Reverse scan body: The scan pattern affects the fit of complete-arch prototype prostheses

被引:5
|
作者
Papaspyridakos, Panos [1 ,2 ,5 ]
Bedrossian, E. Armand [3 ]
Ntovas, Panagiotis [1 ]
Kudara, Yukio [1 ]
Bokhary, Abdullah [4 ]
Chochlidakis, Konstantinos [2 ]
机构
[1] Tufts Sch Dent Med, Dept Prosthodont, Boston, MA USA
[2] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont, Rochester, NY USA
[3] Univ Washington, Dept Prosthodont, Seattle, WA USA
[4] King Abdulaziz Univ, Fac Dent, Dept Dent Publ Hlth, Jeddah, Saudi Arabia
[5] Tufts Univ, Dept Prosthodont, Sch Dent Med, One Kneeland St, Boston, MA 02111 USA
关键词
complete-arch digital scan; complete-arch prototypes; complete digital workflow; digital implant workflow; digital scan; full arch implant prostheses; full-arch digital scan; full-arch implant prostheses; full arch implant rehabilitation; prosthesis accuracy of fit; reverse scan body; scan pattern; IMPLANT IMPRESSIONS; ACCURACY; COMPLICATIONS; TECHNOLOGY; IMPACT;
D O I
10.1111/jopr.13772
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeTo assess the effect of different scan patterns on the fit of implant-supported complete-arch prototype prostheses fabricated via a complete digital extraoral protocol with a reverse scan body.Materials and MethodsA mandibular cast with four multi-unit abutment (MUA) implant analogs with adequate antero-posterior spread served as the reference cast, simulating a common clinical patient situation, and a polymethylmethacrylate interim screw-retained prosthesis was fabricated on it. Novel reverse scan bodies were connected to the interim prosthesis on the intaglio of the MUA abutments and extraoral scanning was performed with a white light intraoral scanner (TRIOS 4; 3 shape) and three different scan patterns: starting from the occlusal surface of the interim prosthesis (O-group), starting from the intaglio (I-group), and helix pattern (H-group). The resulting STL files from the three groups were then imported to computer-aided design (CAD) software and after the digital design, the STL files were exported to a computer-aided manufacturing (CAM) milling machine which generated a total of 15 CAD-CAM milled prototype prostheses per group. Two clinicians assessed the fit of each digitally fabricated prototype prosthesis on the reference cast, utilizing the screw-resistance test and radiographic evaluation. Fisher's exact test was used to test the difference between the three groups, and Cohen's k-score was used to assess the inter-examiner agreement.ResultsOut of the three different groups, the O-group scan pattern led to 100% prosthesis fit, while the prototype prostheses generated from I- and H-groups had 80% and 53% fit, respectively. The results were statistically significant (p = 0.008).ConclusionsOcclusal scan pattern leads to fitting milled prototype prostheses after extraoral scanning with reverse scan bodies without intraoral implant data acquisition.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 50 条
  • [21] Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study
    Pozzi, Alessandro
    Agliardi, Enrico
    Lio, Fabrizio
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 172 - 180
  • [22] Digital workflow for double complete arch zirconia prostheses utilizing a novel scan body (vol 31, pg 4, 2022)
    Marinis
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (03): : 271 - 271
  • [23] Complete digital workflow in prosthesis prototype fabrication for complete-arch implant rehabilitation: A technique
    Papaspyridakos, Panos
    Chen, Yo-wei
    Gonzalez-Gusmao, Ilenia
    Att, Wael
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (03): : 189 - 192
  • [24] Ensuring passivity and retrievability for immediate complete-arch implant-supported prostheses
    Spazzin, Aloisio Oro
    Camargo, Bernardo
    Bacchi, Atais
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (02): : 214 - 217
  • [25] An additively manufactured intraoral scan body for aiding complete-arch intraoral implant digital scans with guided integration of 3D virtual representation
    Gabriel Perez-Giugovaz, Marcelo
    Mosier, Meredith
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01): : 38 - 43
  • [26] Effect of scan pattern on the scan accuracy of a combined healing abutment scan body system
    Yilmaz, Hakan
    Arinc, Hakan
    Cakmak, Gulce
    Atalay, Sevda
    Donmez, Mustafa Borga
    Koekat, Ali Murat
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 110 - 118
  • [27] Effect of splinting scan bodies on trueness of complete-arch implant impression using different intraoral scanners: an in vitro study
    Retana, Luciano
    Nejat, Amir H.
    Pozzi, Alessandro
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2023, 26 (01) : 19 - 28
  • [28] Conventional open-tray impression versus intraoral digital scan for implant-level complete-arch impression
    Kim, Kyoung Rok
    Seo, Kyoung-young
    Kim, Sunjai
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (06): : 543 - 549
  • [29] Accuracy of intraoral scanning using modified scan bodies for complete arch implant-supported fixed prostheses
    Li, Yanxi
    Fang, He
    Yan, Yuwei
    Geng, Wei
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05): : 994e1 - 994e8
  • [30] Complete-arch Implant-supported Composite Pressed Restorations Fixed Dental Prostheses
    Mihali, Sorin Gheorghe
    Bratu, Emanuel Adrian
    Rusu, Laura Cristina
    REVISTA DE CHIMIE, 2017, 68 (12): : 3006 - 3009