method
    Borbola, Daniel
    Mikolicz, Akos
    Romanszky, Laszlo
    Sersli, Gyorgy
    DeFee, Michael
    Renne, Walter
    Vag, Janos
    JOURNAL OF DENTISTRY, 2024, 149
  • [36] Five-year results with fixed complete-arch mandibular prostheses supported by 4 implants
    Eliasson, A
    Palmqvist, S
    Svenson, B
    Sondell, K
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2000, 15 (04) : 505 - 510
  • [37] Number of implants placed for complete-arch fixed prostheses: A systematic review and meta-analysis
    Polido, Waldemar Daudt
    Aghaloo, Tara
    Emmett, Thomas W.
    Taylor, Thomas D.
    Morton, Dean
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 154 - 183
  • [38] A METHOD OF REPAIRING OCCLUSALLY WORN OR BROKEN-DOWN COMPLETE-ARCH FIXED IMPLANT PROSTHESES
    PIGNO, MA
    FINGER, I
    JOURNAL OF PROSTHETIC DENTISTRY, 1994, 72 (02): : 204 - 209
  • [39] Complete-arch implant-supported monolithic zirconia fixed dental prostheses: A systematic review
    Abdulmajeed, Aous A.
    Lim, Kevin G.
    Naerhi, Timo O.
    Cooper, Lyndon F.
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06): : 672 - 677
  • [40] Effect of framework material on the color of implant-supported complete-arch fixed dental prostheses
    Yilmaz, Burak
    Alp, Gulce
    Johnston, William M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (01): : 69 - 75