Is three-point fixation needed to mechanically stabilize zygomaticomaxillary complex fractures?

被引:4
|
作者
Arjmand, Hanieh [1 ,2 ]
Billig, Allan [4 ]
Clement, Allison [1 ]
Hopfgartner, Adam [1 ]
Whyne, Cari M. [1 ,2 ,3 ]
Fialkov, Jeffrey A. [2 ,3 ,4 ]
机构
[1] Sunnybrook Res Inst, Orthopaed Biomech Lab, Toronto, ON, Canada
[2] Univ Toronto, Inst Biomed Engn, Toronto, ON, Canada
[3] Univ Toronto, Dept Surg, Toronto, ON, Canada
[4] Sunnybrook Hlth Sci Ctr, Div Plast Surg, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Zygomaticomaxillary complex fracture fixation; Craniomaxillofacial; Experimental testing; Fracture displacement; TRIPOD FRACTURES; SKELETON;
D O I
10.1016/j.bjps.2023.04.086
中图分类号
R61 [外科手术学];
学科分类号
摘要
Fixation is critical in zygomaticomaxillary complex (ZMC) fractures to avoid malunion; however, controversy exists as to how much hardware is required to achieve adequate stability. Current fixation regimens may not represent the minimum stabilization needed for uneventful healing. Craniomaxillofacial (CMF) computational models have shown limited load transmission through the infraorbital rim (IOR), and a previous experimental study of ZMC fractures has suggested that IOR plating does not alter CMF bone strain patterns. This study aimed to measure the impact of stabilization on fracture site displacement under muscle loading, testing the hypothesis that three-point fixation is not critical for ZMC fracture stability. Four ZMC complex fractures were simulated on two cadaveric samples and stabilized with three-point plating. Displacements simulating mouth openings of 20 mm and 30 mm were applied to the mandible using a custom apparatus. Fracture gap displacement under load was measured at multiple points along each fracture line, and bone strain was captured using a combination of uniaxial and rosette gauges. Data capture was repeated with the IOR plate removed (two-point fixation) and with the zygomaticomaxillary plate removed (one-point fixation). Fracture displacement under muscle loading was consistent, with gaps of less than 1 mm in 95% of cases (range 0.05-1.44 mm), reflecting clinical stability. Large variabilities were observed in the strain measurements, which may reflect the complexity of CMFS load patterns and the sensitivity of strain values to gauge placement. This study supports the concept of hardware reduction, suggesting that two-point (or even one-point) fixation may provide suffi- cient stability for a ZMC fracture under applied muscle loading. & COPY; 2023 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [41] Buccal fat pad and subperiosteal midface lifts in conjunction with open reduction and internal fixation to treat fractures of the zygomaticomaxillary complex
    Bottini, G. B.
    Berridge, N.
    Messiha, A.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2018, 56 (03): : 230 - 231
  • [42] Microplate Versus Combined Microplate-Miniplate in Fixation of Zygomaticomaxillary Complex Fractures: An In-Silico Analysis of Biomechanical Parameters
    Mohammadi Khanaghah, Xaniar
    Pourlak, Tannaz
    Mortazavi, Ali
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2024, 23 (03): : 524 - 530
  • [43] The Arthroscopic Three-Point Fixation for Anterior Cruciate Ligament Avulsion Fracture: Surgical Technique
    Chanlalit, Cholawish
    Mahasupachai, Nattakorn
    Sakdapanichkul, Chidchanok
    ARTHROSCOPY TECHNIQUES, 2023, 12 (10): : e1679 - e1685
  • [44] An Anthropometric and Three-Dimensional Computed Tomographic Evaluation of Two-Point Fixation of Zygomatic Complex Fractures
    Jo, Taehee
    Kim, Junhyung
    ARCHIVES OF PLASTIC SURGERY-APS, 2014, 41 (05): : 493 - 499
  • [45] Comparison of Two Posterior Three-Point Fixation Techniques for Treating Reducible Atlantoaxial Dislocation
    Zhao, Wenlong
    Wu, Yaming
    Hu, Wei
    Ni, Bin
    Guo, Qunfeng
    Chen, Jinshui
    Guo, Xiang
    SPINE, 2019, 44 (01) : E60 - E66
  • [46] The use of the three-point index in the management of extra-articular distal radius fractures
    Siddiqui, Bobby
    Senevirathna, Shanaka
    Hayes, Alistair
    Rajeev, Aysha
    Kakkar, Rahul
    Harrison, John
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (01): : 42 - 47
  • [47] Polyaxial pedicle screw external fixation to stabilize oblique mandibular fractures in three standing, sedated horses
    Nelson, Brad B.
    Easley, Jack
    Steward, Sara K. T.
    Smanik, Lauren E.
    Koch, Drew W.
    Rawlinson, Jennifer E.
    Easley, Jeremiah T.
    VETERINARY SURGERY, 2021, 50 (03) : 659 - 667
  • [48] Finite Element Analysis of 2-and 3-Point Internal Fixation Methods for the Treatment of Zygomaticomaxillary Complex Fracture
    Li, Yan
    Wu, Pengsen
    Liu, Shuyi
    Tang, Meiting
    Yu, Shen
    Kikkawa, Don O.
    Lu, Wei
    JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (08) : 2208 - 2212
  • [49] Posterior atlantoaxial three-point fixation: comparison of intraoperative performance between open and percutaneous techniques
    Schmidt, R
    Richter, M
    Gleichsner, F
    Geiger, P
    Puhl, W
    Cakir, B
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (03) : 150 - 156
  • [50] Posterior atlantoaxial three-point fixation: comparison of intraoperative performance between open and percutaneous techniques
    René Schmidt
    Marcus Richter
    Franziska Gleichsner
    Peter Geiger
    Wolfhart Puhl
    Balkan Cakir
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 150 - 156