Is three-point fixation needed to mechanically stabilize zygomaticomaxillary complex fractures?

被引:4
|
作者
Arjmand, Hanieh [1 ,2 ]
Billig, Allan [4 ]
Clement, Allison [1 ]
Hopfgartner, Adam [1 ]
Whyne, Cari M. [1 ,2 ,3 ]
Fialkov, Jeffrey A. [2 ,3 ,4 ]
机构
[1] Sunnybrook Res Inst, Orthopaed Biomech Lab, Toronto, ON, Canada
[2] Univ Toronto, Inst Biomed Engn, Toronto, ON, Canada
[3] Univ Toronto, Dept Surg, Toronto, ON, Canada
[4] Sunnybrook Hlth Sci Ctr, Div Plast Surg, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Zygomaticomaxillary complex fracture fixation; Craniomaxillofacial; Experimental testing; Fracture displacement; TRIPOD FRACTURES; SKELETON;
D O I
10.1016/j.bjps.2023.04.086
中图分类号
R61 [外科手术学];
学科分类号
摘要
Fixation is critical in zygomaticomaxillary complex (ZMC) fractures to avoid malunion; however, controversy exists as to how much hardware is required to achieve adequate stability. Current fixation regimens may not represent the minimum stabilization needed for uneventful healing. Craniomaxillofacial (CMF) computational models have shown limited load transmission through the infraorbital rim (IOR), and a previous experimental study of ZMC fractures has suggested that IOR plating does not alter CMF bone strain patterns. This study aimed to measure the impact of stabilization on fracture site displacement under muscle loading, testing the hypothesis that three-point fixation is not critical for ZMC fracture stability. Four ZMC complex fractures were simulated on two cadaveric samples and stabilized with three-point plating. Displacements simulating mouth openings of 20 mm and 30 mm were applied to the mandible using a custom apparatus. Fracture gap displacement under load was measured at multiple points along each fracture line, and bone strain was captured using a combination of uniaxial and rosette gauges. Data capture was repeated with the IOR plate removed (two-point fixation) and with the zygomaticomaxillary plate removed (one-point fixation). Fracture displacement under muscle loading was consistent, with gaps of less than 1 mm in 95% of cases (range 0.05-1.44 mm), reflecting clinical stability. Large variabilities were observed in the strain measurements, which may reflect the complexity of CMFS load patterns and the sensitivity of strain values to gauge placement. This study supports the concept of hardware reduction, suggesting that two-point (or even one-point) fixation may provide suffi- cient stability for a ZMC fracture under applied muscle loading. & COPY; 2023 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [21] Minimally Invasive Single-Point Stabilization of Zygomaticomaxillary Complex Fractures
    Elkahwagi, Mohamed
    Eldegwi, Ahmed
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2022, 21 (04): : 1355 - 1362
  • [22] COMPLEX STRUCTURES ON THREE-POINT SPACE
    Bhattacharjee, Suvrajit
    Goswami, Debashish
    INFINITE DIMENSIONAL ANALYSIS, QUANTUM PROBABILITY AND RELATED TOPICS, IDAQP 2024, 2024, : 77 - 101
  • [23] Analysis of the accuracy of a novel preformed osteosynthesis plate for the reduction and fixation of zygomaticomaxillary complex fractures
    Poxleitner, Philipp
    Steybe, David
    Bublitz, Britta
    Schlager, Stefan
    Fuessinger, Marc Anton
    Voss, Pit Jacob
    Schmelzeisen, Rainer
    Cornelius, Carl-Peter
    Metzger, Marc
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (06) : 951 - 958
  • [24] Role of finite element analysis for selection of single point fixation in zygomaticomaxillary complex fracture
    Shaimaa Mohsen Refahee
    Mahmoud Elsayed Khalifa
    Mohamed Gamal Askar
    Maram N. Breshah
    BMC Oral Health, 24
  • [25] Comparisons among four types of absorbable plates used for internal fixation of zygomaticomaxillary complex fractures
    Chu, Seung Gyun
    Lee, Joon Seok
    Lee, Jeong Woo
    Yang, Jung Dug
    Chung, Ho Yun
    Cho, Byung Chae
    Choi, Kang Young
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (03) : 383 - 388
  • [26] Role of finite element analysis for selection of single point fixation in zygomaticomaxillary complex fracture
    Refahee, Shaimaa Mohsen
    Khalifa, Mahmoud Elsayed
    Askar, Mohamed Gamal
    Breshah, Maram N.
    BMC ORAL HEALTH, 2024, 24 (01)
  • [27] Feasibility of 4-Point Fixation Using the Preauricular Approach in a Zygomaticomaxillary Complex Fracture
    Choi, Kang Young
    Ryu, Dong Wan
    Yang, Jung Dug
    Chung, Ho Yun
    Cho, Byung Chae
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (02) : 557 - 562
  • [28] Comparison of the biomechanical properties of internal fixation materials for zygomaticomaxillary complex fractures, A finite element analysis
    Zeng, Xueying
    Li, Yang
    Sun, Hetian
    Li, Yan
    Kikkawa, Don O.
    Lu, Wei
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2024, 125 (05)
  • [29] Surgical treatment of fractures of the zygomaticomaxillary complex: effect of fixation on repositioning and stability. A systematic review
    Raghoebar, Iva I.
    Rozema, Frederik R.
    de Lange, Jan
    Dubois, Leander
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2022, 60 (04): : 397 - 411
  • [30] Fixation Points in the Treatment of Traumatic Zygomaticomaxillary Complex Fractures: A Systematic Review and Meta-Analysis
    Jazayeri, Hossein E.
    Khavanin, Nima
    Yu, Jason W.
    Lopez, Joseph
    Shamliyan, Tatyana
    Peacock, Zachary S.
    Dorafshar, Amir H.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 77 (10) : 2064 - 2073