Assessment of the 4-meter walk test test-retest reliability and concurrent validity and its correlation with the five sit-to-stand test in chronic ambulatory stroke survivors

被引:8
|
作者
Cabanas-Valdes, Rosa [1 ]
Garcia-Rueda, Laura [2 ]
Salgueiro, Carina [1 ,5 ]
Perez-Bellmunt, Albert [3 ]
Rodriguez-Sanz, Jacobo [3 ]
Lopez-de-Cells, Carlos [4 ]
机构
[1] Univ Int Catalunya, Fac Med & Hlth Sci, Physiotherapy Dept, Sant Cugat Del Valles, Barcelona, Spain
[2] Univ Int Catalunya, PhD Program, Sant Cugat Del Valles, Barcelona, Spain
[3] Univ Int Catalunya, Basic Sci Dept, Actium Funct Anat Res Grp, Campus St Cugat, Sant Cugat Del Valles, Barcelona, Spain
[4] Fundacio Inst Univ recerca Atencio Primaria Salut, Barcelona, Spain
[5] Clin Neurorehabil, Sant Cugat Del Valles, Barcelona, Spain
关键词
4-meter walking test; 10-meter walking test; Sit to stand; Stroke; Gait speed; 5 times sit to stand; 4-MWT; 10-MWT; Reliability; Concurrent validity; GAIT SPEED; PERFORMANCE; DISTANCE; PREDICTOR; MOBILITY; HEALTHY; PEOPLE;
D O I
10.1016/j.gaitpost.2023.01.014
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: The 4-meter walk test (4-MWT) is a widely used measure to assess gait speed in the elderly but has not been validated for stroke survivors to date. Objectives: To assess the test-retest reliability and concurrent validity of the 4-MWT compared to the 10-meter walk test (10-MWT) as a measure of gait speed in chronic post-stroke. Secondary outcome measure: to assess the correlation of both gait measures with the 5 times sit-to-stand test (5TSTS).Methods: A cross-sectional observational study was conducted. Reliability was assessed by intraclass correlation coefficient (ICC2,1), standard error of measurement (SEM) and minimal detectable change (MDC-95%). Bland & Altman analysis was used to quantify agreement between the 4-MWT and the 10-MWT. Two consecutive walking trials of the 4-MWT and 10-MWT followed by 5TSTS were performed all on the same day. A single researcher made all measurements.Results: Thirty-six chronic ambulatory post-stroke (average age 58.56 +/- 11.28 years) were analyzed at their self-selected walking speed with a dynamic start. The 4-MWT showed excellent concurrent validity and test-retest reliability: ICC2.1 = 0.991 (95% CI: 0.983, 0.996); SEM= 0.032 and MDC-95% = 0.090 m/second) with a strong positive correlation with the 10-MWT (r = 0.957, p < 0.001). The Bland & Altman analysis showed a concordance of-0.05 m/second bias (p = 0.039) (95% limits of agreement: 0.20 to-0.29 m/second). The paired t-test showed no statistically significant difference in the mean of both walking tests (p < 0.091). How-ever, there was only moderate correlation between the two gait assessments and the 5TSTS.Conclusions: This study indicates excellent test-retest reliability concurrent validity and strong correlation be-tween 4-MWT and 10-MWT with a dynamic start at comfortable speed. The 4-MWT could be used as a measure of gait speed in both outpatients and home settings in chronic ambulatory stroke survivors.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 50 条
  • [21] 4-meter walk test in patients with Parkinson's disease: A reliability and validity study
    Ozkan, Taskin
    Soke, Fatih
    Ataoglu, Nigar Esra Erkoc
    Karakoc, Selda
    Gulsen, Cagri
    Kocer, Bilge
    Comoglu, Selim Selcuk
    Kaplan, Funda
    Bora, Hatice Ayse Tokcaer
    GAIT & POSTURE, 2025, 119 : 87 - 92
  • [22] Test-Retest Reliability and Minimal Detectable Change in Chester Step Test and 1-Minute Sit-to-Stand Test in Long COVID Patients
    Sevillano-Castano, Ana Isabel
    Peroy-Badal, Renata
    Torres-Castro, Rodrigo
    Canuelo-Marquez, Ana Maria
    Rozalen-Bustin, Manuel
    Modrego-Navarro, Angel
    De Sousa-De Sousa, Luis
    Ramos-Alvarez, Juan Jose
    Mate-Munoz, Jose Luis
    Garcia-Fernandez, Pablo
    APPLIED SCIENCES-BASEL, 2023, 13 (14):
  • [23] Test-Retest Reliability of Five Times Sit to Stand Test (FTSST) in Adults: A Systematic Review and Meta-Analysis
    Munoz-Bermejo, Laura
    Adsuar, Jose Carmelo
    Mendoza-Munoz, Maria
    Barrios-Fernandez, Sabina
    Garcia-Gordillo, Miguel A.
    Perez-Gomez, Jorge
    Carlos-Vivas, Jorge
    BIOLOGY-BASEL, 2021, 10 (06):
  • [24] The Reliability and Validity of the Timed Up & Go Test and the 30-S Sit-To-Stand Test Performed via Tele-Assessment in Ambulatory Patients with Stroke
    Tutuneken, Yunus Emre
    Cirak, Yasemin Buran
    Kardes, Kubra
    Isikci, Burcu
    Binbuga, Ramazan
    Cetrefli, Emre
    Sarili, Mehmet
    Oz, Recep Tayyip
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2024, 28 (03) : 236 - 243
  • [25] Concurrent validity and test-retest reliability of the Virtual Peg Insertion Test to quantify upper limb function in patients with chronic stroke
    Bernadette C. Tobler-Ammann
    Eling D. de Bruin
    Marie-Christine Fluet
    Olivier Lambercy
    Rob A. de Bie
    Ruud H. Knols
    Journal of NeuroEngineering and Rehabilitation, 13
  • [26] Concurrent validity and test-retest reliability of the Virtual Peg Insertion Test to quantify upper limb function in patients with chronic stroke
    Tobler-Ammann, Bernadette C.
    de Bruin, Eling D.
    Fluet, Marie-Christine
    Lambercy, Olivier
    de Bie, Rob A.
    Knols, Ruud H.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2016, 13
  • [27] INTER-RATER AND TEST-RETEST RELIABILITY OF TWO NEW SINGLE LEG SIT-TO-STAND TESTS
    Waldhelm, Andy
    Gubler, Coral
    Sullivan, Katie
    Witte, Chris
    Buchheister, Devin
    Bartz-Broussard, Jacob
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2020, 15 (03): : 388 - 394
  • [28] Test-retest reliability, concurrent validity and correlates of the two-minute walk test in outpatients with alcohol use disorder
    Vancampfort, Davy
    Kimbowa, Samuel
    Basangwa, David
    Hallgren, Mats
    Van Damme, Tine
    Rosenbaum, Simon
    Mugisha, James
    ALCOHOL, 2021, 90 : 74 - 79
  • [29] Correction: The five times sit-to-stand test: safety, validity and reliability with critical care survivors’s at ICU discharge
    Thiago Araújo de Melo
    Fernando Silva Guimarães
    José Roberto Lapa e Silva
    Archives of Physiotherapy, 13
  • [30] Reliability and validity of the five-repetition sit-to-stand test in adult kidney transplant recipients
    Huang, Katherin S.
    O'Connor, Ellen
    Tuffnell, Rachel
    Lindup, Herolin
    Macdougall, Iain C.
    Greenwood, Sharlene A.
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2018, 25 (04): : 158 - 166