Is three-point fixation needed to mechanically stabilize zygomaticomaxillary complex fractures?

被引:4
|
作者
Arjmand, Hanieh [1 ,2 ]
Billig, Allan [4 ]
Clement, Allison [1 ]
Hopfgartner, Adam [1 ]
Whyne, Cari M. [1 ,2 ,3 ]
Fialkov, Jeffrey A. [2 ,3 ,4 ]
机构
[1] Sunnybrook Res Inst, Orthopaed Biomech Lab, Toronto, ON, Canada
[2] Univ Toronto, Inst Biomed Engn, Toronto, ON, Canada
[3] Univ Toronto, Dept Surg, Toronto, ON, Canada
[4] Sunnybrook Hlth Sci Ctr, Div Plast Surg, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Zygomaticomaxillary complex fracture fixation; Craniomaxillofacial; Experimental testing; Fracture displacement; TRIPOD FRACTURES; SKELETON;
D O I
10.1016/j.bjps.2023.04.086
中图分类号
R61 [外科手术学];
学科分类号
摘要
Fixation is critical in zygomaticomaxillary complex (ZMC) fractures to avoid malunion; however, controversy exists as to how much hardware is required to achieve adequate stability. Current fixation regimens may not represent the minimum stabilization needed for uneventful healing. Craniomaxillofacial (CMF) computational models have shown limited load transmission through the infraorbital rim (IOR), and a previous experimental study of ZMC fractures has suggested that IOR plating does not alter CMF bone strain patterns. This study aimed to measure the impact of stabilization on fracture site displacement under muscle loading, testing the hypothesis that three-point fixation is not critical for ZMC fracture stability. Four ZMC complex fractures were simulated on two cadaveric samples and stabilized with three-point plating. Displacements simulating mouth openings of 20 mm and 30 mm were applied to the mandible using a custom apparatus. Fracture gap displacement under load was measured at multiple points along each fracture line, and bone strain was captured using a combination of uniaxial and rosette gauges. Data capture was repeated with the IOR plate removed (two-point fixation) and with the zygomaticomaxillary plate removed (one-point fixation). Fracture displacement under muscle loading was consistent, with gaps of less than 1 mm in 95% of cases (range 0.05-1.44 mm), reflecting clinical stability. Large variabilities were observed in the strain measurements, which may reflect the complexity of CMFS load patterns and the sensitivity of strain values to gauge placement. This study supports the concept of hardware reduction, suggesting that two-point (or even one-point) fixation may provide suffi- cient stability for a ZMC fracture under applied muscle loading. & COPY; 2023 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [31] Management of tripod fractures (zygomaticomaxillary complex) 1 point and 2 point fixations: A 5-year review
    Balakrishnan, K.
    Ebenezer, Vijay
    Dakir, Abu
    Kumar, Saravana
    Prakash, D.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2015, 7 (05): : S242 - S247
  • [32] Inadequate 'three-point' proximal fixation predicts failure of the Gamma nail
    Abram, S. G. F.
    Pollard, T. C. B.
    Andrade, A. J. M. D.
    BONE & JOINT JOURNAL, 2013, 95B (06): : 825 - 830
  • [33] Three-point stapled fixation technique to manage ileostomy spout retraction
    Behrenbruch, Corina
    Carr, Gareth
    Johnston, Michael
    Woods, Rodney
    ANZ JOURNAL OF SURGERY, 2019, 89 (04) : 423 - 424
  • [34] Surgical strategies for recurrent hiatal hernia: three-point fundoplication fixation
    Chu, Yuxiao
    Liu, Yanyang
    Hua, Rong
    Yao, Qiyuan
    BMC SURGERY, 2025, 25 (01)
  • [35] Three-point fixation of stomach to abdominal wall in the percutaneous endoscopic gastrostomy procedure
    Kusaka, K
    Itoh, T
    Kawaura, K
    Yamakawa, J
    Takahashi, T
    Kanda, T
    ENDOSCOPY, 2005, 37 (05) : 494 - 494
  • [36] Retroperitoneoscopic nephropexy for symptomatic nephroptosis using a modified three-point fixation technique
    Wyler, SF
    Sulser, T
    Casella, R
    Hauri, D
    Bachmann, A
    UROLOGY, 2005, 66 (03) : 644 - 648
  • [37] Original three-point fixation technique for sutured posterior chamber intraocular lens
    Beltrame, G
    Driussi, GB
    Salvetat, ML
    Chizzolini, M
    Scuderi, B
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2002, 12 (03) : 219 - 224
  • [38] Three-point flanged optic piercing intrascleral fixation of multifocal intraocular lenses
    Eom, Youngsub
    Jeon, Hyun Sun
    Kim, Seong-Jae
    Kim, Dong Hyun
    Song, Jong Suk
    Kim, Dooho Brian
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2025, 73 (03) : 455 - 461
  • [39] The value of the three-point index in predicting redisplacement of diaphyseal fractures of the forearm in children
    Iltar, S.
    Alemdaroglu, K. B.
    Say, F.
    Aydogan, N. H.
    BONE & JOINT JOURNAL, 2013, 95B (04): : 563 - 567
  • [40] Three-Column Fixation for Complex Tibial Plateau Fractures
    Luo, Cong-Feng
    Sun, Hui
    Zhang, Bo
    Zeng, Bing-Fang
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (11) : 683 - 692