Assessment of the 4-meter walk test test-retest reliability and concurrent validity and its correlation with the five sit-to-stand test in chronic ambulatory stroke survivors

被引:8
|
作者
Cabanas-Valdes, Rosa [1 ]
Garcia-Rueda, Laura [2 ]
Salgueiro, Carina [1 ,5 ]
Perez-Bellmunt, Albert [3 ]
Rodriguez-Sanz, Jacobo [3 ]
Lopez-de-Cells, Carlos [4 ]
机构
[1] Univ Int Catalunya, Fac Med & Hlth Sci, Physiotherapy Dept, Sant Cugat Del Valles, Barcelona, Spain
[2] Univ Int Catalunya, PhD Program, Sant Cugat Del Valles, Barcelona, Spain
[3] Univ Int Catalunya, Basic Sci Dept, Actium Funct Anat Res Grp, Campus St Cugat, Sant Cugat Del Valles, Barcelona, Spain
[4] Fundacio Inst Univ recerca Atencio Primaria Salut, Barcelona, Spain
[5] Clin Neurorehabil, Sant Cugat Del Valles, Barcelona, Spain
关键词
4-meter walking test; 10-meter walking test; Sit to stand; Stroke; Gait speed; 5 times sit to stand; 4-MWT; 10-MWT; Reliability; Concurrent validity; GAIT SPEED; PERFORMANCE; DISTANCE; PREDICTOR; MOBILITY; HEALTHY; PEOPLE;
D O I
10.1016/j.gaitpost.2023.01.014
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: The 4-meter walk test (4-MWT) is a widely used measure to assess gait speed in the elderly but has not been validated for stroke survivors to date. Objectives: To assess the test-retest reliability and concurrent validity of the 4-MWT compared to the 10-meter walk test (10-MWT) as a measure of gait speed in chronic post-stroke. Secondary outcome measure: to assess the correlation of both gait measures with the 5 times sit-to-stand test (5TSTS).Methods: A cross-sectional observational study was conducted. Reliability was assessed by intraclass correlation coefficient (ICC2,1), standard error of measurement (SEM) and minimal detectable change (MDC-95%). Bland & Altman analysis was used to quantify agreement between the 4-MWT and the 10-MWT. Two consecutive walking trials of the 4-MWT and 10-MWT followed by 5TSTS were performed all on the same day. A single researcher made all measurements.Results: Thirty-six chronic ambulatory post-stroke (average age 58.56 +/- 11.28 years) were analyzed at their self-selected walking speed with a dynamic start. The 4-MWT showed excellent concurrent validity and test-retest reliability: ICC2.1 = 0.991 (95% CI: 0.983, 0.996); SEM= 0.032 and MDC-95% = 0.090 m/second) with a strong positive correlation with the 10-MWT (r = 0.957, p < 0.001). The Bland & Altman analysis showed a concordance of-0.05 m/second bias (p = 0.039) (95% limits of agreement: 0.20 to-0.29 m/second). The paired t-test showed no statistically significant difference in the mean of both walking tests (p < 0.091). How-ever, there was only moderate correlation between the two gait assessments and the 5TSTS.Conclusions: This study indicates excellent test-retest reliability concurrent validity and strong correlation be-tween 4-MWT and 10-MWT with a dynamic start at comfortable speed. The 4-MWT could be used as a measure of gait speed in both outpatients and home settings in chronic ambulatory stroke survivors.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 50 条
  • [31] Test-retest reliability of the 10-meter walk test in ambulatory adults with motor-complete spinal cord injury
    Rini, Dhairiamani
    Senthilvelkumar, Thangavelu
    Noble, Koshy
    Magimairaj, Henryprakash
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2018, 25 (07): : 335 - 339
  • [32] FIVE-REPETITION SIT-TO-STAND TEST: RELIABILITY, VALIDITY AND RESPONSE TO PULMONARY REHABILITATION IN COPD
    Jones, S. E.
    Kon, S. S. C.
    Canavan, J. L.
    Clark, A. L.
    Patel, M. S.
    Dilaver, D.
    Peasey, M.
    Ng, M. G. S.
    Polkey, M. I.
    Man, W. D-C
    THORAX, 2012, 67 : A53 - A53
  • [33] Test-Retest Reliability and Convergent Validity of Piezoelectric Force Plate Measures of Single-Leg Sit-to-Stand Performance in Trained Adults
    Makaraci, Yucel
    Nas, Kazim
    Ruiz-Cardenas, Juan D.
    Gunduz, Kerem
    Aydemir, Mustafa
    Orange, Samuel T.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2023, 37 (12) : 2373 - 2380
  • [34] Workplace Sitting Breaks Questionnaire (SITBRQ): an assessment of concurrent validity and test-retest reliability
    Pedisic, Zeljko
    Bennie, Jason A.
    Timperio, Anna F.
    Crawford, David A.
    Dunstan, David W.
    Bauman, Adrian E.
    Salmon, Jo
    BMC PUBLIC HEALTH, 2014, 14
  • [35] Workplace Sitting Breaks Questionnaire (SITBRQ): an assessment of concurrent validity and test-retest reliability
    Zeljko Pedisic
    Jason A Bennie
    Anna F Timperio
    David A Crawford
    David W Dunstan
    Adrian E Bauman
    Jo Salmon
    BMC Public Health, 14
  • [36] Five-times-sit-to-stand test in children with cerebral palsy: Reliability and concurrent validity
    Kumban, Wannisa
    Amatachaya, Sugalya
    Emasithi, Alongkot
    Siritaratiwat, Wantana
    NEUROREHABILITATION, 2013, 32 (01) : 9 - 15
  • [37] Five Times Sit-to-Stand Test in people with non-specific chronic low back pain—a cross-sectional test–retest reliability study
    Anıl Özüdoğru
    Mehmet Canlı
    İsmail Ceylan
    Şafak Kuzu
    Halil Alkan
    Başak Çiğdem Karaçay
    Irish Journal of Medical Science (1971 -), 2023, 192 : 1903 - 1908
  • [38] The test-retest reliability and concurrent validity of the 3-m backward walk test and 50-ft walk test in community-dwelling older adults
    Ozden, Fatih
    Ozkeskin, Mehmet
    Bakirhan, Serkan
    Sahin, Sevnaz
    IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (02) : 921 - 928
  • [39] Reaching performance scale for stroke - Test-retest reliability, measurement error, concurrent and discriminant validity
    Subramanian, Sandeep K.
    Banina, Melanie C.
    Turolla, Andrea
    Levin, Mindy F.
    PM&R, 2022, 14 (03) : 337 - 347
  • [40] Submaximal exercise in persons with stroke: Test-retest reliability and concurrent validity with maximal oxygen consumption
    Eng, JJ
    Dawson, AS
    Chu, KS
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (01): : 113 - 118