Agreement of Temperatures Measured Using a Non-Contact Infrared Thermometer With a Rectal Digital Thermometer in Horses

被引:3
|
作者
Easterwood, Leslie [1 ,3 ]
Cohen, Noah D. [2 ]
机构
[1] Texas A&M Univ, Dept Large Anim Clin Sci, College Stn, TX USA
[2] Texas A&M Univ, Dept Large Anim Clin Sci, Equine Infect Dis Lab, College Stn, TX USA
[3] Texas A&M Univ, Dept Large Anim Clini cal Sci, MS 4475, College Stn, TX 77843 USA
关键词
Horses; Noncontact thermometry; Rectal thermometry; Neck; Forehead; BODY-TEMPERATURE; MICROCHIP; ACCURACY; CHILDREN; FEVER;
D O I
10.1016/j.jevs.2023.104243
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Evaluating the body temperature of horses is an essential tool for monitoring horse health and biosecurity in groups of horses. Temperatures of horses and foals are determined most often using rectal thermom-etry. Rectal thermometry has limitations that include safety considerations for horses and humans. Thus, we investigated the agreement between a noncontact infrared thermometer (NCIT) and a rectal digital thermometer in 142 horses and 34 foals. For each horse and foal, measurements using the NCIT were collected from the forehead (n = 2) or neck (n = 1) and with a rectal digital thermometer (n = 1). Al-though the NCIT demonstrated good reliability (i.e. repeatability of measurements), a large negative bias (nearly 2 degrees F (-16.7 degrees C) in adult horses and > 3 degrees F (-16.1 degrees C) in foals) was observed between readings from the NCIT and the rectal thermometer in healthy horses. Although horses with febrile illness were not included in the study, our results indicate that the large and inconsistent bias observed with the NCIT indicates that these devices will not be a suitable substitute for rectal thermometry for obtaining valid estimates of core body temperature in horses.(c) 2023 Published by Elsevier Inc.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Non-contact Infrared Thermometer for Monitoring Population Temperature Infected with COVID-19
    Mabrouki, Jamal
    Azrour, Mourade
    Boubekraoui, Amina
    Dhiba, Driss
    El Hajjaji, Souad
    [J]. ADVANCED INTELLIGENT SYSTEMS FOR SUSTAINABLE DEVELOPMENT (AI2SD'2020), VOL 1, 2022, 1417 : 985 - 995
  • [32] Impact of measuring distance and exposure to cold outdoor environment on the temperature measurement using a non-contact infrared thermometer
    Peng, Rui
    Huang, Yuanshen
    Zhu, Xuejun
    Li, Xueying
    Li, Hang
    [J]. CHINESE MEDICAL JOURNAL, 2022, 135 (01) : 121 - 122
  • [33] Impact of measuring distance and exposure to cold outdoor environment on the temperature measurement using a non-contact infrared thermometer
    Peng Rui
    Huang Yuanshen
    Zhu Xuejun
    Li Xueying
    Li Hang
    [J]. 中华医学杂志(英文版), 2022, 135 (01) : 121 - 122
  • [34] Can a non-contact infrared thermometer be used interchangeably with other thermometers in an adult Emergency Department?
    Duncan, Alison L.
    Bell, Anthony J.
    Chu, Kevin
    Greenslade, Jaimi H.
    [J]. AUSTRALASIAN EMERGENCY NURSING JOURNAL, 2008, 11 (03) : 130 - 134
  • [35] Clinical accuracy of non-contact infrared thermometer from umbilical region in children: A new side
    Apa, Hursit
    Gozmen, Salih
    Keskin-Gozmen, Sukran
    Aslan, Fatma
    Bayram, Nuri
    Devrim, Ilker
    [J]. TURKISH JOURNAL OF PEDIATRICS, 2016, 58 (02) : 180 - 186
  • [36] Correlation between superficial body temperatures measured with an infrared thermometer in alpacas
    Vilela, Jorge L.
    Ascue, Jorge
    Callan, Milagros
    Goycochea, Gianella
    Jauregui, Andrea
    Miranda, Almendra
    Montalvo, Pamela
    Serna, Alisson
    Sandoval, Aranza
    Solis, Enrique
    Veramendi, Frank
    [J]. JOURNAL OF ANIMAL SCIENCE, 2019, 97 : 463 - 463
  • [37] Measurement of body temperature in 300 dogs with a novel noncontact infrared thermometer on the cornea in comparison to a standard rectal digital thermometer
    Kreissl, Hannah
    Neiger, Reto
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2015, 25 (03) : 372 - 378
  • [38] Comparison of infrared ear thermometer derived and equilibrated rectal temperatures in estimating pulmonary artery temperatures
    Rotello, LC
    Crawford, L
    Terndrup, TE
    [J]. CRITICAL CARE MEDICINE, 1996, 24 (09) : 1501 - 1506
  • [39] An open-source non-contact thermometer using low-cost electronic components
    Mnati, Mohannad Jabbar
    Chisab, Raad Farhood
    Al-Rawi, Azhar M.
    Ali, Adnan Hussein
    Van den Bossche, Alex
    [J]. HARDWAREX, 2021, 9
  • [40] Comparison of non-contact infrared forehead thermometer to standard temperature measurement in neonatal intensive care unit patients
    Can, Emrah
    Bulbul, Ali
    Uslu, Sinan
    Nuhoglu, Asiye
    [J]. TURK PEDIATRI ARSIVI-TURKISH ARCHIVES OF PEDIATRICS, 2010, 45 (03): : 257 - 263