Test-Retest Reliability and Convergent Validity of Piezoelectric Force Plate Measures of Single-Leg Sit-to-Stand Performance in Trained Adults

被引:3
|
作者
Makaraci, Yucel [1 ]
Nas, Kazim [1 ]
Ruiz-Cardenas, Juan D. [2 ]
Gunduz, Kerem [3 ]
Aydemir, Mustafa [3 ]
Orange, Samuel T. [4 ,5 ]
机构
[1] Karamanoglu Mehmetbey Univ, Fac Sports Sci, Dept Coaching Educ, Karaman, Turkiye
[2] Univ Catolica Murcia, Physiotherapy Dept, Fac Hlth Sci, Murcia, Spain
[3] Karamanoglu Mehmetbey Univ, Inst Hlth Sci, Dept Sports Sci, Karaman, Turkiye
[4] Newcastle Univ, Sch Biomed Nutrit & Sport Sci, Fac Med Sci, Newcastle Upon Tyne, Tyne & Wear, England
[5] Newcastle Univ, Newcastle Univ Ctr Canc, Newcastle Upon Tyne, Tyne & Wear, England
关键词
reliability; validity; functional strength; kinetic chain; limb symmetry index; lower extremity; unilateral jump; FUNCTIONAL PERFORMANCE; ASYMMETRY; STRENGTH; BALANCE; MUSCLE; POWER; VELOCITY; ABILITY;
D O I
10.1519/JSC.0000000000004489
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The single-leg sit-to-stand (STS) test has emerged as a promising method of assessing lower-limb functional strength and asymmetry. However, the reliability of its performance parameters on a force plate has not been explored. This study examined the test-retest reliability and convergent validity of the single-leg STS test performed on a piezoelectric-based force plate in trained subjects. Thirty trained male adults (age: 21.4 +/- 1.7 years) performed 3 separate single-leg STS days of testing to assess both intraday and interday reliability. Performance parameters included STS time, ground reaction force (GRF), and center of pressure (CoP) sway velocity. The relationship between single-leg STS parameters and unilateral countermovement jump (CMJ) variables was assessed for convergent validity. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were calculated for reliability analyses, and convergent validity was assessed with Spearman's correlation coefficient (rho). In the dominant leg, single-leg performance parameters showed moderate-to-excellent intraday reliability (ICC = 0.65-0.90, CV = 4.3-11.2%) and moderate interday reliability (ICC = 0.54-0.74, CV = 5.8-13.5%). In the nondominant leg, all single-leg STS performance parameters showed good intraday (ICC = 0.79-0.86, CV = 3.8-9.8%) and interday reliability (ICC = 0.75-0.82, CV = 4.6-9.7%). STS times in the dominant and nondominant legs were inversely related to unilateral CMJ velocity (rho = -0.47 and -0.38, respectively). CoP sway velocity in the nondominant leg showed positive correlations with unilateral CMJ power and velocity (rho = 0.38 and 0.54, respectively). In conclusion, the force plate-based single-leg STS test provides reliable measures of STS time, GRF, and CoP sway velocity in trained adults and could be used to assess lower-limb function and asymmetry.
引用
收藏
页码:2373 / 2380
页数:8
相关论文
共 50 条
  • [1] TEST-RETEST RELIABILITY OF SIT-TO-STAND PERFORMANCE MEASURES WITH A PENDANT-WORN ACCELEROMETER
    Zhang Wei
    Regterschot, G. Ruben H.
    Zijlstra, Wiebren
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2012, 20 : S180 - S181
  • [2] Test-retest reliability of sensor-based sit-to-stand measures in young and older adults
    Regterschot, G. Ruben H.
    Zhang, Wei
    Baldus, Heribert
    Stevens, Martin
    Zijlstra, Wiebren
    GAIT & POSTURE, 2014, 40 (01) : 220 - 224
  • [3] INTER-RATER AND TEST-RETEST RELIABILITY OF TWO NEW SINGLE LEG SIT-TO-STAND TESTS
    Waldhelm, Andy
    Gubler, Coral
    Sullivan, Katie
    Witte, Chris
    Buchheister, Devin
    Bartz-Broussard, Jacob
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2020, 15 (03): : 388 - 394
  • [4] Test-Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults
    Jerez-Mayorga, Daniel
    Huerta-Ojeda, Alvaro
    Javier Chirosa-Rios, Luis
    Guede-Rojas, Francisco
    Guzman-Guzman, Iris Paola
    Intelangelo, Leonardo
    Miranda-Fuentes, Claudia
    Delgado-Floody, Pedro
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (13)
  • [5] Validity and Test-Retest Reliability of a Smartphone App for Measuring Rising Time, Velocity, Power, and Inter-Limb Asymmetry During Single-Leg Sit-to-Stand Test in Female-Trained Athletes
    Makaraci, Yucel
    Nas, Kazim
    Gunduz, Kerem
    Uysal, Abdullah
    Orange, Samuel T.
    Ruiz-Cardenas, Juan D.
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2024, 28 (04) : 391 - 400
  • [6] Test-retest reliability and convergent validity of attention measures
    Fernandez-Marcos, Tatiana
    de la Fuente, Cristina
    Santacreu, Jose
    APPLIED NEUROPSYCHOLOGY-ADULT, 2018, 25 (05) : 464 - 472
  • [7] Test-Retest Reliability and Validity of 1-Minute Sit-to-Stand Test in Patients With Chronic Heart Failure
    Tanriverdi, Aylin
    Kahraman, Buse Ozcan
    Ozpelit, Ebru
    Savci, Sema
    HEART LUNG AND CIRCULATION, 2023, 32 (04): : 518 - 524
  • [8] TEST-RETEST RELIABILITY OF THE FIVE-REPETITION SIT-TO-STAND TEST: A SYSTEMATIC REVIEW OF THE LITERATURE INVOLVING ADULTS
    Bohannon, Richard W.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (11) : 3205 - 3207
  • [9] Test-Retest Reliability and Concurrent Validity of the 30 second Sit to Stand Test in Adolescents
    Robinson, Katie J.
    Lubans, David R.
    Mavilidi, Myrto F.
    Ortega, Francisco B.
    Riley, Nicholas
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2024, 28 (01) : 109 - 118
  • [10] Test-retest reliability of 4 single-leg horizontal hop tests
    Ross, MD
    Langford, B
    Whelan, PJ
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2002, 16 (04) : 617 - 622